![Briggs & Stratton 86262GS Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/briggs-and-stratton/86262gs/86262gs_familiarization-and-troubleshooting-manual_2811404072.webp)
If the unit is equipped with a brush/bridge rectifier (refer to
Figure 3.19), proceed as follows:
• Locate the brush/bridge rectifier inside the alternator
portion of the unit.
• Remove the DPE wires 2 & 6 (or red and blue) from
the rectifier terminals J1 and J2.
• Start the engine and get it up to running speed.
• Apply 12VDC across terminals J1 and J2. (Polarity is not
important.)
• After about five seconds, disconnect the 12VDC from
the rectifier, and stop the engine.
• Reconnect the DPE wires to the rectifier terminals.
Wire number 2 (blue) connects to J1, and wire number
6 (red) connects to J2.
• Restart the unit and check once again for proper (AC)
output voltage.
Test 3
: — Check Rotor
Little or no (AC) output voltage can be caused by a rotor
failure.
NOTE:
The voltage surge that occurs at the
moment of rotor failure can result in damage to the
bridge rectifier or voltage regulator. For that reason, if
a rotor has failed, be sure to check the bridge
rectifier, voltage regulator, or power regulator board.
Before testing the rotor, inspect the brushes and slip rings.
Replace brushes if they are worn excessively, or if they are
cracked or damaged. Do not use any metallic grit to clean
up slip rings.
To test the rotor with a volt-ohm-milliameter VOM, set the
VOM to its “OHM” scale and zero the meter.Then, test for
an open, shorted or grounded condition as follows:
•• Step 1: Checking Rotor Resistance
• Remove the brush assembly.
• Set the VOM to its “OHM” scale.
• Connect the test leads to the rotor slip rings
(See Figure 3.20).
Because of the cramped quarters inside the rear bearing
carrier, it is necessary to remove the power cable grommet
as shown in Figure 3.21.
70
Section 3 • Generator Diagnostics and Adjustments
Portable Generator Familiarization & Troubleshooting Guide
Grommet Removed
For Access
Figure 3.21 —Access To Rotor Slip Rings
Figure 3.20 — Checking Rotor Resistance
Figure 3.19 — Brush & Rectifier Combination
Содержание 86262GS
Страница 20: ...Section 1 Generator Fundamentals Portable Generator Familiarization Troubleshooting Guide 18...
Страница 56: ...54 Section 2 Generator Components Systems Portable Generator Familiarization Troubleshooting Guide...
Страница 61: ...59 Section 3 Generator Diagnostics and Adjustments Portable Generator Familiarization Troubleshooting Guide...
Страница 94: ...92 Section 3 Generator Diagnostics and Adjustments Portable Generator Familiarization Troubleshooting Guide...
Страница 110: ...108 Section 4 Generator Assemblies Portable Generator Familiarization Troubleshooting Guide...
Страница 117: ...115 Section 4 Generator Assemblies Portable Generator Familiarization Troubleshooting Guide...
Страница 118: ...116 Section 4 Generator Assemblies Portable Generator Familiarization Troubleshooting Guide...
Страница 119: ...GENERAC TORQUE TABLE Appendix A Portable Generator Familiarization Troubleshooting Guide 117...
Страница 125: ...123 Appendix A Portable Generator Familiarization Troubleshooting Guide...
Страница 126: ...Appendix A Portable Generator Familiarization Troubleshooting Guide 124...
Страница 127: ......