HD4001 US Issue 01
13
11.3
Once the heater area has been dusted the fan assembly must be relocated by ensuring the 4 pegs on the
clear moulding fit into the corresponding holes in the metal base plate.
11.4
ENSURE THE FAN / LED WIRES ARE NOT TOUCHING THE HEATING ELEMENT
11.5
Replace the metal cover so that the water pan slots are at the correct end. Hold the cover in place and fit
the 4 cap-head screws. Do not over-tighten.
11.6
In case of failure first check that the mains power supply is working and that the mains cable connector is
fully engaged in the socket at the rear of the control housing. Check the fuse in the mains inlet on the rear
of the control housing. Replace with a fuse of the same type and rating if necessary (20mm, 2A, Time
delay, 250V).
11.7
If the problem persists contact your distributor or Brinsea Products Service Dept.
11.8
The digital temperature display is individually calibrated during manufacture but may be re-calibrated if
required. In the unlikely event that the accuracy of the temperature display is in doubt please ensure the
air filters are cleaned and the heater enclosure is free of debris following the instructions above. Contact
your distributor or Brinsea directly at [email protected] for further information and advice.
BE CAUTIOUS OF LOW-COST ANALOGUE OR DIGITAL THERMOMETERS.
BRINSEA PRODUCTS LTD USES SOPHISTICATED EQUIPMENT TRACEABLE TO INTERNATIONAL REFERENCE
STANDARDS.
DO NOT DISTURB SENSOR
Fan assembly may be hinged out
on its cables to allow fan and
heater to be dusted with a soft
brush
Fan assembly is located by 4 pegs
in the feet of the clear moulding