Bristan Joy care Скачать руководство пользователя страница 36

Bristan Group Ltd. 

Birch Coppice Business Park

Dordon

Tamworth

Staffordshire

B78 1SG 

Web: www.bristan.com

Email: [email protected]

A Masco Company

Part Number: FI ES JOY CARE

Issue: D5

Содержание Joy care

Страница 1: ...Stop Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave this document and the Large Print User Guide with the end user Installation I...

Страница 2: ...ign with lots of features Bristan s electric shower collection has been designed to be easy to fit and to use It has also been designed and tested in the UK to all of the relevant British Standards Th...

Страница 3: ...k the flow of water from the showerhead by placing it smothering it on your hand or any other part of your body or foreign object Do not operate the shower if the water stops flowing during use or if...

Страница 4: ...or use in Healthcare and special needs environments the factory set maximum temperature of 41 C must not be altered If the maximum set temperature is altered the shower will still continue to work how...

Страница 5: ...he shower has reached your selected temperature and is ready to use If audible sounds are enabled two short beeps will be heard once the shower is at the correct temperature Phased Shut Down Indicatio...

Страница 6: ...ttom Right hand side Bottom Rear bottom Product Fiche Model JOYTHC85 W JOYTHC95 W JOYTHCK85 W JOYTHCK95 W JOYTHCKH85 W JOYTHCKH95 W Declared Load Profile XS XS XS XS XS XS Water Heating Energy Efficie...

Страница 7: ...st be connected to its own independent electrical supply It must not be connected to a ring main spur power socket or lighting circuit If you don t have a spare fuse way or the rating at the main fuse...

Страница 8: ...ithin the UK Network In domestic installations you must ensure that the electrical supply and existing fuse board are adequately rated Do not turn on the electrical supply until the plumbing has been...

Страница 9: ...ixed or sliding attachment hose retainer so that it can only discharge water at a point not less than 20mm above the spill over level of the bath or shower tray or other fixed appliance If a showerhea...

Страница 10: ...from the wall and drill the wall to suit the wall fixings to be used Fixing Your Shower to the Wall Tips A piece of insulation or masking tape positioned where holes are to be drilled and before mark...

Страница 11: ...entry Bottom right inlet entry Top left inlet entry Rear left inlet entry using a 15mm compression elbow not supplied where NO rear access is available Rear left inlet entry requiring rear access Rear...

Страница 12: ...5 6 Inlet Entry Options The pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left Rear right or Rear left using an elbow as shown on page To top or...

Страница 13: ...he pipe out of the elbow Turn on the water supply and inspect for water leaks at the shower inlet Once inspected turn off the water supply Pressure Relief Device PRD A pressure relief device is design...

Страница 14: ...to pages 7 and 8 Electrical Connection Entry Point Options Select the cable inlet option most suited to your situation Rear bottom left cable entry Rear bottom right cable entry Bottom left cable ent...

Страница 15: ...ciently to allow cables to be directed to the terminal connection block within the unit Note When feeding cable through bottom entry points remove highlighted grey tab on pipe blanking cover if using...

Страница 16: ...ensuring that no cable insulation is trapped under the screws It must be metal to metal Loose connections can result in the cables overheating ensure all terminal screws are fully tightened The suppl...

Страница 17: ...ns electricity supply to the shower Remove front cover Loosen the top and bottom fixing screws and pull front cover from the shower Locate the 8 way Dip switch on the control PCB This is found on the...

Страница 18: ...DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 38 C ON ON ON 39 C OFF ON ON 40 C ON OFF ON 41 C BEAB CARE OFF OFF ON Factory Set 42 C ON ON OFF 43 C OFF ON OFF 44 C ON OFF OFF 45 C...

Страница 19: ...wer On Single short beep Warm up complete Two short beeps Off Single long beep Phased shutdown Short beeps until shower shuts down Error Fault If an error code is displayed on the shower a continuous...

Страница 20: ...staller Settings Audible Sounds ON Switch 4 ON Factory Set OFF Switch 4 OFF ON DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 Need help Give us a call on 0844 701 6273 and speak to one of our trained advi...

Страница 21: ...ide the unit Rotate the temperature control knob to position 5 marked on the front cover Locate cover in position ensuring wiring is not trapped Secure using the 4 cover fixing screws supplied and fit...

Страница 22: ...er installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fix the rail with the large hole on the side shown and wall bracket Check that the rail is hang...

Страница 23: ...missioning Purge Sequence will now resume a 10s no water flows b 30s running water c 10s pulsing water d 30s running water e Shower will display FC permanently on when the Commissioning Purge Sequence...

Страница 24: ...ing the measuring equipment recorded in D1 4 or equipment to the same specification and with the appliance turned off check that a The water supply temperature is within the range 5 to 20 C b The term...

Страница 25: ...next in service test can be deferred to 24 to 28 weeks after commissioning c If small changes e g 1 to 2 K in outlet water temperatures are recorded in both of these periods necessitating adjustment o...

Страница 26: ...ys a delay of a few seconds between you selecting a temperature setting and the selected water temperature starting to flow If the user adjusts the Temperature Control the shower will stabilise to the...

Страница 27: ...tate the spray head one way or the other until it clicks into the desired spray pattern Spray Jet spray Combination spray Note The spray head mode may need to be altered during winter conditions low f...

Страница 28: ...with constant use means you may need to clean your showerhead once a week To ensure continued performance of your electric shower the showerhead needs to be regularly descaled Cleaning the Filter Per...

Страница 29: ...ensure there are no restrictions to the shower Please refer to Cleaning the filter section on page 28 on how how to remove and clean the inlet filter and shower hose filters Once the service has been...

Страница 30: ...kage Remove filter showerhead and clean Refer to Maintenance section on page 28 Outlet water temperature thermistor faulty Call Customer Services on 0844 701 6273 Other Fault Call Customer Services on...

Страница 31: ...Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Guarantee Service Policy Replacement P...

Страница 32: ...gm Pressure Relief Diaphragm x1 1 06 131 400 S Water Inlet Ass Inlet Elbow x1 Swivel Inlet Pipe x1 Filter x1 inc O rings x3 1 07 131 406 S Inlet Elbow Ass Inlet Elbow x1 inc O ring x1 1 08 131 404 S F...

Страница 33: ...33 Spare Parts 5 12 2 13 6 7 8 1 3 4 9 10 11 12 14 15 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors...

Страница 34: ...Ass Matt Chrome 650mm Riser Rail x1 Riser Rail End Caps x2 1 03b 207041 012C 1M 1000mm Riser Rail Ass Chrome 1000mm Riser Rail x1 Riser Rail End Caps x2 1 04a 1625A0A Slider Handset Holder Slider Hand...

Страница 35: ...lease use this space to add any notes you or your installer may have regarding the plumbing system installation of this product Need help Give us a call on 0844 701 6273 and speak to one of our traine...

Страница 36: ...Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com Email enquire bristan com A Masco Company Part Number FI ES JOY CARE Issue D5...

Отзывы: