VENTILATION (continued)

Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2.  Ventilation fitted under, or
within immediate vicinity of the appliance must not be used as it may adversely effect performance of the
ODS system. The appliance MUST NOT be installed in a bedroom, bathroom or any sleeping area. For
Republic of Ireland, see relevant rules in force.  The appliance should not be installed within 500mm of any
air vent.

UNPACKING THE APPLIANCE

Remove the outer packaging, remove any instructions or fixing kits. 
Read ALL these instructions before continuing to unpack or install this appliance.
Lift off the remaining packaging components and remove the contents of the box.
Check that the components supplied correlate with the component checklist.  Please dispose of all the
packaging materials at your local recycling centre.

COMPONENT CHECKLIST

QUANTITY

DESCRIPTION

1

Firebox and burner assembly

Set of manufacturers instructions

1

Decorative frame assembly

1

Pair of side panels

1

Screw and wall plug pack

1

Rubber grommet

1

Fitting template

GAS SUPPLY ROUTES 

There are four possible entry points for the gas
supply pipework to enter the appliance firebox.
These entry points are ‘knock out’ type holes. 

Non-concealed gas connections may be made
using the entry points at either end of the firebox
or the one in the bottom of the firebox. A con-
cealed gas connection may be made using the
knock out hole in the centre back of the firebox.
Select the most appropriate entry point and knock
out the relevant hole 
No more than 1.5m of 8mm diameter pipe must be used to avoid unnecessary pressure drops.

If a concealed gas connection is to be made, the supply pipe should always be sleeved through walls and
floors using the shortest possible route. 

For concealed supply pipe routing, pipes must (where possible) be vertical and providing there is sufficient
wall thickness available, they should be placed in pipe chases. Horizontal pipe runs should be avoided.
Prior to chasing a solid wall, an inspection should be made to note the proximity of any cables/sockets out-
lets which may already be buried. 

Pipes must be secured using suitable clips and protected against corrosion. Ideally factory finished pro-
tected pipework and fittings should be used. Joints should be kept to a minimum and compression fittings
must not be used. The pipework installation must be tested for soundness before any protection is applied
and/or the pipework and fittings are buried.

4

5.0

5.1

6.0

4.1

Содержание Berkshire L30G

Страница 1: ...British Fires Berkshire MODEL L30G INSTALLATION AND USER INSTRUCTIONS All instructions must be handed to user for safekeeping Revision A 08 06 Country s of destination GB IE ...

Страница 2: ...Berkshire ...

Страница 3: ...t be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room vol ume in ft3 by 35 3 This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heat ing present The appliance must not be installed in a bedroom bathroom or any sleeping area The appliance does not require a flue system of any ty...

Страница 4: ... ciently ventilated space A minimum of 100cm2 15 5 in2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibility of draughts entering the room via the air vent we recommend the use of Black Hole or Vortex type vents featuring internal baffles It should be noted that heaters create warm air currents These currents move heat t...

Страница 5: ...oom in a home however there are exceptions and the appliance may not be used in the following rooms Bedrooms or areas which are mainly used for sleeping Bathrooms or areas where large amounts of steam are likely to be generated Installation in living rooms is common however other rooms such as kitchens dining rooms and hall ways are permitted providing a suitable natural gas supply is available an...

Страница 6: ...e positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moder...

Страница 7: ...ework to enter the appliance firebox These entry points are knock out type holes Non concealed gas connections may be made using the entry points at either end of the firebox or the one in the bottom of the firebox A con cealed gas connection may be made using the knock out hole in the centre back of the firebox Select the most appropriate entry point and knock out the relevant hole No more than 1...

Страница 8: ...ugs tak ing care to leave the screws protruding approximately 10mm from the wall Now hang the appliance onto these screws through the two keyhole shaped holes in the two upper brackets on the back panel of the appli ance Insert the lower fixing screws into the lower wall plugs through the corresponding fixing brackets in the lower part of the back panel Do not tighten fully Before tightening the w...

Страница 9: ... If under any circumstances the piezo electric spark fails the pilot cannot be lit manually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main burner pipe next to the brass restrictor connector Release the setting pressure test point screw and attach a U gauge Light the fire on the HIGH setting To commission the appliance the burner pressure must...

Страница 10: ...l assemblies from the protective packaging and fit onto the sides of the firebox as shown Insert the M6 retaining screws in the sides of the firebox and ensure they are unscrewed approximately 2mm so the keyhole shaped holes may engage and the sides can be hooked on Insert a screwdriver through the holes in the right hand side panel to access the two M6 fix ing screws designated a in the diagram a...

Страница 11: ...etailed in section 8 4 13 Check the purpose provided ventilation is un obstructed 14 Light the fire and test setting pressures 15 Check safe operation of the appliance For specific servicing instructions see relevant sections SERVICING THE BURNER UNIT AND GAS ASSEMBLY Firstly remove the decorative frame glass facia assembly as described in section 8 4 Remove the inner glass panel and disconnect th...

Страница 12: ...played by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per million ppm terms In order to calculate the combustion ratio for the appliance CO CO2 it is first necessary to express both gas concentrations in terms of percentage To convert from parts per milli...

Страница 13: ... tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR ...

Страница 14: ... indicator bracket Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See rele vant section for further details on clearances to combustibles No combustible materials or flooring should protrude onto the hearth if fitted This appliance incorporates a combustion mo...

Страница 15: ... or discolouration may occur over time The appliance must not be positioned vertically within 100 mm of a carpeted floor rugs or fabric materi als of any kind This dimension is measured vertically to the bottom of the appliance firebox Clearances to non combustibles Non combustible surfaces are defined as brick metal marble concrete etc and also a number of man made materials impervious to flame I...

Страница 16: ...window has been opened cre ating a draught then pilot disturbance could be the problem and removal of the draught should resolve this The appliance can then be re lit in accordance with the previous section If pilot disturbance is not the cause then the ODS safety system may be in operation Switch the appliance OFF call in your installer to check the appliance and ventilation Remedial work must be...

Отзывы: