86
Spacer Plate
Referring to Figure 7.17, remove the spacer plate from
between the crankcase and pump head, as follows:
1. If present, remove two (2) M5-0.80 x 20mm truss head
bolts along with the o-ring seal on each bolt.
2. Separate the spacer plate from the crankcase.
3. Remove the three (3) white pilot spacers.
4. Remove the three (3) piston oil seals from the pump
crankcase.
5. Remove the thermal bypass piston and the thermal bypass
spring.
6. Completely remove all traces of the head gasket from the
mating surface.
Section 7 • Large Frame Pump
Portable Pressure Washer Familiarization and Troubleshooting Guide
Figure 7.17 - Spacer Plate Removal
Item
Name
1
Thermal bypass spring
2
Thermal bypass piston & o-ring
3
Spacer plate
4
Low pressure seal
5
Pilot spacer
6
Piston oil seal (in crankcase)