13
Step E - Connect Tubes (cont.)
CONNECT YELLOW TUBE FROM REVERSE
OSMOSIS ASSEMBLY TO STORAGE TANK
1
. Locate the 3/8” yellow tube and cut one end square. See
Fig. 16.
2
. Insert all the way into the yellow collet fitting on the
Reverse Osmosis filter assembly. See Figs. 17, 18 & 21.
3
. Route the other end of this tube to the fitting on top of the
storage tank. See Fig. 21.
4
. Cut tube square and to length. See Fig. 16.
5
. Do not connect at this time. This will occur in the sanitizing
step.
CONNECT GREEN TUBE FROM COLD WATER
SUPPLY PIPE TO REVERSE OSMOSIS ASSEMBLY
1
. Locate the 1/4” green tube and cut one end square. See
Fig. 16.
2
. Connect to cold water supply fitting. See Fig. 6.
3
. Route the other end of this tube to the green collet fitting on
the Reverse Osmosis filter assembly. See Fig, 21
4
. Cut tube square and to length. See Fig. 16.
5
. Insert all the way into the fitting. See Figs. 17 & 18.
6
. Pull on the tube to be sure it is held firmly in the fitting.
CONNECT BLUE TUBE FROM REVERSE OSMOSIS
FAUCET TO REVERSE OSMOSIS ASSEMBLY
1
. Locate the 3/8” blue tube attached to the faucet. Fig. 21.
2
. Route the loose end of this tube to the blue collet fitting on
the Reverse Osmosis filter assembly. See Fig. 21.
3
. Cut tube square and to length. See Fig. 16.
4
. Insert all the way into the fitting. See Figs. 17 & 18.
5
. Pull on the tube to be sure it's held firmly in the fitting.
CONNECT BLACK TUBE FROM REVERSE
OSMOSIS FAUCET TO DRAIN ADAPTOR
1
. Locate the 3/8" black tube attached to the faucet. Fig 21.
2
. The loose end needs to be attached to the quick connect
fitting on the sink drain adaptor.
3
. Cut this tube as needed to route it as straight as possible,
without loops, dips, or kinks.
4
. Cut the end of the tube square. See Fig. 16.
5
. Insert all the way into the fitting. See Figs. 17 & 18.
6
. Pull on the tube to be sure it is held firmly in the fitting.
RED TUBE TO REVERSE OSMOSIS FAUCET
The red tube connection was completed in the faucet
assembly steps.
NOTE: Codes in the state of Massachusetts
require installation by a licensed plumber
and do not permit the use of saddle valves.
If you live in the state of Massachusetts,
review plumbing code 248-CMR of the
Commonwealth of Massachusetts before
proceeding with the installation.
NOTE: Tube colors
match collet colors.
Tube Connections
FIG. 21
Tubing Connector
Drain
Adaptor
3/8” BLACK
Tubing
Sink
P–Trap
3/8
” B
LU
E
1/
4”
R
ED
1/4”
GR
EEN
3/8”
YELL
OW
HOT COLD
Water Supply
Fitting
RED
YELLOW
GREEN
BLUE
Reverse Osmosis
Assembly