Using the + and - keys, select the Channel that you wish 
to program. 

Using the + and - keys, select the Timing entry that you 
wish to program. 

PROGRAM MODE

Program channel
Channel 1

PROGRAM MODE

Program channel     
Channel 1
Entry 1

Program channel, Clear timing entries and Set up system

 

options will require a PIN number 

before allowing access. 

Programming Timing Entries 

(access code protected)

 

Program channel

PROGRAM MODE

Enter PIN number

0---

When selecting one of these options, the following screen 
will be displayed.   
Use the + and - key to enter your 4 digit access code and 
press the ACCEPT key to move on. 
 
During programming, the access code will only be 
required to be entered once, until Program Mode is exited.  
This is done by pressing the ESCAPE key. 

Mode; TIMED (Continuous); 
CYCLIC (Pulsed) 

Channel/Entry Number 

Operational Days 

Start time; HRS:MIN 

Run duration; HRS:MIN:SEC 

ON=00:00:00/00:00:00

 START M------ 00:00

Edit    1/1   CYCLIC

DURATION 00:00:00

CYCLIC mode only 

CYCLE ON time; 
HRS:MIN:SEC 

CYCLE OFF time; 
HRS:MIN:SEC 

Timing entry programming screens 

Содержание Bright-time

Страница 1: ...BRIGHTFLOW CHEMICAL DISPENSING SYSTEMS B926 v1 0 4 CHANNEL REAL TIME CLOCK...

Страница 2: ...in a continuous TIMED mode or a pulsed CYCLIC mode The 4 outputs can be individually selected to be used as volt free Max 6A contacts or to give a 24V DC output Max 0 7A 16W The volt free contact opti...

Страница 3: ...3 NO C GND CH1 CH2 CH3 CH4 NO C GND NO C GND NO C GND 230V Installation Diagram 1 2 24V 0V NO C GND CH1 CH2 CH3 CH4 NO C GND NO C GND NO C GND...

Страница 4: ...C GND NO C GND BRIGHTWELL DISPENSERS 230V L N E 24VDC 0V 24VDC 0V 24VDC 0V 24VDC 0V NO 24VDC when ON C N A GND Ground With the links in place the relevant outputs will supply 24V DC Channel 1 LK1 LK2...

Страница 5: ...ND NO C GND BRIGHTWELL DISPENSERS 230V L N E NO C NO C NO C NO C NO Normally open C Common GND N A With the links removed the relevant outputs will be set to operate as zero volt contacts Channel 1 LK...

Страница 6: ...s the Accept key to enter the program mode menu Scroll through the menu using the and keys Select the required option by pressing the Enter key PROGRAM MODE Program channel View channel PROGRAM MODE P...

Страница 7: ...er PIN number 0 When selecting one of these options the following screen will be displayed Use the and key to enter your 4 digit access code and press the ACCEPT key to move on During programming the...

Страница 8: ...ayed briefly whilst the information is stored WARNING For safety saving will turn off Channel 1 1 If the programmed entry is currently active then it will revert to an off state once edited This warni...

Страница 9: ...ear timing entries Channel 1 Please wait Enabling and Disabling Channels Using the and keys select the Channel that you wish to ENABLE DISABLE PROGRAM MODE Enable channel Channel 1 Using the and keys...

Страница 10: ...urrent time and date pressing ACCEPT to move on PROGRAM MODE Set up system Edit date and time 00 00 dd mm yy Setting the day date and time access code protected Press ACCEPT to edit the date and time...

Страница 11: ...cannot be OVER RIDDEN The OVER RIDE facility allows any one or all of the channels to be reversed in state If the channel is ON then it will be switched OFF and if the channels is OFF then it will be...

Страница 12: ...closure IP66M ABS Supply 230V 50 60Hz Fusing T400mA Maximum Outputs Volt free 250V 6A DC 24V DC 0 7A Clock Accuracy 4 Min Yr Approvals EMC 89 336 EEC EN50081 1 EN50082 1 LVD 72 23 EEC EN60335 1 OVER R...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...44 0 1273 513566 Sales 44 0 1273 511300 Fax 44 0 1273 516134 BENELUX GERMAN OFFICE Brightwell Dispensers Ltd Lonneker Steumke 21 Enschede NL 7524 DN The Netherlands Sales 31 0 53 4344018 Fax 31 0 53...

Отзывы: