14 BRIGGSandSTRATTON.COM

Storage
Storage

If storing the unit for more than 30 days, use the following 

guidelines to prepare it for storage.

Long Term Storage Instructions

  1.  Clean the generator as outlined in 

Cleaning

.

  2.  Change engine oil while engine is still warm, drain oil 

from crankcase. Refill with recommended grade. See 

Changing Engine Oil

.

  3.  Treat or drain fuel from generator as fuel can become 

stale when stored over 30 days. 

Stale fuel causes acid and gum deposits to form in the fuel 

system or on essential carburetor parts. To keep fuel fresh, 

use Briggs & Stratton® Advanced Formula Fuel Treatment 

& Stabilizer, available wherever Briggs & Stratton genuine 

service parts are sold. See 

Common Service Parts.

 

There is no need to drain gasoline from the engine if a 

fuel stabilizer is added according to instructions. Run the 

engine for 2 minutes to circulate the stabilizer throughout 

the fuel system before storage.
If gasoline in the engine has not been treated with a fuel 

stabilizer, it must be drained into an approved container. 

Run the engine until it stops from lack of fuel. The use of a 

fuel stabilizer in the storage container is recommended to 

maintain freshness.

WARNING!

   Fuel and its vapors are extremely 

flammable and explosive which could cause 

burns, fire or explosion resulting in death or 

serious injury. 

•  When storing fuel or equipment with fuel in tank, store 

away from furnaces, stoves, water heaters, clothes dryers 

or other appliances that have pilot light or other ignition 

source because they could ignite fuel vapors. 

•  When draining fuel, turn generator engine off and let it 

cool at least 2 minutes before removing fuel cap. Loosen 

cap slowly to relieve pressure in tank. Drain fuel tank 

outdoors. Keep fuel away from sparks, open flames, pilot 

lights, heat, and other ignition sources. 

•  Check fuel lines, tank, cap and fittings frequently for 

cracks or leaks. Replace if necessary. 

  4.  Store generator in clean, dry area and cover with a 

suitable protective cover that does not retain moisture.

WARNING!

   Storage covers could cause a fire 

resulting in death or serious injury. 

•  Do not place a storage cover over a hot generator. Let 

equipment cool for a sufficient time before placing the 

cover on the equipment.

Содержание 030711-00

Страница 1: ...___________________________________ Serial Number _______________________________ Date Purchased _____________________________ Copyright 2015 Briggs Stratton Power Products Group LLC Milwaukee WI USA...

Страница 2: ...Description Read this manual carefully and become familiar with your outdoor generator Know its applications its limitations and any hazards involved Save these instructions for future reference The o...

Страница 3: ...jurisdiction for grounding requirements in your area Identification Label Provides model and serial number of generator Oil Drain Plug Drain engine oil here Oil Fill Cap Dipstick Check and add engine...

Страница 4: ...provided to protect the generator against electrical overload Engine Switch Set this switch to on I before starting engine Set switch to off 0 to shut off engine Low Oil Shutdown This unit is equipped...

Страница 5: ...N o t f o r R e p r o d u c t i o n 5 Features and Controls Muffler Point away from home Features and Controls...

Страница 6: ...it or taste it Even if you do not smell exhaust fumes you could still be exposed to carbon monoxide gas Operate this product only outdoors far away from windows doors and vents to reduce the risk of...

Страница 7: ...5 m from any structure overhang trees windows doors any wall opening shrubs or vegetation over 12 in 30 5 cm in height Do not place portable generator under a deck or other type of structure that may...

Страница 8: ...nk Be careful not to fill above lip This allows adequate space for fuel expansion 7 Install fuel cap and let any spilled fuel evaporate before starting engine High Altitude At altitudes over 5 000 ft...

Страница 9: ...sulting in death or serious injury NOTICE For generator output required see Generator Capacity Connect electrical loads in off position then turn on for operation 120 Volt AC 20 Amp Duplex Receptacle...

Страница 10: ...ug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the ne...

Страница 11: ...factory authorized dealer See Emissions Warranty Cleaning Daily or before use look around and underneath the generator for signs of oil or fuel leaks Clean any accumulated debris Keep area around muf...

Страница 12: ...n dipstick 4 If needed slowly pour oil into oil fill opening to the point of overflowing 5 Replace and tighten dipstick NOTICE Do not attempt to crank or start engine before it has been properly servi...

Страница 13: ...commended gap if necessary see Specifications 5 Install spark plug and tighten firmly Inspect Muffler and Spark Arrester The engine exhaust muffler has a spark arrester screen Inspect the muffler for...

Страница 14: ...must be drained into an approved container Run the engine until it stops from lack of fuel The use of a fuel stabilizer in the storage container is recommended to maintain freshness WARNING Fuel and...

Страница 15: ...gasoline engine models is labeled in accordance with SAE Society of Automotive Engineers code J1940 Small Engine Power Torque Rating Procedure and is rated in accordance with SAE J1995 Torque values...

Страница 16: ...thereafter be considered as a commercial use product for purposes of this warranty Save your proof of purchase receipt If you do not provide proof of the initial purchase date at the time warranty ser...

Страница 17: ...___________________________ N mero de serie _____________________________ Fecha de compra ____________________________ Copyright 2015 Briggs Stratton Power Products Group LLC Milwaukee WI USA Todos lo...

Страница 18: ...ustancias qu micas que seg n el estado de California pueden causar c ncer defectos de nacimiento u otros da os reproductivos ADVERTENCIA Ciertos componentes de este producto y sus accesorios correspon...

Страница 19: ...as El silenciador reduce el ruido del motor y est equipado con una pantalla de extintor de chispas Identificaci n del motor Llenado de aceite varilla del aceite Tap n de drenaje del aceite Tapa de com...

Страница 20: ...del motor Coloque este interruptor en la posici n ON I antes de arrancar el motor Coloque el interruptor en la posici n OFF 0 para apagar el motor Apagado por bajo nivel de aceite Esta unidad est equi...

Страница 21: ...N o t f o r R e p r o d u c t i o n 5 Caracter sticas y controles Mofle Ap ntelo lejos de la casa Caracter sticas y controles...

Страница 22: ...s del escape puede estar expuesto al mon xido de carbono Solo opere este producto al aire libre lejos de ventanas puertas y ventilaciones para reducir el riesgo de que el mon xido de carbono se acumul...

Страница 23: ...1 5 m 5 pies de cualquier estructura alero rboles ventanas puertas cualquier abertura de pared arbustos o vegetaci n de m s de 30 5 cm 12 in de altura No coloque el generador port til bajo una cubier...

Страница 24: ...aceite se asiente Limpie la varilla indicadora de nivel cada vez que verifique el nivel de aceite No agregue aceite en exceso 4 Reemplace y aprieta la tapa de llenado de aceite varilla indicadora de n...

Страница 25: ...erg a temporalmente usando cables prolongadores Amperaje total V lvula m nima con clasificaci n para exteriores Hasta 15m 50 pies Hasta 30m 100 pies Hasta 13A 16 14 Hasta 15A 14 12 Hasta 20A 12 10 Has...

Страница 26: ...or al aire libre 2 Conecte la primera carga preferentemente la carga m s grande 3 Permite que la salida del generador se estabilice el motor funciona con normalidad y el aparato conectado funciona bie...

Страница 27: ...or y debajo del generador en busca de signos de p rdida de aceite o combustible Limpie cualquier residuo acumulado Mantenga el rea alrededor del silenciador libre de cualquier residuo Use un cepillo d...

Страница 28: ...lentamente aceite por el orificio de llenado hasta el punto de desbordamiento 5 Vuelva a colocar la varilla y apri tela AVISO No intente arrancar el motor antes de suministrarle adecuadamente el aceit...

Страница 29: ...r de separaciones y de ser necesario restablezca la separaci n de la buj a conforme a la separaci n recomendada consulte Especificaciones 5 Instale la buj a y apriete firmemente Inspecci n del silenci...

Страница 30: ...cule por todo el sistema de combustible antes del almacenamiento Si no se ha agregado un estabilizador de combustible a la gasolina en el motor deber vaciarla completamente en un contenedor aprobado H...

Страница 31: ...e 0 6 litros 20 onzas Potencia nominal La clasificaci n de potencia bruta para modelos de motor de gasolina individual est etiquetada de acuerdo con el c digo J1940 Small Engine Power Torque Rating Pr...

Страница 32: ...rminar el per odo de garant a No es necesario el registro del producto para obtener el servicio de garant a de los productos Briggs Stratton ACERCA DE LA GARANT A El servicio de garant a solo est disp...

Отзывы: