background image

9

System Ground

The generator has a system ground that connects the
generator frame components to the ground terminals on the
AC output receptacles. The system ground is connected to
the AC neutral wire (the neutral is bonded to the generator
frame).

Special Requirements

There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:

• In some areas, generators are required to be registered

with local utility companies.

• If the generator is used at a construction site, there

may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical
system must be made by a qualified electrician. The
connection must isolate the generator power from utility
power or other alternative power sources and must comply
with all applicable laws and electrical codes.

Generator Location

Clearances and Air Movement

Place generator outdoors in an area that will not accumulate
deadly exhaust gas. DO NOT place generator where exhaust
gas (

A

) could accumulate and enter inside or be drawn into a

potentially occupied building. Ensure exhaust gas is kept
away from any windows, doors, ventilation intakes, or other
openings that can allow exhaust gas to collect in a confined
area. Prevailing winds and air currents should be taken into
consideration when positioning generator.

A

WARNING

Generator produces hazardous voltage.

Failure to isolate generator from power utility can
result in death or injury to electric utility workers
due to backfeed of electrical energy.

• When using generator for backup power, notify utility company.

Use approved transfer equipment to isolate generator from
electric utility.

• Use a ground fault circuit interrupter (GFCI) in any damp or

highly conductive area, such as metal decking or steel work.

• DO NOT touch bare wires or receptacles.

• DO NOT use generator with electrical cords which are worn,

frayed, bare or otherwise damaged.

• DO NOT operate generator in the rain or wet weather.

• DO NOT handle generator or electrical cords while standing in

water, while barefoot, or while hands or feet are wet.

• DO NOT allow unqualified persons or children to operate or

service generator.

WARNING

Exhaust heat / gases can ignite combustibles,
structures or damage fuel tank causing a fire.

• Keep at least 5 ft. (1.5 m) clearance on all sides of generator

including overhead.

Содержание PowerBoss PowerBOSS 5600 Watt Portable Generator

Страница 1: ...Printed in U S A Manual No 197106GS Revision C 08 02 2007 5600 Watt Portable Generator Operator s Manual BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A...

Страница 2: ...for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand thes...

Страница 3: ...ures and Controls 10 Cord Sets and Receptacles 11 Operation 12 Starting the Engine 12 Connecting Electrical Loads 13 Stopping the Engine 13 Don t Overload Generator 14 Maintenance 15 Maintenance Sched...

Страница 4: ...moderate injury NOTICE indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The manufacturer cannot possibly anticipate eve...

Страница 5: ...stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WHEN ADDING OR DRAINING...

Страница 6: ...ire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed CAUTION Excessively high operating speeds increase ri...

Страница 7: ...he following tools to install these components 13 mm wrench Socket wrench with a 13 mm socket Pliers Safety glasses Install the wheel kit as follows 1 Tip generator so that engine end is up 2 Slide ax...

Страница 8: ...Altitude At altitudes over 5 000 feet 1524 meters a minimum 85 octane 85 AKI 89 RON gasoline is acceptable To remain emissions compliant high altitude adjustment is required Operation without this adj...

Страница 9: ...DO NOT place generator where exhaust gas A could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes...

Страница 10: ...and motor loads D Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area E Data Tag Provides model revision and serial number of generator Please hav...

Страница 11: ...quiring up to 5 600 watts of power 5 6 kW at 23 3 Amps for 240 Volts or two independent 120 Volt loads at 23 3 Amps each The outlet is protected by a push to reset circuit breaker 120 Volt AC 20 Amp D...

Страница 12: ...own during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil protection device If so oil must be at proper level for e...

Страница 13: ...in and turned ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push engine rocker switch to Off position 4 Move fuel valve to Off positio...

Страница 14: ...tor output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additio...

Страница 15: ...rator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or...

Страница 16: ...generator is on a level surface 2 Check oil level as described in Checking Oil Level 3 If needed slowly pour oil into oil fill opening to the point of overflowing at oil fill 4 Replace and tighten oi...

Страница 17: ...Specifications 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the recommended replacement spark plug See Specifications 5 Install spark plug and tighten firmly Servic...

Страница 18: ...ne without partial engine disassembly and the use of special tools For this reason we recommend that you have an authorized service dealer check and adjust valve clearance at recommended intervals see...

Страница 19: ...ded grade See Changing Engine Oil Oil Cylinder Bore Remove spark plug and pour about 1 2 ounce 15 ml of clean engine oil into the cylinder Install spark plug and pull starter handle slowly to distribu...

Страница 20: ...set to Off 2 Fuel Valve is in Off position 3 Dirty air cleaner 4 Out of fuel 5 Stale fuel 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in fuel 9 Flooded 10 Excessively rich f...

Страница 21: ...ur Operating and Maintenance Instructions B S recommends that you retain all your receipts covering maintenance on your small off road engine but B S cannot deny warranty solely for the lack of receip...

Страница 22: ...maintenance or repairs The owner is responsible for the performance of all required maintenance as defined in the B S Operator s Manual 6 Consequential Coverage Coverage hereunder shall extend to the...

Страница 23: ...nd apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not...

Страница 24: ...wer This difference is due to a variety of factors including but not limited to accessories air cleaner exhaust charging cooling carburetor fuel pump etc application limitations ambient operating cond...

Страница 25: ...Generador Port til de 5600 Vatios Manual del Operario BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A...

Страница 26: ...n Montaje de este manual donde encontrar instrucciones para el montaje final Siga las instrucciones al pie de la letra D nde encontrarnos Usted no tendr que ir muy lejos para encontrar el servicio t...

Страница 27: ...er sticas 10 Juegos de cordones y enchufes conectores 11 Operando 12 Encienda el motor 12 Conexi n de cargas el ctricas 13 Parada del motor 13 No sobrecargar el generador 14 Mantenimiento 15 Plan de m...

Страница 28: ...el s mbolo de alerta AVISO indica una situaci n que podr a producir da os en el equipo Siga en todo momento los mensajes de seguridad para evitar o reducir el riesgo de lesiones y de muerte El fabrica...

Страница 29: ...sirvan al generador ADVERTENCIA La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras severas e inclusive la muerte CUANDO ANADA CO...

Страница 30: ...sconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR Utilice un comprobador de buj as homologado NO comprueba la chispa sin la bu...

Страница 31: ...de ruedas conforme a las instrucciones siguientes 1 Dele la vuelta al generador de forma que el motor quede arriba 2 Introduzca el eje A a trav s de los dos soportes de montaje 3 Coloque una rueda B e...

Страница 32: ...orar Gran altitud En altitudes superiores a 1 524 metros 5 000 pies se deber utilizar gasolina con un m nimo de 85 octanos 85 AKI 89 RON Para seguir cumpliendo la normativa sobre emisiones es necesari...

Страница 33: ...puedan acumular o entrar en un edificio que pueda estar ocupado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio...

Страница 34: ...otor Indica el modelo tipo y c digo del motor Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda G Silenciador Apagachispas El silenciador disminuye el ruido del motor y est equi...

Страница 35: ...sencilla que requieren hasta 2 800 vatios de energ a a 23 3 Amperios para 120 Voltios 5 600 vatios de energ a 5 6 kW a 23 3 Amperios para 240 Voltios La salida est protegida por un corto circuito de...

Страница 36: ...seg rese de que la unidad est en una superficie plana y compruebe que el nivel de aceite del cig e al es correcto La unidad puede equiparse con un dispositivo de protecci n de bajo nivel de aceite En...

Страница 37: ...je que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador 3 Sit e el interruptor balanc n en la posici n Off 4 Gire la v lvula de comb...

Страница 38: ...cuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA a ada cargas que sobrepasen...

Страница 39: ...l motor y provocar p rdidas de rendimiento o fallos Asimismo si penetran l quidos en el generador a trav s de las ranuras del aire de refrigeraci n parte del l quido puede permanecer en los huecos y r...

Страница 40: ...aceite indicados Comprobaci n del nivel de aceite Compruebe el nivel de aceite antes de cada uso o cada 5 horas de funcionamiento como m nimo Rellene si es necesario 1 Coloque el generador sobre una...

Страница 41: ...te a mano 8 Limpie los residuos de aceite Servicio del depurador de aire Si se utiliza con un filtro de aire sucio el motor no funcionar correctamente y puede sufrir da os Cambie el filtro de aire cad...

Страница 42: ...tas especiales Por esta raz n le recomendamos que un distribuidor autorizado compruebe y ajuste la holgura de la v lvula siguiendo los intervalos recomendados consulte la secci n Plan de Mantenimiento...

Страница 43: ...grado de aceite recomendado Aceite el di metro interior del cilindro Quite la buj a y vierta aproximadamente 15 ml 1 2 onza de aceite de motor limpio en el interior del cilindro Coloque la buj a y ar...

Страница 44: ...ire sucio 4 Sin gasolina 5 Gasolina vieja 6 El cable de la buj a no est en malas la buj a 7 Buj a defectuosa 8 Agua en la gasolina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La v lvu...

Страница 45: ...sponsable de la correcta realizaci n de las operaciones de mantenimiento que se enumeran en las Instrucciones de uso y mantenimiento B S recomienda conservar todas las facturas relativas al mantenimie...

Страница 46: ...to y durabilidad equivalentes El propietario es responsable del cumplimiento de todas las operaciones de mantenimiento obligatorio que se definen en el manual del operario de B S 6 Cobertura de da os...

Страница 47: ...s sanitarios destinados al mantenimiento de las constantes vitales Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabr...

Страница 48: ...eal Esta diferencia se debe entre otros a los siguientes factores accesorios filtro de aire escape carga refrigeraci n carburador bomba de combustible etc limitaciones de la aplicaci n condiciones amb...

Отзывы: