Briggs & Stratton 030618 Скачать руководство пользователя страница 17

Not for 

Reproduction

 17

Inspect Muffler and Spark Arrester   

Figure

 

10

Inspect the muffler for cracks, corrosion, or other damage. Remove the 

spark arrester, if equipped, and inspect for damage or carbon blockage. If 

replacement parts are required, make sure to use only original equipment 

replacement parts.

Clean and inspect the spark arrester as follows:

  1.  To remove muffler guard (

A

), remove screws that connects guard to 

muffler (

B

).

  2.  Remove screws that attaches spark arrester screen (

C

) to muffler. 

Remove spark arrester screen.

  3.  Inspect screen and obtain a replacement if torn, perforated or otherwise 

damaged. DO NOT use a defective screen. If screen is not damaged, 

clean it with a brush.

  4.  Reattach screen to muffler. Reattach muffler guard.

Clean Cooling System

   

Figure

 

11

Over time debris may accumulate in cylinder cooling fins and cannot be 

observed without partial engine disassembly. For this reason, we recommend 

you have a Briggs & Stratton authorized dealer clean the cooling system (

A

per recommended intervals (see 

Maintenance Schedule

 in the 

Maintenance

 

section). Equally important is to keep top of engine free from debris. Also see 

Cleaning

.

Carburetor Adjustment

The carburetor on this engine is low emission. It is equipped with a non-

adjustable idle mixture valve. Top speed has been set at the factory. If 

adjustment is required, see a Briggs & Stratton authorized dealer.

Storage

If you will not be using the generator for more than 30 days, use the following 

guidelines to prepare it for storage.

Generator Storage

 

•  Clean the generator as outlined in 

Cleaning.

 

•  Check that cooling air slots and openings on generator are open and 

unobstructed.

Long Term Storage Instructions

Fuel can become stale when stored over 30 days. Stale fuel causes acid and 

gum deposits to form in the fuel system or on essential carburetor parts. To 

keep fuel fresh, use Briggs & Stratton Advanced Formula Fuel Treatment & 

Stabilizer, available wherever Briggs & Stratton genuine service parts are sold.
For engines equipped with a FRESH START® fuel cap, use Briggs & Stratton 

FRESH START available in a drip concentrate cartridge.
There is no need to drain petrol from the engine if a fuel stabilizer is added 

according to instructions. Run the engine for 2 minutes to circulate the 

stabilizer throughout the fuel system before storage.
If petrol in the engine has not been treated with a fuel stabilizer, it must be 

drained into an approved container. Run the engine until it stops from lack of 

fuel. The use of a fuel stabilizer in the storage container is recommended to 

maintain freshness.

Change Engine Oil

While engine is still warm, drain oil from crankcase. Refill with recommended 

grade. See 

Changing Engine Oil.

Other Storage Tips

  1.  Do Not store petrol from one season to another unless it has been 

treated as described in

 Long Term Storage Instructions.

  2.  Replace petrol container if it starts to rust. Rust and/or dirt in petrol can 

cause problems if it’s used with this unit.

  3.  Cover unit with a suitable protective cover that does not retain moisture.

  4.  Store generator in clean, dry area.

 

WARNING   

Contact with muffler area can result in serious burns. 

Exhaust heat/gases can ignite combustibles, structures 

or damage fuel tank causing a fire.

•  DO NOT touch hot parts and AVOID hot exhaust gases.

•  Allow equipment to cool before touching.

•  Keep at least 1.5 m (5 feet) of clearance on all sides of generator 

including overhead.

•  Contact the original equipment manufacturer, retailer, or dealer to obtain 

a spark arrester designed for the exhaust system installed on this engine.

•  Replacement parts must be the same and installed in the same position 

as the original parts.

 

CAUTION

   Excessively high operating speeds could result in minor 

injury. 

Excessively low speeds impose a heavy load.

•  DO NOT tamper with governor spring, links or other parts to increase engine 

speed.

•  DO NOT modify generator in any way.

 

WARNING   

Fuel and its vapors are extremely flammable and explosive 

which could cause burns, fire or explosion resulting in 

death or serious injury.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

•  Store away from furnaces, stoves, water heaters, clothes dryers or other 

appliances that have pilot light or other ignition source because they could 

ignite fuel vapors.

WHEN DRAINING FUEL

•  Turn generator engine OFF and let it cool at least 2 minutes before 

removing fuel cap. Loosen cap slowly to relieve pressure in tank.

•  Drain fuel tank outdoors.

•  Keep fuel away from sparks, open flames, pilot lights, heat, and other 

ignition sources.

•  Check fuel lines, tank, cap and fittings frequently for cracks or leaks. 

Replace if necessary.

•  DO NOT light a cigarette or smoke.

 

WARNING   

Storage covers could cause a fire resulting in death or 

serious injury.

•  DO NOT place a storage cover over a hot generator.

•  Let equipment cool for a sufficient time before placing the cover on the 

equipment.

Содержание 030618

Страница 1: ...RATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A Manual No 80007328 Revision Portable Generator Operator s Manual This generator is rated in accordance with CSA Canadian Standards Association standard C22 2 No 100 04 motors and generators ...

Страница 2: ...N o t f o r R e p r o d u c t i o n 2 BRIGGSandSTRATTON COM H B P S E C 4 M L A B C 3 D A F G 2 A D A B C G E F 1 J K R T N D ...

Страница 3: ...N o t f o r R e p r o d u c t i o n 3 3 9 A B 6 C 7 A D B A C 8 11 A 5 10 B A C ...

Страница 4: ...e thousands of Briggs Stratton authorized service dealers worldwide who provide quality service You can also find the nearest Authorized Service Dealer in our dealer locator map on the Internet at BRIGGSandSTRATTON COM Table of Contents Safe Operation Checklist 5 Operator Safety 6 Equipment Description 6 Important Safety Information 6 Assembly 8 Unpack Generator 8 Install Wheel Kit 8 Add Engine Oi...

Страница 5: ...Oil and Fuel Engine oil filled to proper level See Add Engine Oil Fuel tank filled at or below red indicator See Add Fuel Inspect fuel lines tank cap and fittings each time before using generator DO NOT use if fuel leak or damage is found Electrical When connecting to a buildings electrical system install listed transfer equipment See Connecting to a Building s Electrical System Electrical cords a...

Страница 6: ...nce is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on WARNING Generator voltage could cause electrical shock or burn resulting in death or serious injury Use approved transfer equipment to prevent backfeed by isolating generator from electric utility workers When using generator for backup power notify utility company DO NOT...

Страница 7: ...uipment marine applications or enclosure DO NOT tip engine or equipment at angle which causes fuel to spill DO NOT stop engine by moving choke control to Choke position WHEN TRANSPORTING MOVING OR REPAIRING EQUIPMENT Transport move repair with fuel tank EMPTY or with fuel shutoff valve OFF DO NOT tip engine or equipment at angle which causes fuel to spill Disconnect spark plug wire WHEN STORING FU...

Страница 8: ...ters 2 500 feet with the high altitude kit is not recommended Attach Negative Battery Cable 030620 Only Figure 3 Your unit is equipped with electric start capability but can be started manually If you choose not to use the electric start feature you do not need to connect the negative battery cable The sealed battery on the generator is pre installed except for the negative black battery cable To ...

Страница 9: ...s a buildup of CO the alarm will alert the occupants by flashing visual indicator light and alarm Smoke alarms cannot detect CO gas Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupied spaces DO NOT run this product inside homes garages basements crawlspaces sheds or other pa...

Страница 10: ...uel tank causing a fire resulting in death or serious injury Portable generator must be at least 1 5m 5 feet from any structure overhang trees windows doors any wall opening shrubs or vegetation over 30 5 cm 12 inches in height DO NOT place portable generator under a deck or other type of structure that may confine airflow Smoke alarm s MUST be installed and maintained indoors according to the man...

Страница 11: ...uld cut current off quickly enough so that a person in normal health should not suffer any serious electrical injury Test RCBO Test your RCBO every month as follows 1 While generator is running push Test T button The circuit breaker should trip handle will move to approximate center position which will disconnect power to outlets NOTICE If circuit breaker does not trip DO NOT use generator Call a ...

Страница 12: ...tion I 3 Move choke lever 4 R to choke position 4A For electric starting model 030620 only turn and hold key in start switch 4 A to start position until generator starts To prolong the life of starter components DO NOT hold key in start position for more than 5 seconds and pause for at least 1 minute between starting attempts If engine starts proceed to step 6 If engine fails to start proceed to s...

Страница 13: ...Weather Shelter 1 Using non combustible material with a fire rating of at least one hour build a shelter that will enclose three sides and the top of the generator Make sure muffler side of generator is exposed NOTICE Contact your local building material supplier for non combustible materials with a fire rating of at least one hour NOTICE Be sure shelter can easily be repositioned for change in wi...

Страница 14: ...ferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattag...

Страница 15: ...dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Cleaning Daily or before use look around and underneath the generator for signs of oil or fuel leaks Clean accumulated debris from inside and outside the generator Keep the linkage spring and other engine controls clean Keep the area around and behind the muffler free from any combu...

Страница 16: ...s 1 Make sure unit is on a level surface 2 Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug 3 Clean area around oil drain plug 4 J The oil drain plug is located at base of engine opposite carburetor 4 Remove oil drain plug and drain oil completely into a suitable container 5 Reinstall oil drain plug and tighten securely Remove oil fill cap di...

Страница 17: ...trol in the engine has not been treated with a fuel stabilizer it must be drained into an approved container Run the engine until it stops from lack of fuel The use of a fuel stabilizer in the storage container is recommended to maintain freshness Change Engine Oil While engine is still warm drain oil from crankcase Refill with recommended grade See Changing Engine Oil Other Storage Tips 1 Do Not ...

Страница 18: ...y 3 See Don t Overload Generator in Operation section 4 Contact authorized service facility 5 Clean or replace fuel filter Engine will not start shuts down when running or starts and runs rough 1 On off switch set to off position 0 2 Fuel Valve is in off 0 position 3 Low oil level 4 Dirty air cleaner 5 Clogged or dirty fuel filter 6 Out of fuel 7 Stale fuel 8 Spark plug wire not connected to spark...

Страница 19: ...period specified below it will repair or replace free of charge any part that is defective in material or workmanship or both Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser This warranty is effective for and is subject to the time periods and conditions stated below For warranty service find the nearest Authorized Service Dealer...

Страница 20: ...N o t f o r R e p r o d u c t i o n BRIGGS STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A ...

Отзывы: