7K116
TO PROGRAM METER
1. Press function button to scroll to pulses screen.
2. Enter the number of pulses for the model as listed above using the up or down buttons.
3. Press function button to set pulses. (If screen goes blank before you press the function
button, repeat steps 1 & 2).
4. Press function button to scroll to width screen.
5. Enter the width of seeder for the model as listed above using the up or down buttons.
6. Press the function button to set width. (If screen goes blank before you press the function
button, repeat steps 4 & 5).
7. Press function to scroll through screens to check that the correct pulses and width have
been entered.
TO ENTER PASSWORD
1. Press function button to scroll to pass screen.
2. Pick a number and enter it by using the up or down buttons.
3. Press function button to set password; number screen will show (set): Record number - it is
required if you need to disable password.
4. Let screen go blank - password is now entered.
TO DISABLE PASSWORD
1. Press function button to scroll to pass screen - will show (ent).
2. Use up or down button to enter password (number).
3. Press function button to scroll around to pass screen again. Number entered in step 2 will
appear.
4. Press up or down button to enter 0.
5. Press function button; (dis) will appear. Password is now disabled.
MODEL
PULSES PULSES WIDTH
PER
ACRE
PER
1000 sq.’
SLP
SL8
4147
95
8.0
SLP10
SL10
4147
95
10.07
SLP12
SL12
4147
95
12.0
SLP204
1690
39
4.0
SLP206
1690
39
6.0
SLP208
SL208
1528
35
8.0
SLP210
SL210
1528
35
10.0
SLP212
SL212
1528
35
12.0
GLP643
SSLP643
0917
21
5.3
SSPT604
0293
7
5.0
SS8, SS208
SSP8, SSP208
0764
18
8.0
SS10, SS210
SSP10, SSP210
0764
18
10.0
SS12, SS212
SSP12, SSP212
0764
18
12.0
SPECIAL NOTES
• When meter is set to “count” mode in
pulses screen, meter will register only
magnetic wheel revolutions.
• Meter must be in sleep mode (blank
screen) to calculate acres or to count
pulses.
• Count screen must have a value other
than zero (0000) to scroll to other
modes or screens.
• To reset FIELD ACRES screen to zero
(0000), press the up and down buttons
simultaneously.
SETTINGS FOR ELECTRONIC ACRE METER - SUMMARY
6K382
rev 1/25/2000
BOS4S, BOS4F, BOSB4S, BOSB4F
0600
14
4.0
BOS6S, BOS6F, BOSB6S, BOSB6F
0600
14
6.0