Britannia K7088ASC - 70 Скачать руководство пользователя страница 4

Installation

Height above hotplates

For best performance we suggest that the hood is installed at a distance between 65cm to75cm from
the hotplate surface. Under no circumstances should the hood be installed lower than 65cm above the
hotplate surface.

Ducting information

This hood is designed for ducting out, i.e. duct to an outside wall.To obtain the best possible extraction
performance use 150mm diameter ducting.Wherever possible utilise rigid circular pipe or “Mega duct”
ducting - both types are available via your Britannia dealer. Do not use expanding concertina type
ducting as this is not smooth on the interior and can cause air flow restrictions. Do not use ducting
that has a smaller diameter than 150mm as this will reduce extraction rates and can increase noise
levels. Please note ducting kits and ducting components are optional accessories and have to be ordered
- they are not supplied with the hood.

Maximum length of ducting run

4 metres with 1 x 90 degree bend

3 metres with 2 x 90 degree bends

2 metres with 3 x 90 degree bends

Note: the shorter the ducting run and the least number of bends gives the best extraction performance.

Warning: Any ducting used must be fire retardant.

Unpacking the hood

On some models components are packed inside the polystyrene protection pieces.

Do not throw away the box and packaging until installation is fully completed.

Installation

ATTENTION:
The appliance should be installed by a qualified electrician or competent person.

1

Before fixing the hood install the ducting run for air evacuation to the outside. See fig. 1 . Ducting can
be run through the rear wall or through the ceiling.

2

Turn off electricity before preparing a suitable power supply. For the electrical connection requirements
follow the details on page 2.

3

Remove the metal grease filters. See fig. 2

3

90 degree bend

Code DUCT/690

Pipe connector

Code DUCT/693

One metre
ducting kit

Comprising: one
metre length pipe,
wall vent and 90
degree bend.

Code DUCT/2609

One metre
length pipe

Code DUCT/1100-6

Two metre
length pipe

Code DUCT/1200-6

One metre and two
metre length pipes can be
cut to the desired length

Wall vent with
gravity flaps

Code DUCT/6900

Combination of 6” (150mm) circular
pipe and flat channel (220mm x 90mm)
which is ideal for running on top of
wall units or between ceiling joists.

Megaduct kit 

Code DUCT/2652B

Horizontal bend

Code DUCT/950

Megaduct Ducting Kit

horizontal
bend

350

1000

1000

1000

Содержание K7088ASC - 70

Страница 1: ...USER INSTRUCTIONS PRE PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODEL K7088ASC 70 90 100 120CM ...

Страница 2: ... When installed between adjoining wall cabinets the wall cabinets must not overhang the hob hotplate The following applies when ducting out If the room where the cooker hood is to be used contains a fossil fuel burning appliance such as a gas or oil central heating boiler then its flue must be of the room sealed or balanced flue type This hood is not suitable for use in a room where any open flue ...

Страница 3: ...internal house wiring and the terminations labelled LOAD are for connection for the appliance WARNING THIS APPLIANCE MUST BE EARTHED Important The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminal...

Страница 4: ...ves the best extraction performance Warning Any ducting used must be fire retardant Unpacking the hood On some models components are packed inside the polystyrene protection pieces Do not throw away the box and packaging until installation is fully completed Installation ATTENTION The appliance should be installed by a qualified electrician or competent person 1 Before fixing the hood install the ...

Страница 5: ...rs generated by the cooking process When the sensor detects vapours etc the hood automatically switches itself on to the first speed Every 10 seconds the internal microprocessor monitors the data being received from the sensor and changes speed if necessary When the hood no longer detects vapours etc the hood continues to operate for a further few minutes to ensure all residual odours are eliminat...

Страница 6: ...motor speed and is also used to turn the hood off Button D is also used to reset the Filter Alarm and start the countdown for the next 30 hours of operation After cleaning the grease filters simply press Button D whilst the central segment of display window C is illuminated or is flashing and this will reset the filter alarm E Button E is used to turn the hood on at the last speed set and to incre...

Страница 7: ...6 1 2 3 4 5 6 7 8 ...

Страница 8: ...stic use only 4 Any service work will generally entail removal of the telescopic flue assembly to access key components including the motor If the flue assembly has been boxed in by means of a bridging shelf or any type of furniture this must be removed prior to our engineer s visit Before calling for service please check the following 1 Is there a power failure Turn on the appliance to check the ...