Specifications
Inlet Connections: G ½" male thread with 135-165mm centres
Operating Pressure Range: Minimum. 0.2bar, Maximum5.0bar.
Maximum Static Pressure:10.0bar.
Note: Nominally equal (balanced) inlet supply pressures are required for optimum performance. If
pressures are unequal, then apressurereducing valve should be used.
Maximum recommended imbalance between hot and cold supply should not exceed a ratio of 5:1
Maximum Outlet Temperature: Factory pre-set to 38ºC with push button override to46ºC (can
be re-set to suit site conditionsor personalpreference).
SupplyRequirements:
Minimum cold water supply temperature: 5ºC
Maximum cold water supply temperature:25ºC
Maximum hot water supply temperature:80ºC
(a maximum hot water supply of 55-65ºC is recommended for ablutionarypurposes).
Note: The inlet hot water temperature must be at least 10ºCabovethe required blend
temperature (e.g. outlet temperature 43ºC: Minimum hot supply53ºC).
Note: Valves operating outside these conditionscannot be guaranteed by the Scheme to operate
as Type 2valves.