Briggs & Stratton SIMPLIPHI SPHI-B-4.9 Скачать руководство пользователя страница 2

E N E R G Y T R A K   U S E R   M A N U A L         |         2

Safety Alert Symbol and Signal Words

This safety alert symbol identifies safety information about hazards that could result 
in personal injury or damage to the system. A signal word 

(DANGER, WARNING, 

or CAUTION)

 is used to indicate the likelihood and the potential severity of injury.  

In addition, a hazard symbol is used to represent the type of hazard.

DANGER

 indicates a hazard which, if not avoided, 

will

 result in death or serious injury.

WARNING

 indicates a hazard which, if not avoided, 

could

 result in death or serious injury.

CAUTION

 indicates a hazard which, if not avoided, 

could

 result in minor or moderate injury.

NOTICE

 indicates information considered important but not hazard-related.

Warranty Statement

The following abbreviated guidelines do NOT encompass all EnergyTrak Warranty details.  Failure to 
adhere to the Warranty and Installation Manual requirements will violate the terms of the Warranty.  
Read the complete Warranty and Installation Manual related to EnergyTrak and its connected 
Energy Solutions products (i.e., SimpliPHI™  Energy Storage System) prior to installation, which can 
be found at 

www.briggsandstratton.com

.

Table of Contents

 

Important Safety Instructions _________________________________________2
Warranty Statement ________________________________________________3
Energy Solutions Product Compatibility _________________________________4
Site Network and Internet Requirements ________________________________5
Getting Started with EnergyTrak for Pros ________________________________6
EnergyTrak Gateway Installation _______________________________________7
EnergyTrak for Pros _________________________________________________9
SimpliPHI ESS Commissioning with EnergyTrak _________________________ 12

Important Safety Instructions

Symbol

Meaning

Symbol

Meaning

Safety alert symbol shows a possible personal 

injury hazard or damage to the system.

Chemical Burn

Read Manual. Failure to obey warnings, 

instructions, installation manual, and 

Operator’s Manual could result in death or 

serious injury.

Toxic Fume

Explosion

Eye Protection

Electric Shock

Hot Surface

Auto-Start

Rotating Parts

Fire

E N E R G Y T R A K   U S E R   M A N U A L         |         3

Содержание SIMPLIPHI SPHI-B-4.9

Страница 1: ...EnergyTrak Install and User Manual for Pros C O N N E C T M O N I T O R C O N T R O L ...

Страница 2: ...lated to EnergyTrak and its connected Energy Solutions products i e SimpliPHI Energy Storage System prior to installation which can be found at www briggsandstratton com Table of Contents Important Safety Instructions__________________________________________2 Warranty Statement_________________________________________________3 Energy Solutions Product Compatibility________________________________...

Страница 3: ...ak Gateway using one of the following Hardwired network connection using an ethernet cable RECOMMENDED or WiFi network connection with a strong signal at the location of the EnergyTrak Gateway All network equipment associated with connecting the EnergyTrak Gateway to the Internet i e router modem network switches should be powered from the critical loads panel so that these systems maintain operat...

Страница 4: ...6 GW 3 GW 9 GW 1 GW 8 GW 2 GW 7 GW 11 Not Included Customer Provided GW 8 Battery CAN Bus Ethernet Cable Cat 5e or Cat 6 1 GW 9 Inverter RS 232 Ethernet Cable Cat 5e or Cat 6 30 meters or less GW 10 Inverter CAN Bus Ethernet Cable Cat 5e or Cat 6 100 meters or less GW 11 Local Area Network Ethernet Cable Cat 5e or Cat 6 100 meters or less GW 12 Battery to Gateway Enclosure Electrical Wires two 2 w...

Страница 5: ...port labeled BMS on the SimpliPHI 6kW Inverter 5 Connect one end of GW 8 to the RJ45 port on GW 1 and the other end to the RJ45 port labeled DEVICE on one of the SimpliPHI 4 9kWh Batteries If there are multiple batteries installed in parallel the installer can connect this to the port on any of the batteries 6 Connect the 3 position connector on GW 2 to the CAN port on the EnergyTrak Gateway 7 Con...

Страница 6: ...gyTrak Gateway From this screen Pro users are able to view greater detail about and remotely edit the configuration of the installed products for any site registered to their account For safety reasons System Owner users are not able to edit the configuration of the ESS but they do have the ability to edit network settings of the EnergyTrak Gateway i e WiFi network settings and toggle the time of ...

Страница 7: ...rid Profile that should be set in the SimpliPHI 6kW Inverter based on the installation Options include IEEE 1547 Default or Off Grid Operating Profile Confirm the appropriate Operating Profile that should be set in the SimpliPHI 6kW Inverter based on the installation See the section below titled Choose Operating Profile for more details Site Info The SimpliPHI ESS will be registered to a Site with...

Страница 8: ...ces More information EnergyTrak uses a Bluetooth connection between the EnergyTrak Gateway and the mobile device running the EnergyTrak app The Bluetooth list will show all available Bluetooth networks that are in range of the mobile device The name of the gateway s Bluetooth network matches its ID which is printed on the label of the gateway If the EnergyTrak Gateway is not in the network list Fo...

Страница 9: ...e to complete This process is NOT reliant on the Bluetooth connection between the mobile device and the gateway so it is okay to take the mobile device out of Bluetooth range go get a snack If the mobile device leaves Bluetooth range once the gateway has begun updating the firmware on the inverter and or battery the firmware update process will continue between the EnergyTrak Gateway and the Simpl...

Страница 10: ...charge to Load when PV absent Enabled Grid Tied Zero Export Parameter Setting Solar Distribution Priority Load Battery Enable Charging Enabled Enable AC Charging Enabled Enable feed to Utility Disabled Enable discharge to Load when PV present Enabled Enable discharge to Load when PV absent Enabled Grid Tied Solar Parameter Setting Solar Distribution Priority Grid Enable Charging Disabled Enable AC...

Страница 11: ...discharge to Load when PV absent AC Charge Time Window AC Support Load Time Window Add System Owner Enter the required information for the System Owner and press the ADD button This will create a new EnergyTrak System Owner user account More information If the email address is NOT associated with an existing EnergyTrak account an email invitation will be sent to the provided email address from ene...

Страница 12: ...nfiguration features can be used to view and validate the settings which have been applied to the system including details about the SimpliPHI ESS Pros are highly encouraged to review this detail and validate the system s operation prior to completing their work Troubleshooting At this point if the SimpliPHI ESS is producing any faults or the system is not operating as intended the technician shou...

Отзывы: