9. Schematic representation and list of parts

Num

Component name

Num

Component name

1

ventilation panel

25

air outlet hose

2

base

26

air return hose

3

central panel

27

titanium tube 
to the four-way 
valve E

4

front panel

28

air collection tube 
from the four-way 
valve C to the 
capacitor

5

side panel

29

tube from the 
capillary tubes 
to the liquid 
separator

6

capacitor terminal

30

tube from the filter 
to the capillary tubes

7

rear panel

31

tube from the filter 
to the titanium tube

8

terminal board

32

liquid separator 
assembly

9

rear support rod

33

air connection tube 
assembly

10

rear grid

34

capacitor

11

motor console

35

fan motor

12

side grid

36

fan blade

13

top cover

37

wiring diagram

14

compressor

38

control panel

15

compressor cover

39

controller

16

nut

40

compressor capacitor

17

shock-proof gasket

41

fan capacitor

18

compressor gasket

42

cable terminals

19

nut

43

cable clamp

20

titanium heat 
exchanger in PVC

44

logo

21

electronic 
expansion valve

45

name plate

22

filter

46

spring washer

23

Four-way valve

47

nut

24

four-way valve 
connection

EN

Содержание XHP 100

Страница 1: ...Swimming Pool Heat Pump XHP INSTALLATION AND USER GUIDE Illustrative photo i Read the instructions EN...

Страница 2: ...e the device and to avoid unnecessary injuries Contents 1 Specification 3 2 Performance curves 4 3 Dimensions 5 4 Installation 5 5 Electrical connection 9 6 Initial heat pump start up and its winteriz...

Страница 3: ...dvised pool volume m3 0 15 0 20 25 40 35 60 55 80 60 90 Advised water flux m3 h 4 2 4 2 6 8 4 9 10 2 Water pipe in out spec mm 50 General Data Compressor rotary Air flow horizontal Condenser titanium...

Страница 4: ...T OUTPUT CURVE INPUT curve COP curve HEAT OUTPUT kW INPUT kW COP Air temperature Air temperature Air temperature Swimming pool water temperature C XHP 40 XHP 60 XHP 100 XHP 140 XHP 200 XHP 40 XHP 60 X...

Страница 5: ...50 360 410 410 E 750 930 930 1000 1045 1045 F 210 210 230 340 560 560 G 83 83 83 83 83 83 H 500 550 550 620 695 695 Unit mm 4 Installation 4 1 Installation illustration heat pump water treatment side...

Страница 6: ...ve 3 from to HEAT PUMP Discharge connection to the swimming pool NOTE The manufacturer delivers only the heat pump system Other items shown in the illustration are other necessary components of the wa...

Страница 7: ...the device when installed is situated vertically without any inclination Do not install the device in places where there is contamination corrosive gas or where dirt or fallen leaves accumulate The he...

Страница 8: ...per hour 2 000 BTU per 5 C of the water temperature difference in the swimming pool and the ground around the technology pipes which increases the run time by 3 to 5 To achieve the best exchange of h...

Страница 9: ...mp check whether the electrical mains voltage corresponds to the operating voltage of the heat pump Compressor Fan motor Four way valve Electric expansion valve Transformer OUTPUT3 OUTPUT4 OUTPUT5 RUN...

Страница 10: ...yellow green blue blue blue red GND GND GND GND GND GND blue Ambient temperature sensor Returned coolant temperature sensor Heating coil temperature sensor Water outlet coil temperature sensor Water...

Страница 11: ...with dotted lines is only in some models yellow green yellow green red red red red yellow green yellow green blue blue blue blue blue white blue blue brown blue brown brown yellow OUTPUT4 OUTPUT5 OUTP...

Страница 12: ...ps below 1 Switch on the filtration pump check whether any water is leaking out and check the flow of water through the system 2 Connect the power supply to the heat pump and then press the ON OFF but...

Страница 13: ...mp for intake and outlet of water and allow the water to drain from the heat pump In the winter season it is recommended to fit the disconnected heat pump in a place where temperatures will not fall b...

Страница 14: ...s real time 1 press the button for 5 seconds and enter the operating parameters interface 2 in this interface use the up and down arrows to check the parameters 3 the temperature of the incoming water...

Страница 15: ...ating the defrosting function 30 to 0 C default setting is 7 C Parameter 4 conditions for deactivating the defrosting function 2 to 30 C default setting is 20 C Parameter 5 defrosting function deactiv...

Страница 16: ...electronic expansion valve 18 to 94 default setting 70 5 7 4 How to identify the current mode Parameter B temperature of incoming water Parameter C temperature of outgoing water Parameter D capacitor...

Страница 17: ...temperature of outgoing water capacitor temperature temperature of returned gas ambient temperature current intervals of the electronic expansion valve 2 when the heat pump is off the display shows c...

Страница 18: ...ng press the button again 7 8 Setting the activation of the timer Press the button to set the time for switching on the heat pump and press the up or down arrow to set the interval timing To save this...

Страница 19: ...to 99 C Accurate value setting E Temperature of returned gas 9 to 99 C Accurate value setting F Ambient temperature 9 to 99 C Accurate value setting G Capacitor temperature in the cooling mode H Actu...

Страница 20: ...re or the temperature of incoming water is too low The pump will run automatically during the first stage of the frost protection system Second stage of the frost protection system PP7 The ambient tem...

Страница 21: ...2 The values indicate a fault 3 Controller failure 1 Correct the running mode 2 Replace the defective cable controller with the LED display then check the condition after the change of the running mod...

Страница 22: ...ar panel 31 tube from the filter to the titanium tube 8 terminal board 32 liquid separator assembly 9 rear support rod 33 air connection tube assembly 10 rear grid 34 capacitor 11 motor console 35 fan...

Страница 23: ...rator Four way valve Filter Electronic expansion valve Titanium heat exchanger Compressor Suction valve Watertight casing Control LED display Fan blade Fan motor Plastic water flow switch 10 Spare par...

Страница 24: ...pare parts 2 11 Cabling diagram example XHP 60 manometer high pressure valve fan motor capacitor low pressure valve temperature sensors control unit Panel main controller Compressor capacitor Transfor...

Страница 25: ...pressure valve suction valve and the electronic expansion valve 2 The replacement can only be carried out when the internal pressure of the system equals the normal atmospheric pressure 3 After the f...

Страница 26: ...e disposal of the product after its service life After its service life is over have the product disposed of ecologically by a specialized company Claims and servicing Claims are governed by applicabl...

Страница 27: ......

Страница 28: ......

Отзывы: