TH115-AF-G
B
-10
21
ENG
LISH
Display range
: 0°C to 70.0°C (32°F to 158°F)
Ambient setpoint range (A/AF modes)
: 5.0°C to 30.0°C (40°F - 86°F)
Floor setpoint range (F mode)
: 5.0°C to 40.0°C (40°F - 104°F)
Floor limit range (AF mode)
: 5.0°C to 40.0°C (40°F - 104°F)
Resolution
: 0.5°C (1°F)
GFCI
:
1
5 mA
Heating cycle length
: 15 minutes
Data protection
: In the event of a power failure, most settings are saved. Only the time and Daylight
Saving Time must be set if the power failure lasts more than 6 hours. The thermostat will return to the
mode that was active prior to the power failure.
Certification
: c CSA us
Technical Specifications
Supply
Maximum Load (resistive only)
Wiring
Current
Power
120 VAC, 60Hz
15 A
1800 W
4 wires, double pole
240 VAC, 60Hz
15 A
3600 W
4 wires, double pole