Страница 3: ...nd freeze mode Lock function to avoid unwanted altering of the settings White balance adjustment to perfectly match the colors of several projectors Default factory settings user settings can be saved loaded 3pin DMX in outputs and Neutrik TRUE1 PowerCON in outputs for easy daisy chaining Fan cooling for longer LED life BEFORE USE Before you start using this unit please check if there s no transpo...
Страница 4: ...ged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropriate and certified safety cable when installing the unit In order to prevent electri...
Страница 5: ...r exit the setup menu button used to go to the next menu option or to decrease a parameter value button used to go to the previous menu option or to increase a parameter value ENTER button used to select a menu option or confirm a setting Remark to rotate the display over 180 press the button while the standard display is shown 7 HANGING BRACKET with nuts for the use of the optional Briteq Omega B...
Страница 6: ...ch of people and outside areas where persons may walk by or be seated Before rigging make sure that the installation area can hold a minimum point load of 10times the device s weight Always use a certified safety cable that can hold 12times the weight of the device when installing the unit This secondary safety attachment should be installed in a way that no part of the installation can drop more ...
Страница 7: ...s are preserved when the unit is disconnected from the mains To select any of the functions press the MENU button until the required function is shown on the display or use the buttons to browse the menu Select the function with the ENTER button Use buttons to change the values Once the required value is selected press the ENTER button to confirm ...
Страница 8: ...se buttons to select the desired playback speed from 01 very slow to 99 fast Once the correct value is shown on the display you have to press the ENTER button to confirm Use buttons to select the desired R Repetitions from 01 to 99 Once the correct value is shown on the display press the ENTER button to save it EFFECT MODE Used to set the desired effect mode while used as master Press the MENU but...
Страница 9: ...ess the ENTER button the display shows the value 050 255 for RED change with buttons Press the ENTER button the display shows the value 050 255 for GREEN change with buttons Press the ENTER button the display shows the value 050 255 for BLUE change with buttons Press the ENTER button the display shows the value 050 255 for WHITE change with buttons Once you have set the desired levels press the EN...
Страница 10: ...e ENTER button Use buttons to select YES NO Press the ENTER button to confirm USER was selected Use buttons to select LOAD SAVE Press the ENTER button to confirm Use buttons to select YES NO Press the ENTER button to confirm SAVE was selected the current settings of the setup menu are saved to memory LOAD was selected the previously saved settings are loaded Default factory settings PARAMETER name...
Страница 11: ...mode The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and all the connected units Pin layout XLR 3pin Pin1 GND Pin2 Negative signal Pin3 Positive signal To prevent strange behavior of the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain Never use Y splitter cables t...
Страница 12: ...the master dimmer MASTER DIM if necessary Refer to chapter HOW TO SETUP to learn how to set the menu options B Two or more units in master slave setup Connect the units together Refer to the chapter electrical installation to learn how to do this Select one of the standalone options AUTO RUN EFF MODE or STATIC COLOR in the first projector of the chain This Master unit will send all the information...
Страница 13: ...ked All screws used for installing the device and any of its parts should be tightly fastened and may not be corroded Housings fixations and installations spots ceiling truss suspensions should be totally free from any deformation When an optical lens is visibly damaged due to cracks or deep scratches it must be replaced The mains cables must be in impeccable condition and should be replaced immed...
Страница 14: ... consumption 129 Watt Power connections Neutrik PowerCON TRUE1 16A Power linking capacity DMX connections 3pin XLR male female DMX channels used 3 modes 4 6 7ch Lamp LED 120W RGBW Standard Beam Angle No lens measured beam angle 35 field angle 77 Lens beam angles 35 lens measured beam angle 33 field angle 51 15 lens measured beam angle 13 field angle 22 IP Rating IP65 Size see drawing Weight 4 8 kg...