background image

EN

ELUM Sp. z o.o.

1A Wilanowska Str., 05-520 Konstancin-Jeziorna, Poland

www.elum24.pl

SAFETY AND MAINTENANCE

To keep the optimal technical parameters of the luminaire the periodical maintenance should be 

carried out. Before cleaning the product, disconnect it from power supply. Ignoring this warning can 

cause danger of electric shock. The housing of the luminaire should be cleaned by generally available 

cleaning supplies and also dried with a soft cloth. Do not use corrosives chemicals and solvents.

 

Do not use stream of water under pressure.

                      This symbol stands for selective collecting of the electrical and electronic equipment, 

therefore, this product cannot be treated as other household’s waste. It has to be left

 

at a special used-equipment collection point. The appropriate dealing with the collection 

of used electrical and electronic equipment is crucial, especially if the equipment 

includes dangerous components which have a negative influence on the environment

 

and on the health of people.

 

Floodlights

INSTALLATION

Installation of the luminaire should be done by the certified and experienced electrician. 

Before starting the installation you must absolutely turn off the main power supply, where 

the luminaire should be connected to, to avoid accidental voltage connection! Electrical 

cables must be connected according to the instruction and regulations in force.

 Performing 

any operations inside the luminaire with the power supply switched on may result in an 

electric shock!

CAUTION!

1.  We reserve the right to apply changes in the construction of the product.

2.  The information included in this document may undergo changes without warning.

Possible changes will be taken into consideration while working with other issues

 

of the instructions for use or complementary documents.

3.  We take no responsibility for faults resulting from non-compliance with the above 

instructions. According to article 568 pt 1 of the Polish Civil Code, the right resulting from

 

a warranty for physical defects are extinct after the lapse of 2 (two) years after delivery

 

of the luminaire to the Buyer.

ALUM

DIMENSIONS (mm)

ALUM 50R, 50W

 

with motion sensor

ALUM 50, 50W

200W

~230V

CRI 80

4000K

25000h

120

o

50/60Hz

50W 100W

-20

+45

C

o

IP

 

65

ALUM 50

ALUM 100

ALUM 200

ALUM 100, 100W

ALUM 200, 200W

A

B

C

C

A

B

Model

A [mm]  B [mm]  C [mm]

ALUM 50

205

192

33

ALUM 100

290

252

40

ALUM 200

390

358

48

Model

A [mm]  B [mm]  C [mm]

ALUM 50R

205

216

45

INSTALLATION AND OPERATING MANUAL

ALUM 50, ALUM 100, ALUM 200 – LED floodlights

ALUM 50R – LED floodlights with PIR motion sensor

TECHNICAL DATA

LUX

+

-

TIME

+

-

SENS

IP

 

44

ALUM 50R

with motion

sensor

CHARACTERISTIC

 

ALUM is a series energy saving LED floodlights with high protection rate IP 65. They are perfect 

for illumination of various objects and surfaces like: buildings elevations, yards, entrances, 

gates, gardens, parking lots, boards, billboards, store windows, interior spaces with conditions 

of increased humidity and pollination level.

Floodlight’s versions named ALUM 50R are equipped with PIR motion sensor. These types 

have IP 44 protection rate.

The ribbed housing of luminaires is made of aluminum casting. The tempered glass shield 

provides high protection rating as well as effective protection of LEDs against mechanical 

impact. Due to metal movable mounting bracket those luminaires are adapted for installation 

with various inclination angles.

 

LED panel with LEDs SMD type is used as the light source in ALUM floodlights, it allows 

significant energy saving comparing to traditional luminaires and keeps the same luminous 

parameters. The light sources of the luminaires are not replaceable, once the light source is 

used up full luminaire should be replaced.

 

Light colour: neutral white (4000K).

Luminaires have a power cable that is lead out of the luminaire through tight gland.

 

T

he lenght of power cable is shown in [Fig.3.].

Terminal block / hermetic cable connector for current ~230V are not included in the set.

 

An advice from qualified person is needed for installation.

 

PIR motion sensor in ALUM 50R floodlights:

  -  motion detection range: 220

o

,

  -  installation height: 2m - 4m,

  -  working temperature: -20

o

C - +45

o

C,

  -  three adjustment ranges: TIME, SENS, LUX.

LUX function - Ambient Light Intensity

The level of light intensity, at which the sensor will be forced to launch the 

lighting, is adjusting with the potentiometer in range from 3 lux to 2000 lux.

The sensor can work in the daytime and at the night when it is adjusted on 

the “sun” position (max). It can work in the ambient light less than 3 lux 

when it is adjusted on the “moon” position (min).

TIME function - Time-Delay

The time of turning the light on by the motion sensor could be adjusted in 

the range from 10sec ±3sec  to 7min±2min, by turning over 

 

the potentiometer from min to max.

SENS function - Detection Distance

 

The detection distance of motion on by the sensor can be adjusted

 

in the range from 2m to 8m (<24

o

C) by turning the potentiometer from 

minium to maximum.

Model

ALUM 50R

ALUM 50 ALUM 100 ALUM 200

Luminaire type

with motion sensor

without motion sensor

Power of the luminaire

50W

50W

100W

200W

Supply voltage

220 ÷ 240V AC

Frequency

50/60Hz

Power factor (cos φ)

0,9

Beam angle

120°

Protection rate

IP 44

IP 65

IP 65

IP 65

Protection class

I

Type of light source

LEDs SMD type

Light colour

neutral white

Correlated colour temperature

4000K

Colour rendering index (CRI)

80

LEDs lifespan*

25 000 hours

Luminous flux of the luminaire**

3500 lm

3500 lm

7000 lm

14000 lm

Ambient temperature

-20°C ÷ +45C

Weight

0,74kg

0,68kg

1,32kg

3,50kg

*

 

provided parameter is based on LEDs manufacturer’s data / **

 

parameter is provided with  ±5%  tolerance margin

1.  Mark and drill properly spaced installation holes on the mounting surface.

 

Screw the floodlight to the mounting surface.

2.  Connect the power cable to terminal block [Fig.1.] or hermetic connector [Fig. 2.], 

accordingly:

 

- phase cable (brown)  to the slot marked “L”,

 

- neutral cable (blue) to the slot marked „N”,

 

- safety cable (yellow-green) to the slot marked         .

 

Recommended hermetic connectors ELGO brand ZH1-3P25, ZH2-3P25.

 

The terminal block and hermetic connector are not included in the set with the 

luminaire.

3.  Set the parameters of motion sensor.

4.  Stabilize the floodlight in chosen position.

Fig.1.

Fig.2.

Fig.3.

Model

A [mm]  B [mm]  C [mm]

ALUM 50R

150

30

8

ALUM 50

150

30

8

ALUM 100

150

30

8

ALUM 200

150

30

8

Lenght of cables (mm).

A

A

C

B

Отзывы: