18
EN
3.3 Liability Exclusion
Installation and cartridge exchanges must be performed precisely in accordance with the instructions
in this manual. BRITA shall not be held liable for any damage, including subsequent damage, arising
from the incorrect installation or use of the product.
3.4 Speciic Safety Information
•
Water used as intake water for the PURITY C water ilter system must be of drinking water
quality. The BRITA water ilter system is only suitable for cold water use within the water
intake temperature range stated in Chapter 9.
•
If there are oficial instructions to boil tap water, the ilter system must be decommissioned.
When the requirement to boil water comes to an end, the ilter cartridge must be replaced
and the connections cleaned.
•
For hygiene reasons, the ilter material of the cartridge is subjected to a special treatment
with silver. A small quantity of silver, which is harmless to health, may be released into the
water. This is in compliance with the World Health Organisation (WHO) recommendations
for drinking water.
•
It is generally recommended to boil tap water for certain groups of people (e.g. people
with weakened immune systems, babies). This also applies to iltered water.
•
Note for people with kidney disease or dialysis patients: During the ilter process the
potassium levels may increase slightly. If you suffer from kidney disease and/or have to
stick to a special potassium diet, we recommend you consult your doctor beforehand.
•
The water iltrate is classiied in Category 2 according to EN 1717.
•
BRITA recommends not to decommission the ilter system for long periods. If the BRITA
PURITY C ilter system is not used for several days, we recommend that the ilter system
be lushed with the volume of water indicated in the table below.
Filter cartridge
Flushing volume after
2–3 days stagnation
Flushing volume after 4 weeks
stagnation
PURITY C25*
1.4 litres
14 litres
PURITY C50
2 litres
20 litres
PURITY C150
3 litres
30 litres
PURITY C300
6 litres
60 litres
PURITY C500
10 litres
100 litres
PURITY C1100
18 litres
180 litres
PURITY C1000 AC
1 litre
10 litres
*available only in Spain, France, Italy
•
The ilter system must not be opened or dismantled during operation. The ilter cartridge must
not be opened.
•
Production date
Production code – ilter head – example: H 3375 01381
3
Production year, this example: 2013
37
Production week, this example: calendar week 37
5
Production day from Monday (1) to Friday (5); this example: Friday
01381
Serial identiication number
Production code ilter cartridge – example: B3224350010
3
Production year, this example:2013
22
Production week, this example: calendar week 22
4
Production day from Monday(1) to Friday (2), this example: Thursday
35
Internal Identiication No. of ilter medium this example: No. 35
0010
Consecutive number of the ilter cartridge, this example the tenth cartridge; reset the day changes
Содержание Purity C Series