6 720 610 602 GB (03.02)
4
Details of the appliance
1
Details of the appliance
1.1
EC Declaration of Conformity
This appliance is in accordance with the applicable
requirements of the Gas Appliance Directive, Boiler
Efficiency Directive, Electromagnetic Compatibility
Directive and the Low Voltage Directive.
1.2
Standard package
•
Gas condensing combination boiler for central heat-
ing and domestic hot water
•
Control panel cover
•
Wall mounting frame
•
Room thermostat TR2
•
Clamp for securing flue duct kit
•
Fixings (screws etc.)
•
Set of documentation for appliance
•
Pre-plumbing manifold
•
Condensate drain pipe
•
Filling loop.
1.3
Description of appliance
•
Wall-mounted appliance, siting not dependent on
room size
•
Natural gas models are low-emission appliances
•
Multifunction display
•
Bosch Heatronic control system with integrated tex-
tdisplay for servicefunctions and faults
•
3-channel - digital timer for one heating circuit
•
Variable pump
•
Automatic ignition
•
Modulating control
•
Full safety systems incorporating Bosch Heatronic
with flame ionisation monitoring, solenoid valves and
temperature sensors
•
Concentric flue/air duct with testing point for
CO
2
/CO
•
Regulated speed fan
•
Pre-mix burner
•
Temperature control for central heating
•
Temperature sensor in domestic hot water
•
Safety temperature limiter in 24 V electrical circuit
•
Relief valve, pressure gauge, expansion vessel
•
Flue gas temperature limiter (105 °C)
•
Hot water priority circuit
•
Motorised 3-way valve
•
Plate-type heat exchange
•
Condensate Trap.
PIN
CE-0085 BL0507
Category UK
II
2H 3P
Appliance Type
C
13
, C
33
Table 1