background image

22

BRIGGSandSTRATTON.COM

2. Length of Coverage

B&S warrants to the initial owner and each subsequent
purchaser that the Warranted Parts shall be free from
defects in materials and workmanship which caused the
failure of the Warranted Parts for a period of two years
from the date the engine is delivered to a retail
purchaser.

3. No Charge

Repair or replacement of any Warranted Part will be
performed at no charge to the owner, including
diagnostic labor which leads to the determination that a
Warranted Part is defective, if the diagnostic work is
performed at an Authorized B&S Service Dealer. For
emissions warranty service contact your nearest
Authorized B&S Service Dealer as listed in the “Yellow
Pages” under “Engines, Gasoline,” “Gasoline Engines,”
“Lawn Mowers,” or similar category.

4. Claims and Coverage Exclusions

Warranty claims shall be filed in accordance with the
provisions of the B&S Engine Warranty Policy.
Warranty coverage shall be excluded for failures of
Warranted Parts which are not original B&S parts or
because of abuse, neglect or improper maintenance as
set forth in the B&S Engine Warranty Policy. B&S is not
liable to cover failures of Warranted Parts caused by
the use of add-on, non-original, or modified parts.

5. Maintenance

Any Warranted Part which is not scheduled for
replacement as required maintenance or which is
scheduled only for regular inspection to the effect of
“repair or replace as necessary” shall be warranted as
to defects for the warranty period. Any Warranted Part
which is scheduled for replacement as required
maintenance shall be warranted as to defects only for
the period of time up to the first scheduled replacement
for that part. Any replacement part that is equivalent in
performance and durability may be used in the
performance of any maintenance or repairs. The owner
is responsible for the performance of all required
maintenance, as defined in the B&S Operator’s Manual.

6. Consequential Coverage

Coverage hereunder shall extend to the failure of any
engine components caused by the failure of any
Warranted Part still under warranty.

Emission Information

Engines that are certified to meet the California Air
Resources Board (CARB) Tier 2 Emission Standards must
display information regarding the Emissions Durability
Period and Air Index. The engine manufacturer makes this
information available to the consumer on emission labels.
The engine emission label will indicate certification
information.

The 

Emissions Durability Period

describes the number of

hours of actual running time for which the engine is certified
to be emissions compliant, assuming proper maintenance in
accordance with the Operating & Maintenance Instructions.
The following categories are used:

Moderate:

Engine is certified to be emission compliant for

125 hours of actual engine running time.

Intermediate:

Engine is certified to be emission compliant

for 250 hours of actual engine running time.

Extended:

Engine is certified to be emission compliant for

500 hours of actual engine running time.

For example, a typical walk-behind lawn mower is used 20 to
25 hours per year. Therefore, the 

Emissions Durability

Period

of an engine with an 

intermediate

rating would

equate to 10 to 12 years.

Certain engines will be certified to meet the United States
Environmental Protection Agency (USEPA) Phase 2 emission
standards. For phase 2 certified engines, the Emissions
Compliance Period referred to on the Emissions Compliance
label indicates the number of operating hours for which the
engine has been shown to meet Federal emission
requirements.

For engines less than 225 cc displacement:
Category C = 125 hours
Category B = 250 hours
Category A = 500 hours.

For engines of 225 cc or more displacement:
Category C = 250 hours
Category B = 500 hours
Category A = 1000 hours.

Содержание PowerBoss PowerBOSS 5600 Watt Portable Generator

Страница 1: ...Printed in U S A Manual No 197106GS Revision C 08 02 2007 5600 Watt Portable Generator Operator s Manual BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A...

Страница 2: ...for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand thes...

Страница 3: ...ures and Controls 10 Cord Sets and Receptacles 11 Operation 12 Starting the Engine 12 Connecting Electrical Loads 13 Stopping the Engine 13 Don t Overload Generator 14 Maintenance 15 Maintenance Sched...

Страница 4: ...moderate injury NOTICE indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The manufacturer cannot possibly anticipate eve...

Страница 5: ...stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WHEN ADDING OR DRAINING...

Страница 6: ...ire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed CAUTION Excessively high operating speeds increase ri...

Страница 7: ...he following tools to install these components 13 mm wrench Socket wrench with a 13 mm socket Pliers Safety glasses Install the wheel kit as follows 1 Tip generator so that engine end is up 2 Slide ax...

Страница 8: ...Altitude At altitudes over 5 000 feet 1524 meters a minimum 85 octane 85 AKI 89 RON gasoline is acceptable To remain emissions compliant high altitude adjustment is required Operation without this adj...

Страница 9: ...DO NOT place generator where exhaust gas A could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes...

Страница 10: ...and motor loads D Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area E Data Tag Provides model revision and serial number of generator Please hav...

Страница 11: ...quiring up to 5 600 watts of power 5 6 kW at 23 3 Amps for 240 Volts or two independent 120 Volt loads at 23 3 Amps each The outlet is protected by a push to reset circuit breaker 120 Volt AC 20 Amp D...

Страница 12: ...own during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil protection device If so oil must be at proper level for e...

Страница 13: ...in and turned ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push engine rocker switch to Off position 4 Move fuel valve to Off positio...

Страница 14: ...tor output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additio...

Страница 15: ...rator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or...

Страница 16: ...generator is on a level surface 2 Check oil level as described in Checking Oil Level 3 If needed slowly pour oil into oil fill opening to the point of overflowing at oil fill 4 Replace and tighten oi...

Страница 17: ...Specifications 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the recommended replacement spark plug See Specifications 5 Install spark plug and tighten firmly Servic...

Страница 18: ...ne without partial engine disassembly and the use of special tools For this reason we recommend that you have an authorized service dealer check and adjust valve clearance at recommended intervals see...

Страница 19: ...ded grade See Changing Engine Oil Oil Cylinder Bore Remove spark plug and pour about 1 2 ounce 15 ml of clean engine oil into the cylinder Install spark plug and pull starter handle slowly to distribu...

Страница 20: ...set to Off 2 Fuel Valve is in Off position 3 Dirty air cleaner 4 Out of fuel 5 Stale fuel 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in fuel 9 Flooded 10 Excessively rich f...

Страница 21: ...ur Operating and Maintenance Instructions B S recommends that you retain all your receipts covering maintenance on your small off road engine but B S cannot deny warranty solely for the lack of receip...

Страница 22: ...maintenance or repairs The owner is responsible for the performance of all required maintenance as defined in the B S Operator s Manual 6 Consequential Coverage Coverage hereunder shall extend to the...

Страница 23: ...nd apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not...

Страница 24: ...wer This difference is due to a variety of factors including but not limited to accessories air cleaner exhaust charging cooling carburetor fuel pump etc application limitations ambient operating cond...

Страница 25: ...Generador Port til de 5600 Vatios Manual del Operario BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A...

Страница 26: ...n Montaje de este manual donde encontrar instrucciones para el montaje final Siga las instrucciones al pie de la letra D nde encontrarnos Usted no tendr que ir muy lejos para encontrar el servicio t...

Страница 27: ...er sticas 10 Juegos de cordones y enchufes conectores 11 Operando 12 Encienda el motor 12 Conexi n de cargas el ctricas 13 Parada del motor 13 No sobrecargar el generador 14 Mantenimiento 15 Plan de m...

Страница 28: ...el s mbolo de alerta AVISO indica una situaci n que podr a producir da os en el equipo Siga en todo momento los mensajes de seguridad para evitar o reducir el riesgo de lesiones y de muerte El fabrica...

Страница 29: ...sirvan al generador ADVERTENCIA La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras severas e inclusive la muerte CUANDO ANADA CO...

Страница 30: ...sconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR Utilice un comprobador de buj as homologado NO comprueba la chispa sin la bu...

Страница 31: ...de ruedas conforme a las instrucciones siguientes 1 Dele la vuelta al generador de forma que el motor quede arriba 2 Introduzca el eje A a trav s de los dos soportes de montaje 3 Coloque una rueda B e...

Страница 32: ...orar Gran altitud En altitudes superiores a 1 524 metros 5 000 pies se deber utilizar gasolina con un m nimo de 85 octanos 85 AKI 89 RON Para seguir cumpliendo la normativa sobre emisiones es necesari...

Страница 33: ...puedan acumular o entrar en un edificio que pueda estar ocupado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio...

Страница 34: ...otor Indica el modelo tipo y c digo del motor Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda G Silenciador Apagachispas El silenciador disminuye el ruido del motor y est equi...

Страница 35: ...sencilla que requieren hasta 2 800 vatios de energ a a 23 3 Amperios para 120 Voltios 5 600 vatios de energ a 5 6 kW a 23 3 Amperios para 240 Voltios La salida est protegida por un corto circuito de...

Страница 36: ...seg rese de que la unidad est en una superficie plana y compruebe que el nivel de aceite del cig e al es correcto La unidad puede equiparse con un dispositivo de protecci n de bajo nivel de aceite En...

Страница 37: ...je que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador 3 Sit e el interruptor balanc n en la posici n Off 4 Gire la v lvula de comb...

Страница 38: ...cuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA a ada cargas que sobrepasen...

Страница 39: ...l motor y provocar p rdidas de rendimiento o fallos Asimismo si penetran l quidos en el generador a trav s de las ranuras del aire de refrigeraci n parte del l quido puede permanecer en los huecos y r...

Страница 40: ...aceite indicados Comprobaci n del nivel de aceite Compruebe el nivel de aceite antes de cada uso o cada 5 horas de funcionamiento como m nimo Rellene si es necesario 1 Coloque el generador sobre una...

Страница 41: ...te a mano 8 Limpie los residuos de aceite Servicio del depurador de aire Si se utiliza con un filtro de aire sucio el motor no funcionar correctamente y puede sufrir da os Cambie el filtro de aire cad...

Страница 42: ...tas especiales Por esta raz n le recomendamos que un distribuidor autorizado compruebe y ajuste la holgura de la v lvula siguiendo los intervalos recomendados consulte la secci n Plan de Mantenimiento...

Страница 43: ...grado de aceite recomendado Aceite el di metro interior del cilindro Quite la buj a y vierta aproximadamente 15 ml 1 2 onza de aceite de motor limpio en el interior del cilindro Coloque la buj a y ar...

Страница 44: ...ire sucio 4 Sin gasolina 5 Gasolina vieja 6 El cable de la buj a no est en malas la buj a 7 Buj a defectuosa 8 Agua en la gasolina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La v lvu...

Страница 45: ...sponsable de la correcta realizaci n de las operaciones de mantenimiento que se enumeran en las Instrucciones de uso y mantenimiento B S recomienda conservar todas las facturas relativas al mantenimie...

Страница 46: ...to y durabilidad equivalentes El propietario es responsable del cumplimiento de todas las operaciones de mantenimiento obligatorio que se definen en el manual del operario de B S 6 Cobertura de da os...

Страница 47: ...s sanitarios destinados al mantenimiento de las constantes vitales Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabr...

Страница 48: ...eal Esta diferencia se debe entre otros a los siguientes factores accesorios filtro de aire escape carga refrigeraci n carburador bomba de combustible etc limitaciones de la aplicaci n condiciones amb...