4.3 Inserting the ilter cartridge
E
F
•
Pull the lap of the protective cap
7
upwards and remove the protective cap.
•
Note the next exchange date in the date ield on the ilter cartridge resp. on the
FilterManager app
6
.
•
Insert the ilter cartridge
6
in the ilter head
1
in a vertical position.
!
Caution:
The ilter cartridge can only be inserted when the locking handle is open.
Make sure that the ilter cartridge is positioned correctly.
•
Turn the locking handle
2
until you feel it engage.
4.4 Commissioning
G
H
•
Open the water intake and switch on the terminal equipment’s power supply.
•
Operate the lush valve
8
and lush the ilter system until the iltered water runs clear and
without bubbles. At least two empty ilter cartridge volumes must be lushed (Chapter 9).
Note:
When bleeding/lushing, catch water emerging from the lush hose
9
in an
appropriate container.
•
Check system for any leaks.
5 Changing the Filter Cartridge
The PURITY C ilter cartridge must be replaced once the stated capacity has been reached
(see Chapter 6), in accordance with manufacturer’s speciications or no later than 12 months
after commissioning, whichever occurs irst.
!
Caution:
When changing a ilter, examine all remaining parts carefully! Faulty parts must be
replaced and contaminated parts should be cleaned! Read the operating and safety information
(Chapter 3) before changing the cartridge. After storage and transport below 0 °C, the product must
be stored in the open original packaging for at least 24 hours before it is commissioned at the stated
ambient temperatures (Chapter 9) for operation.
Note:
When the locking handle is open, the water supply to the cartridge is interrupted and
short-circuit operation with direct water low from the water inlet
4
to the water outlet
3
is
possible (if necessary, close water intake and switch off power supply to the terminal equipment).
•
Open locking handle
2
.
•
Activate the lush valve
8
and depressurise the system.
•
Remove exhausted ilter cartridge
6
from the ilter head
1
,bearing in mind the weight of the
cartridge.
Note
: The ilter cartridge can be pivoted by 90° in the wall mounting bracket for easy removal.
•
Perform the steps described at 4.3 and 4.4.
6 By-Pass and Capacity Tables
The capacity tables for the PURITY C Quell ST and PURITY Finest C ilter systems are provided on
pages 2–6.
The PURITY C AC and PURITY Fresh C ilter systems have a ilter capacity of 10,000 and 12,000 litres
respectively, regardless of the carbonate hardness and the by-pass set. All intake water is iltered.
Note:
The stated capacities were tested and calculated based on standard application and machine
conditions. This information may vary according to external inluencing factors (for example luctuating
water quality and/or machine type).