Britannia K7088ASC - 70 Скачать руководство пользователя страница 3

Maintenance and service

This appliance can be a fire hazard if the grease filters are not cleaned in accordance with instructions.

Always insist on genuine spare parts.

Under no circumstances should you attempt to repair the appliance yourself. Repairs carried out by
inexperienced persons may cause injury or a more serious malfunction.

In the event of service being required for your cooker hood please contact the service helpline.

Any service work will generally entail removal of the telescopic flue assembly to access key
components including the motor. If the flue assembly has been boxed in by means of a bridging shelf or
any type of furniture this must be removed prior to our engineer’s visit.

2

Electrical connections

Important: Ensure that the electricity supply is switched off
before connecting.

Your appliance must be connected to fixed wiring via the use of a
double pole switched fused spur outlet with at least 3mm contact
separation. (See technical data for fuse rating).
We strongly recommend the appliance is connected by a qualified
electrician who is a member of the N.I.C.E.I.C. or Corgi who will
comply with the I.E.E. and any local regulations.

Note:

The terminology “double pole” means that both the live and

neutral supplies are switched and disconnected at the same time.

The terminations labelled SUPPLY are for the internal house wiring and
the terminations labelled LOAD are for connection for the appliance.

WARNING - THIS APPLIANCE
MUST BE EARTHED

Important:

The wires in this mains lead are

coloured in accordance with the following code:-
Green/Yellow = Earth, Blue = Neutral, Brown = Live

As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in
your spur box, proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal which is marked with
the letter ‘E’ or by the earth symbol or coloured green or green and yellow.The wire which is coloured
blue must be connected to the terminal which is marked with the letter ‘N’ or coloured black.The wire
which is coloured brown must be connected to the terminal which is marked with the letter ‘L’ or
coloured red.

Technical

SPECIFICATION

Technical Data

Fuse rating:

5 AMP

*

**

MODEL K7088

SPEED

1     2     3    4

Air capacity cubic 

metres per hour  *

300 470 630 750

Pressure PA mmH

2

O

34

41

45

46

Input - watts

125 160 200 250

Noise level - dbA **

40

49

56

59

Performance data according to Standard EN61591,
Free air delivery.
Noise level according to Standard IEC60704-2-13 
method.

Finish 

Stainless Steel

Size 

700mm, 9

00mm, 1000mm or 1200mm wide

Controls

Electronic

Air outlet

150mm diameter

Illumination

2 x halogen lamps 20 watts

Motor

1 x 250watts (4 speeds)

Total wattage

290 watts

Mains supply

230 volts 50 Hz

Connection

via a 13 amp fused spur outlet fused at 5 amps

285 440 600 700

36 43

46

47

160 190 215 245

51 58

66

69

Содержание K7088ASC - 70

Страница 1: ...USER INSTRUCTIONS PRE PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODEL K7088ASC 70 90 100 120CM ...

Страница 2: ... When installed between adjoining wall cabinets the wall cabinets must not overhang the hob hotplate The following applies when ducting out If the room where the cooker hood is to be used contains a fossil fuel burning appliance such as a gas or oil central heating boiler then its flue must be of the room sealed or balanced flue type This hood is not suitable for use in a room where any open flue ...

Страница 3: ...internal house wiring and the terminations labelled LOAD are for connection for the appliance WARNING THIS APPLIANCE MUST BE EARTHED Important The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminal...

Страница 4: ...ves the best extraction performance Warning Any ducting used must be fire retardant Unpacking the hood On some models components are packed inside the polystyrene protection pieces Do not throw away the box and packaging until installation is fully completed Installation ATTENTION The appliance should be installed by a qualified electrician or competent person 1 Before fixing the hood install the ...

Страница 5: ...rs generated by the cooking process When the sensor detects vapours etc the hood automatically switches itself on to the first speed Every 10 seconds the internal microprocessor monitors the data being received from the sensor and changes speed if necessary When the hood no longer detects vapours etc the hood continues to operate for a further few minutes to ensure all residual odours are eliminat...

Страница 6: ...motor speed and is also used to turn the hood off Button D is also used to reset the Filter Alarm and start the countdown for the next 30 hours of operation After cleaning the grease filters simply press Button D whilst the central segment of display window C is illuminated or is flashing and this will reset the filter alarm E Button E is used to turn the hood on at the last speed set and to incre...

Страница 7: ...6 1 2 3 4 5 6 7 8 ...

Страница 8: ...stic use only 4 Any service work will generally entail removal of the telescopic flue assembly to access key components including the motor If the flue assembly has been boxed in by means of a bridging shelf or any type of furniture this must be removed prior to our engineer s visit Before calling for service please check the following 1 Is there a power failure Turn on the appliance to check the ...

Отзывы: