Briggs & Stratton Standby Generator Systems Скачать руководство пользователя страница 6

Not for 

Reproduction

6 BRIGGSandSTRATTON.COM

 

CAUTION

 Installing the 15A fuse could cause the 

engine to start at any time without warning 

resulting in minor or moderate injury.

•  Observe that the 15 Amp fuse has been removed from the 

control panel for shipping.

•  DO NOT install this fuse until all plumbing and wiring has 

been completed and inspected.

 

WARNING

 Moving parts could crush and cut. 

Starter and other rotating parts could 

entangle hands, hair, clothing, or 

accessories resulting in serious injury.

•  NEVER operate generator without protective housings, 

covers, or guards in place.

•  DO NOT wear loose clothing, jewelry or anything that 

could be caught in the starter or other rotating parts.

•  Tie up long hair and remove jewelry.
•  Before servicing, remove 15 Amp fuse from control panel 

and disconnect 

Negative

 (

NEG

 or 

-

) battery cable.

 

WARNING

 Hot pressurized coolant could cause serious 

injury.

•  DO NOT open radiator cap when hot.
•  Before servicing, allow coolant to cool.

 

CAUTION

 Excessively high operating speeds could 

result in minor injury and/or equipment damage. 

Excessively low speeds impose a heavy load on generator.

•  DO NOT tamper with governed speed. Generator supplies 

correct rated frequency and voltage when running at 

governed speed.

•  DO NOT modify generator in any way.

NOTICE 

 Improper treatment of generator could damage it 

and shorten its life.

•  Use generator only for intended uses.
•  If you have questions about intended use, contact your 

authorized dealer.

•  Operate generator only on level surfaces.
•  Adequate, unobstructed flow of cooling and ventilating air 

is critical to correct generator operation.

•  The access panels/doors must be installed whenever the 

unit is running.

•  DO NOT expose generator to excessive moisture, dust, 

dirt, or corrosive vapors.

•  Remain alert at all times while working on this equipment. 

Never work on the equipment when you are physically 

or mentally fatigued.

•  DO NOT start engine with air cleaner or air cleaner 

cover removed.

•  DO NOT insert any objects through cooling slots.
•  DO NOT use the generator or any of its parts as a step. 

Stepping on the unit could cause stress and break parts. 

This may result in dangerous operating conditions from 

leaking exhaust gases, fuel leakage, oil leakage, etc.

•  If connected devices overheat, turn them off and 

disconnect them from generator.

•  Shut off generator if: 

 

-electrical output is lost; 

 

-equipment sparks, smokes, or emits flames; 

 

-unit vibrates excessively or makes unusual noises.

NOTICE 

 Exceeding generators wattage/amperage 

capacity could damage generator and/or electrical devices 

connected to it.

•  Start generator and let engine stabilize before connecting 

electrical loads.

Содержание Standby Generator Systems

Страница 1: ...ual Liquid Cooled Generator System This generator is rated in accordance with UL Underwriters Laboratories 2200 stationary engine generator assemblies and CSA Canadian Standards Association standard C...

Страница 2: ...ce This generator system requires professional installation before use The installer should follow the instructions completely Where to Find Us You never have to look far to find support and service f...

Страница 3: ...andby Generator to REDUCE THE RISK OF FIRE 14 Other General Location Guidelines 16 Concrete Slab 16 Access Ports 18 The Gaseous Fuel System 20 Fuel Consumption 21 Fuel Pressure 21 Power Loss 21 Fuel P...

Страница 4: ...ing Parts Electrical Shock Explosion WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm WARNING C...

Страница 5: ...ce the fuel system lines must be properly purged and leak tested After the generator is installed you should inspect the fuel system periodically NO leakage is permitted DO NOT operate engine if smell...

Страница 6: ...running at governed speed DO NOT modify generator in any way NOTICE Improper treatment of generator could damage it and shorten its life Use generator only for intended uses If you have questions abo...

Страница 7: ...ons must strictly comply with all applicable codes industry standards and regulations Owner Responsibilities Read and follow the instructions given in the operator s manual Follow a regular schedule i...

Страница 8: ...ge If loss or damage is noted after delivery separate the damaged materials and contact the carrier for claim procedures Missing or damaged parts are not warranted Shipment Contents The standby genera...

Страница 9: ...control panel to the transfer switch is installed in a separate conduit from high voltage wires unless the insulation rating on all wiring is rated for 600V See Transfer Switch Communication Dipswitch...

Страница 10: ...N o t f o r R e p r o d u c t i o n 10 BRIGGSandSTRATTON COM Page Intentionally Left Blank...

Страница 11: ...ld result in death serious injury headache fatigue dizziness vomiting confusion seizures nausea or fainting Operate this product ONLY outdoors in an area that will not accumulate deadly exhaust gas Ke...

Страница 12: ...to a potentially occupied building or structure By law it is required in many states to have a Carbon Monoxide CO detector in operating condition in homes and other structures occupied by people Carbo...

Страница 13: ...oors ventilation intakes soffit vents crawl spaces open garage doors or other openings where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building or structure...

Страница 14: ...ad clearance from any structure overhang or trees DO NOT place weatherproof enclosure under a deck or other type of structure that may confine airflow USE ONLY flexible fuel line provided Connect prov...

Страница 15: ...tallations with Structure Without a Fire Rating NOTICE The figures below show the minimum installation distances allowed to structures and items listed in legend Standby weatherproof enclosure must ha...

Страница 16: ...enings If prevailing winds will cause blowing or drifting you may need to construct a windbreak to protect the unit Concrete Slab At the appropriate location construct a concrete slab 28 day compressi...

Страница 17: ...Use a spreader bar to ensure that the chains straps or cables DO NOT touch the generator s roof Hooks may be used in the lifting holes in place of the pipe in accordance with OSHA or local lifting re...

Страница 18: ...fuel selector and engine starter E Control Panel Cover field wiring and control wires Each generator is shipped with a set of identical keys These keys fit in the lock on the front and rear removable...

Страница 19: ...2 Secure the panel with two bolts To remove front panel 1 Remove the two bolts H that secure the panel to the unit 2 Lift panel to remove from unit To secure front panel 1 Place panel in unit 2 Secur...

Страница 20: ...s known to occur piping should be protected against freezing The termination of hard piping should include a sediment trap E where condensate is not likely to freeze A minimum of one accessible approv...

Страница 21: ...ing Maximum pressure with engine OFF at No Load is 13 85 in W C Power Loss Air density is less at high altitudes resulting in less available engine power Specifically engine power will decrease 3 for...

Страница 22: ...the open position 3 Press the control board OFF button 4 Remove 15 Amp fuse from control panel 5 Remove the rear panel 6 Locate the fuel selector collar on bottom of fuel regulator A 7 Carefully push...

Страница 23: ...and Line 2 Power connection to transfer switch G Neutral and Ground Connection Connect to transfer switch neutral and ground System Connectors Compare this illustration with your generator to familia...

Страница 24: ...wn schematically and as wiring diagram A complete schematic and wiring diagram can be found later in this manual Neutral is not bonded to ground at generator NOTICE Prior to making connections verify...

Страница 25: ...d terminals installed per terminal supplier s instructions and comply with national electrical codes and local requirements Utility Circuit Connection 240V Utility leads must be routed in conduit The...

Страница 26: ...ity outage OFF Turns off running generator prevents unit from starting and resets any detected faults OFF must be pressed and held for more than 5 seconds in order to reset service codes MANUAL Used t...

Страница 27: ...THE GENERATOR OFF TURNS OFF RUNNING GENERATOR PREVENTS UNIT FROM STARTING AND RESETS ANY DETECTED FAULTS AUTOMATIC MODE NORMAL OPERATING POSITION PRESS AND HOLD BUTTON TO PLACE UNIT INTO AUTOMATIC MO...

Страница 28: ...ate or change these settings follow the steps below IF DURING PROGRAMMING NO BUTTONS ARE PRESSED FOR 30 SECONDS THE CONTROL PANEL WILL AUTOMATICALLY EXIT THE PROGRAM MODE SET DATE SET DATE If set to O...

Страница 29: ...button The following will scroll across the digital display and then move to the next item Run time Date Time Exercise Cycle date and start time The user can press the LEFT ARROW or RIGHT ARROW at an...

Страница 30: ...d region where the generator is being operated Confirm all settings before operating the generator for the first time For advanced menu items press and hold the left arrow right arrow and escape key f...

Страница 31: ...e specifications shown in this chart Battery Specifications BCI Model 26R Volts 12 Volt DC Amps MIN 525 CCA cold cranking amps Type VRLA Valve Regulated Lead Acid Terminal Hardware Post Dimensions MAX...

Страница 32: ...rged This may cause the engine to run roughly for a few minutes 6 Listen for unusual noises vibration or other indications of abnormal operation Check for oil leaks while engine runs 7 Let engine warm...

Страница 33: ...generator will only enter the exercise cycle if the unit is in the AUTO mode and this exact procedure is followed To set the exercise timer NOTICE The generator is set with a default exercise cycle se...

Страница 34: ...N o t f o r R e p r o d u c t i o n 34 BRIGGSandSTRATTON COM Schematic Diagram...

Страница 35: ...N o t f o r R e p r o d u c t i o n 35...

Страница 36: ...N o t f o r R e p r o d u c t i o n 36 BRIGGSandSTRATTON COM Wiring Diagram...

Страница 37: ...N o t f o r R e p r o d u c t i o n 37...

Страница 38: ...N o t f o r R e p r o d u c t i o n 38 BRIGGSandSTRATTON COM NOTES...

Страница 39: ...N o t f o r R e p r o d u c t i o n 39 NOTES...

Страница 40: ...N o t f o r R e p r o d u c t i o n Page Intentionally left Blank...

Отзывы: