16
17
Installer Settings
The temperature control has been factory pre-set to 41ºC (at dial
position 5) to meet BEAB care mark. The maximum set temperature
can be adjusted to suit user preference between 38-45ºC. If the
maximum temperature is adjusted from the factory set 41ºC the
shower will no longer meet the BEAB care mark.
To adjust the maximum set temperature follow the steps below
(Refer to page 18 for full switch settings).
Setting the Maximum Temperature
Before removing the front cover to adjust the maximum set
temperature or any user options isolate the mains electricity supply
to the shower.
Remove front cover. Loosen the top and bottom fixing screws
and pull front cover from the shower.
Locate the 8 way Dip switch on the control PCB. This is found
on the back of the front cover.
Set the Dip switch to the required position to set the
maximum temperature and optional user settings. See pages
17-19 for switch positions.
Replace front cover. Position the front cover onto the shower
and secure the top and bottom fixing screws, taking care to
ensure the cable is not trapped.
A01
A02
BEEP En.
TL1
TL2
TL3
NU1
NU2
NU3
DIPSW2
DIPSW1
A02
BEEP En.
TL1
TL2
TL3
NU1
DIPSW1
A01
ON
DIP
ON
DIP
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Need help?
Give us a call on
0844 701 6273
and speak to one of our trained advisors.
Factory settings shown