WARNING
LP CYLINDER
(NOT SUPPLIED WITH THIS FRYER)
•
The LP (Liquid Propane) cylinder specifically designed to be used with this fryer must
have a 20 lb. (9.1 kg) capacity incorporating a Type 1 cylinder valve and an
over-filling protection device (OPD).
•
DO NOT connect this fryer to an existing #510 POL cylinder valve with Left Hand
threads. The Type 1 valve can be identified with the large external threads on the
valve outlet.
•
DO NOT connect to a LP cylinder exceeding this capacity.
•
DO NOT connect to a LP cylinder that uses any other type of valve connection device.
CYLINDER SPECIFICATIONS:
When purchasing or exchanging a cylinder for your gas fryer, it must be constructed and
marked in accordance with the specifications for LP cylinders of the U.S. Department of
Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for the Transportation of Dangerous Goods as applicable with a listed
over-filling prevention device (OPD).
INSTALLATION INFORMATION:
The installation of this appliance must be in accordance with:
All applicable local codes, or in the absence of local codes, either:
•
National Fuel Gas Code/ANSI Z223.1/NFPA 54
•
Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58
•
Natural Gas and Propane Installation Code CSA B149.1
To check your local codes, see your local LP gas dealer or natural gas company.
This fryer was not intended to be connected to a natural gas supply line.
The cylinder must also be equipped with:
•
A shut-off valve terminating in a Type 1 gas cylinder valve outlet.
•
A Type 1 valve that prevents gas flow until a positive seal is obtained.
•
An arrangement for vapor withdrawal.
•
A collar to protect the cylinder shut-off valve.
•
A safety relief device having direct communication with the vapor space of the
cylinder.
•
A listed over-filling prevention device (OPD).
4