9 Technical Data
PURITY C ilter system with ilter cartridge
Operating pressure
2 bar to max. 8.6 bar
Water intake temperature
4 °C to 30 °C
Ambient
temperature during
operation
4 °C to 40 °C
storage/transport
–20 °C to 50 °C
Water inlet and outlet connection
G3/8” or John Guest 8 mm
Filter system
C25 Quell
ST
C50 Quell
ST
C150 Quell
ST
C300 Quell
ST
C500 Quell
ST
C1100 Quell
ST
Flow rate with 1 bar pressure loss
160 l/h
160 l/h
145 l/h
140 l/h
140 l/h
150 l/h
Nominal low
30 l/h
60 l/h
60 l/h
60 l/h
100 l/h
100 l/h
Pressure loss at nominal low
0.1 bar
0.25 bar
0.25 bar
0.25 bar
0.5 bar
0.5 bar
Empty ilter cartridge volume
0.85 l
1 l
1.9 l
2.9 l
5.4 l
8.7 l
Weight
dry
0.8 kg
1.0 kg
1.8 kg
2.8 kg
4.6 kg
7.7 kg
wet
1.2 kg
1.6 kg
2.8 kg
4.2 kg
6.9 kg
12.5 kg
Comparable capacity*
170 l
435 l
1,278 l
2,066 l
4,125 l
8,670 l
Dimensions
(Width/
Depth/
Height)
Filter system
(ilter head with
ilter cartridge)
119 mm/
108 mm/
219 mm
119 mm/
108 mm/
268 mm
117 mm/
104 mm/
419 mm
125 mm/
119 mm/
466 mm
144 mm/
144 mm/
557 mm
184 mm/
184 mm/
557 mm
Filter cartridge
108 mm/
108 mm/
210 mm
108 mm/
108 mm/
259 mm
104 mm/
104 mm/
410 mm
119 mm/
119 mm/
457 mm
144 mm/
144 mm/
548 mm
184 mm/
184 mm/
548 mm
Installed dimensions
(vertical installation with
wall mounting bracket)
137 mm/
130 mm/
219 mm
137 mm/
130 mm/
268 mm
137 mm/
128 mm/
419 mm
137 mm/
136 mm/
466 mm
144 mm/
148 mm/
557 mm
-
Operating position
Horizontal or vertical