Brinsea TLC-40 Eco Скачать руководство пользователя страница 3

HD4001 US Issue 01 

MAIN MENU – QUICK REFERENCE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP 

OK  

 

 

C/F 

OK  

 

 

SAVE 

OK  

 

 

 

CANCEL 

OK  

 

 

30.0C 

OK  

-

  

+

 

DISP C  

OK  C  F 

TEMPERATURE.

  

RANGE 20.0 – 40.0°C (68.0 – 104.0°F). 

DEFAULT 30.0°C (86.0°F). 

CELSIUS / FAHRENHEIT DISPLAY.

 

SWITCHES ALL TEMPERATURE FIGURES 

BETWEEN °C AND °F. 

DEFAULT °C. 

SAVE.

 

ALL CHANGES ARE SAVED. RETURN TO 

NORMAL OPERATION SCREEN. 

CANCEL.

 

ALL CHANGES ARE IGNORED. RETURN TO 

NORMAL OPERATION SCREEN. 

PRESS BOTH BUTTONS TO UNLOCK THE MAIN MENU 

SELECT THE OPTION / RETURN TO THE MENU. 

GO FORWARD ONE SCREEN / INCREASE THE VALUE / DISPLAY IN CELSIUS. 

GO BACK ONE SCREEN / DECREASE THE VALUE / DISPLAY IN FAHRENHEIT. 

ALARM HI 

OK  

 

 

ALARM LO 

OK  

 

 

HI  2.0C 

OK  

-

  

+

 

LOW 3.0C 

OK  

-

  

+

 

HIGH TEMPERATURE ALARM.

 RANGE 1.0 – 

5.0°C (1.8 – 9.0°F) ABOVE SET 

BROODER/ICU TEMPERATURE. 

DEFAULT 2.0°C (3.6°F). 

LOW TEMPERATURE ALARM.

 RANGE 1.0 – 

5.0°C (1.8 – 9.0°F) BELOW SET 

BROODER/ICU TEMPERATURE. 

DEFAULT 3.0°C (5.4°F). 

Содержание TLC-40 Eco

Страница 1: ...erson This appliance shall not be used cleaned or maintained by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge without supervision Children shall not play with the appliance Disconnect the brooder ICU from the mains power supply during cleaning Ensure that all electrical parts are kept dry Avoid alcohol based solutions and make sure tha...

Страница 2: ... to the internet please call 1 888 667 7009 Go to www Brinsea com and register as a free member of the Brinsea Email Group to receive the latest news and information such as advance notice about new products special offers exclusive competitions and much more Fig 1 Functional features of the TLC 40 Eco Series II and TLC 50 Eco Series II 40 model shown 2 Quick Reference please read relevant section...

Страница 3: ...CANCEL ALL CHANGES ARE IGNORED RETURN TO NORMAL OPERATION SCREEN PRESS BOTH BUTTONS TO UNLOCK THE MAIN MENU SELECT THE OPTION RETURN TO THE MENU GO FORWARD ONE SCREEN INCREASE THE VALUE DISPLAY IN CELSIUS GO BACK ONE SCREEN DECREASE THE VALUE DISPLAY IN FAHRENHEIT ALARM HI OK ALARM LO OK HI 2 0C OK LOW 3 0C OK HIGH TEMPERATURE ALARM RANGE 1 0 5 0 C 1 8 9 0 F ABOVE SET BROODER ICU TEMPERATURE DEFAU...

Страница 4: ... block 1 Water funnel Fastener and Tool Kit Contents Quantity TLC 40 Quantity TLC 50 Item 2 2 M5 x 16mm countersunk screws 2 2 M5 flat washers 2 2 M5 domed nuts 12 16 M4 x 30mm cap headed screws 12 16 M4 star washers 12 16 M4 nuts 1 1 Door edge strip 1 1 3mm hex key 1 1 4mm hex key 1 1 7mm 8mm wrench 3 1 Please identify each part and check that they are all present and undamaged If there are any p...

Страница 5: ...posed to direct sunlight 4 2 Assemble the cabinet using the tools and fasteners provided Follow the diagrams Do not over tighten fasteners 4 3 The door is hinged at the left as supplied but may be reversed to provide better access if required Fit the top hinge socket to the cabinet using the M5 x 16mm countersunk screws M5 flat washers and M5 dome nuts 4 4 Place the door in the lower hinge and clo...

Страница 6: ... accidental removal by animals 8 9 Air Filter Loosen the bottom hinge cabinet fixings by half a turn so that the hinge becomes free to move Slide the door as far as it will go in the direction of the door latch Tighten the fixings while holding the door Loosen the top hinge cabinet fixing Move it so that the door becomes level in the frame and opens closes freely Tighten the fixings Observe the le...

Страница 7: ...Eco Series II control system utilises a highly accurate calibrated sensor for temperature Be cautious of low cost analogue or digital thermometers when comparing them with the brooder ICU display readings 5 1 NORMAL OPERATION Temperature is continuously displayed The asterisk adjacent to the temperature reading shows when the heater power is on When warming the asterisk will be continuously on onc...

Страница 8: ...s dropped significantly 5 5 HIGH ROOM TEMPERATURE ALARM DISPLAY If the calculated room temperature remains too high for stable temperature control for more than 1 hour a warning is displayed RM and an alarm will sound Press OK to silence the alarm for 30 minutes If the high temperature problem rectifies itself the RM remains on the display to show this has happened Press OK to clear the indicator ...

Страница 9: ...oll to the C F option and press OK to select the C F display screen Press the button to select F or the button to select C Press OK to return to the Main Menu and then scroll down to Save Press OK to save the changes 6 6 TEMPERATURE GUIDELINES FOR BROODING HATCHLING CHICKS As a general rule a newly hatched chick will need a brooder ICU temperature a little lower than incubation temperature about 9...

Страница 10: ... need not be disturbed to fill the water pan Use the funnel provided to pour water through the water fill point in the top of the brooder ICU see fig 1 directly onto the evaporating block and into the water pan Push the funnel down gently into the hole to make sure the water pours directly in Clean up any spilled water from the top of the brooder ICU immediately 7 4 To further increase humidity le...

Страница 11: ...the TLC set to their thermoneutral range The temperature of both the TLC and the animal should be recorded at regular intervals Careful monitoring and observation of the animal should be undertaken to ensure that it is not showing signs of distress i e panting or shivering These animals are also likely to be dehydrated and or shocked hypovolaemic so warming alone will not correct these things and ...

Страница 12: ...th clean water Disinfectant solutions may cause severe cracking of plastic if not correctly rinsed off 10 3 Always clean the TLC brooder ICU before storage and ensure that the unit is totally dry inside and out or damage may occur to the components 10 4 For deeper cleaning the base of the cabinet and the door may be removed by releasing the fasteners See section 4 for assembly guide The cabinet ba...

Страница 13: ...type and rating if necessary 20mm 2A Time delay 250V 11 7 If the problem persists contact your distributor or Brinsea Products Service Dept 11 8 The digital temperature display is individually calibrated during manufacture but may be re calibrated if required In the unlikely event that the accuracy of the temperature display is in doubt please ensure the air filters are cleaned and the heater encl...

Страница 14: ...5 5 x 12 400x300mm 23 5 x 15 5 600x400mm Effective volume 10USgal 40L 26USgal 100L Weight 15lbs 6 7Kg 19lbs 8 7Kg Power consumption 85W typical 150W max 100W typical 150W max Power supply 115V 60Hz or 230V 50Hz as ordered Brinsea Products Inc 704 N Dixie Ave Titusville FL 32796 2017 USA Phone 321 267 7009 Toll Free 1 888 667 7009 Fax 321 267 6090 e mail Sales Brinsea com website www Brinsea com ...