background image

Charging Tips

To Prevent Damage to Spot/flood light and Battery:

Do not attempt to use spot/flood light while charging directly from AC
outlet. Doing so may cause damage to battery and AC charger.

12-volt DC charger/adapter operates from a cigarette lighter receptacle
for charging battery in spot/flood light only while vehicle engine is
running or continuous corded operation with or without battery.

Do not attempt to charge battery pack using both AC an DC chargers
at the same time.

Only use charging devices that are provided with the Q-Beam Max
Million III Rechargeable Spot/Flood Light or its replacements.

For DC Charger/Adapter -

Battery charges only while vehicle engine 

is running. 

For AC Charger -

Allow battery to fully charge. LED indicator on

battery will automatically turn off when battery is fully charged. 

See chart for recommended charge times.

Do not allow battery to completely discharge. A dim light indicates a
low battery. Recharge battery as soon as possible after each use.

Always keep the battery fully charged when not in use.

 

 

 

10

4

6

8

10

 

 

 20

DC Charge

AC Charge

USAGE

(Minutes)

CHARGE TIME (Hours)

Charge Times

Charge times are dependent on usage of the 

product. See chart below for recommended charge times.

6

To Replace Cigarette
Lighter Plug Fuse

Lighter Plug

Lighter Cap

Lighter Plug

Lighter Plug

Lighter Cap

Fuse

Fuse Holder

Lighter Cap

Lighter Cap

Step 1:

Disconnect spot/flood light from power source.

Step 2:

Unscrew cap of lighter plug and pull straight away from fuse.

Step 3:

Pull fuse holder and fuse out of lighter plug. Observe to see if
fuse is burned out.

Note:

Use a 8A fuse only. Fuse is burned out when fuse element is
missing or broken inside glass tube. Replace with new 8A fuse
if fuse element is missing or broken.

Step 4:

Pull fuse out of fuse holder. Insert new fuse into holder.

Step 5:

Insert fuse holder and fuse into lighter plug.

Step 6:

Screw cap onto lighter plug.

INS_800-2380-0_MM3-Bi.qxd  5/16/08  2:16 PM  Page 7

Содержание Q Beam Max Million III

Страница 1: ...MEONE ELSE PARA PREVENIR DAÑO A LA VISTA NUNCA MIRE DENTRO DE LINTERNA CUANDO ESTÁ ENCENDIDA NUNCA APUNTE LUZ A LA CARA DE OTRA PERSONA WARNING ADVERTENCIA WARNING ADVERTENCIA READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS IN THIS MANUAL TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE LEA Y SIGA TODAS LAS ADVERTENCIAS E INSTRUCCIONES DE ESTE MANUAL PARA EVITAR LESIONES CORPORALES O DAÑOS A LA PROPIEDAD...

Страница 2: ... corroded DO NOT allow metal parts to touch metal contacts on battery as this can cause a short circuit and result in a fire DO NOT use an outdoor AC outlet to recharge battery To prevent accidental electrical shock we recommend this product always be charged on a GFCI Ground Fault Circuit Interrupter outlet Only use charging devices that are provided with the Q Beam Max Million III Rechargeable S...

Страница 3: ...use Step 1 Follow charging instructions on page 3 of this manual and allow battery to fully charge Step 2 Depress trigger switch in handle to turn spot flood light ON Release trigger switch to turn spot flood light OFF Step 3 To lock trigger switch to ON depress trigger switch and slide down lock button on side of handle To unlock and turn spot flood light OFF depress trigger and slide lock button...

Страница 4: ...arge times WARNING A damaged battery can leak acid Avoid contact with eyes and skin If contact occurs flush immediately with large amounts of water DO NOT ingest If contact with eyes or ingestion occurs consult physician immediately 3 To Charge 10 4 6 8 10 20 DC Charge AC Charge USAGE Minutes CHARGE TIME Hours Charge Times Charge times are dependent on usage of the product See chart below for reco...

Страница 5: ...r only Step 3 For AC Charger Allow battery to fully charge LED indicator on battery will automatically turn off when battery is fully charged IMPORTANT If battery is not used for more than 90 days remove battery from the spot flood light Charge battery every 2 months to ensure battery does not completely lose charge A completely discharged battery may not recharge properly WARNING A damaged batter...

Страница 6: ...lding the connector firmly with fingers then pulling bulb wire straight out Step 13 To install new bulb grasp the bulb from the metal end DO NOT TOUCH THE GLASS PART and insert into the reflector mounting plate Align the slots in the bulb base with those in the reflector mounting plate Step 14 Replace wire retainer by pinching ends together while pressing down Push ends apart so they catch on the ...

Страница 7: ...attery to completely discharge A dim light indicates a low battery Recharge battery as soon as possible after each use Always keep the battery fully charged when not in use 10 4 6 8 10 20 DC Charge AC Charge USAGE Minutes CHARGE TIME Hours Charge Times Charge times are dependent on usage of the product See chart below for recommended charge times 6 To Replace Cigarette Lighter Plug Fuse Lighter Pl...

Страница 8: ...partes metálicas toquen los contactos de metal en la pila ya que esto podría causar un corto circuito que a su vez podría provocar un incendio NO use un tomacorriente externo de corriente alterna CA para recargar la pila Para evitar un choque eléctrico accidental recomendamos que este producto siempre se cargue en un tomacorriente con interruptor de circuito para conexión a tierra GFCI Sólo use lo...

Страница 9: ...ones de carga de la página 3 de este manual y permita que la pila se cargue totalmente Paso 2 Presione el interruptor de disparo en el mango para ENCENDER la lámpara reflector o de luz concentrada Suelte el interruptor de disparo para APAGAR la lámpara Paso 3 Para trabar el interruptor de disparo en posición ENCENDIDA presiónelo y deslice el botón de bloqueo que está a un lado del mango hacia abaj...

Страница 10: ...os tiempos de carga recomendados ADVERTENCIA Una pila dañada puede dejar salir ácido Evite el contacto con los ojos y la piel Si hay contacto enjuáguese inmediatamente con mucha agua NO lo ingiera Si hubo contacto con los ojos o ingestión consulte a su médico cuanto antes 9 Cómo Cargarla 1 0 4 6 8 1 0 2 0 Carga con CD Carga con CA USO Minutos TIEMPO DE CARGA Horas Tiempos de Carga Los tiempos de c...

Страница 11: ... indicadora LED se encenderá únicamente cuando el cargador CA esté cargando la pila Paso 3 Para cargador CA Permita que la pila se cargue totalmente El indicador LED en la pila se apagará automáticamente cuando la pila se haya cargado totalmente IMPORTANTE Si la pila no se usa por más de 90 días sáquela de la lámpara Cargue la pila cada 2 meses para asegurarse de que no pierda su carga Una pila to...

Страница 12: ... último firmemente con sus dedos y luego jalando el cable de la bombilla directamente hacia fuera Paso 13 Para instalar una nueva bombilla sujétela por el extremo metálico NO TOQUE LA PARTE DE VIDRIO e introdúzcala a la placa de montaje del reflector Alinee las ranuras en la base de la bombilla con las de la placa de montaje del reflector Paso 14 Coloque de nuevo el sujetador de cables comprimiend...

Страница 13: ...a está baja Recárguela tan pronto como le sea posible tras cada uso Siempre conserve la pila totalmente cargada cuando no la use 1 0 4 6 8 1 0 2 0 Carga con CD Carga con CA USO Minutos TIEMPO DE CARGA Horas Tiempos de Carga Los tiempos de carga dependen del uso que se le dé al producto Consulte el diagrama que aparece a continuación para los tiempos de carga recomendados 12 Cómo Cambiar el Fusible...

Страница 14: ...ion garantiza esta lámpara reflector o de luz concentrada Q Beam Max Million III recargable por defectos de materiales o de mano de obra por 1 año a partir de la fecha de compra a su comprador original Las obligaciones de The Brinkmann Corporation que cubre esta garantía se limitan a las siguientes condiciones Esta garantía no cubre la bombilla o pila Esta garantía no cubre lámparas recargables qu...

Отзывы: