ENGLISH
OPERATION MANUAL
BRITEQ
®
7/8
BT-BUBBLEFOG
11 CHANNEL MODE
CH
Function
Value
Details
CH 1
FOG
000-005
OFF
006-255
ON
→
from low volume to high volume
CH 2
BUBBLES
000-005
OFF
006-255
ON
CH 3
FAN
000-005
OFF
006-255
ON
→
from low speed to high speed
CH 4
DIMMER
000-255
MANUAL COLOR settings
CH 5
RED
000-255
CH 6
GREEN
000-255
CH 7
BLUE
000-255
CH 8
AMBER
000-255
CH 9
STROBE
000-015
Strobe OFF
016-255
Strobe (slow to fast)
CH 10
COLOR
MACRO
000-015
NO color
015-024
Red
025-045
Green
046-066
Blue
067-087
Amber
088-108
Light Blue
109-129
Yellow
130-150
Purple
151-171
White
172-213
Color Fade with speed control 172=Slow to 213=Fast
214-255
Color Scroll with speed control 214=Slow to 255=Fast
CH 11
Bubble
Cleaning
000-005
OFF
006-255
Cleaning mode ON
OVERHEAD RIGGING
IMPORTANT
The unit must always be installed so that the bottom of the unit is perfectly horizontal. The
unit must not be inclined forward, otherwise the bubble fluid will leak.
Important:
The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials should
be used, the installed device should be inspected regularly for safety.
•
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
•
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed
at least 50cm
from surrounding walls.
•
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
•
Before rigging make sure that the installation area can hold a minimum point load of
10times the device’s
weight.
•
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
•
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
•
Don’t cover any ventilation openings as this may result in overheating.
•
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
Содержание B04751
Страница 1: ...Other languages can be downloaded from WWW BRITEQ LIGHTING COM ENGLISH Operation Manual Version 1 0...
Страница 2: ......
Страница 11: ......
Страница 12: ......