Connecting Electrical Loads

Use only high quality, well-insulated extension cables with the generator’s 

230 Volt AC outlets. Inspect extension cables before each use. Check that 

all extension cables are suitably rated and are not damaged. Keep extension 

cables as short as possible to minimize voltage drop.

  1.  Let engine stabilize and warm up for a few minutes after starting.
  2.  Plug in and turn on the desired 230 Volt AC, single phase, 50 Hz 

electrical loads.

NOTICE

 

•  DO NOT connect 3-phase loads to the generator.

 

•  DO NOT connect 60 Hz loads to the generator.

 

•  DO NOT OVERLOAD THE GENERATOR. See

 Don’t Overload 

Generator.

NOTICE 

  Exceeding generators wattage/amperage capacity could damage 

generator and/or electrical devices connected to it.

•  DO NOT exceed the generator’s wattage/amperage capacity. See 

Don’t 

Overload Generator 

in the 

Operation

 section.

•  Start generator and let engine stabilize before connecting electrical loads.

•  Connect electrical loads in OFF position, then turn ON for operation.

•  Turn electrical loads OFF and disconnect from generator before stopping 

generator.

Stopping the Engine

  1.  Turn OFF and unplug 

all

 electrical loads from generator panel 

receptacles. NEVER start or stop engine with electrical devices plugged 

in and turned ON.

  2.  Let engine run at no-load for several minutes to stabilize internal 

temperatures of engine and generator.

  3.  Turn on/off switch or key in start switch to off (

0

) position.

  4.  Turn fuel valve to the off position (

0

).

Low Oil Shutdown

Check oil sensor light on control panel while pulling recoil or turning key in start 

switch if engine will not start. If the engine oil drops below a preset level, an oil 

switch will stop the engine or will not allow you to start the engine. Check oil 

level with dipstick.

If oil level is between ADD and FULL mark on dipstick:

  1.  DO NOT try to restart the engine.
  2.  Contact an authorized Briggs & Stratton service dealer.
  3.  DO NOT operate engine until oil level is corrected.

If oil level is below ADD mark on dipstick:

  1.  Add oil to bring level to FULL mark.
  2.  Restart engine and if the engine stops again a low oil condition may still 

exist. DO NOT try to restart the engine.

  3.  Contact an Authorized Briggs & Stratton Service Dealer.
  4.  DO NOT operate engine until oil level is corrected.

Cold Weather Operation   

Figure 

5

Under certain weather conditions (temperatures below 4°C [40°F] combined 

with high humidity), your generator may experience icing of the carburetor 

and/or the crankcase breather system. To reduce this problem, you need to 

perform the following:
  1.  Make sure generator has clean, fresh fuel.
  2.  Open fuel valve (turn valve to on position).
  3.  Use SAE 5W-30 oil

.

  4.  Check oil level daily or after every eight (8) hours of operation.
  5.  Maintain generator following 

Maintenance Schedule

 in 

Maintenance

 

section.

  6.  Shelter unit from elements.

Building a Cold Weather Shelter

  1.  Using non combustible material with a fire rating of at least one hour, 

build a shelter that will enclose three sides and the top of the generator. 

Make sure muffler side of generator is exposed.

NOTICE

   Contact your local building material supplier for non combustible 

materials with a fire rating of at least one hour.

NOTICE 

  Be sure shelter can easily be repositioned for change in wind 

direction.
  2.  DO NOT enclose generator any more than shown. Shelter should hold 

enough heat created by the generator to prevent icing problem.

NOTICE 

  If a wheel kit is installed on the generator, enlarge shelter 

accordingly.
  3.  Cut appropriate slots to access receptacles of unit.
  4.  Face exposed end away from wind and elements.
  5.  Locate generator as described in the section 

Generator Location

. Keep 

exhaust gas from entering a confined area through windows, doors, 

ventilation intakes or other openings.

 

WARNING   

Generator voltage could cause electrical shock or burn 

resulting in death or serious injury.

•  DO NOT connect generator to a building’s electrical system.

•  DO NOT touch bare wires or receptacles.

•  DO NOT use generator with electrical cords which are worn, frayed, bare 

or otherwise damaged.

•  DO NOT operate generator in the rain or wet weather.

•  DO NOT handle generator or electrical cords while standing in water, 

while barefoot, or while hands or feet are wet.

•  DO NOT allow unqualified persons or children to operate or service generator.

 

WARNING 

  Damaged or overloaded electrical cables could overheat, 

arc, and burn resulting in death or serious injury.

•  ONLY use suitably rated extension cables.

•  Follow all safety instructions on extension cables.

•  Inspect cables before each use.

 

WARNING   

Fuel and its vapors are extremely flammable and 

explosive which could cause burns, fire or explosion 

resulting in death or serious injury. 

•  DO NOT stop engine by moving choke control to “

Choke

” position (

).

 

WARNING   

POISONOUS GAS HAZARD. Engine exhaust contains 

carbon monoxide, a poisonous gas that could kill you in minutes. 

You CANNOT see it, smell it, or taste it. Even if you do not smell 

exhaust fumes, you could still be exposed to carbon monoxide 

gas. If you start to feel sick, dizzy or weak while using this product, shut it off 

and get to fresh air RIGHT AWAY. See a doctor. You may have carbon 

monoxide poisoning.

•  Operate this product ONLY outside far away from windows, doors and 

vents to reduce the risk of carbon monoxide gas from accumulating and 

potentially being drawn towards occupied spaces.

•  Install battery-operated carbon monoxide alarms or plug-in carbon 

monoxide alarms with battery back-up according to the manufacturer’s 

instructions. Smoke alarms cannot detect carbon monoxide gas.

•  DO NOT run this product inside homes, garages, basements, 

crawlspaces, sheds, or other partially-enclosed spaces even if using fans 

or opening doors and windows for ventilation. Carbon monoxide can 

quickly build up in these spaces and can linger for hours, even after the 

product has shut off.

•  ALWAYS place this product downwind and point the engine exhaust away 

from occupied spaces.

 13

Содержание 030618

Страница 1: ...RATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A Manual No 80007328 Revision Portable Generator Operator s Manual This generator is rated in accordance with CSA Canadian Standards Association standard C22 2 No 100 04 motors and generators ...

Страница 2: ...N o t f o r R e p r o d u c t i o n 2 BRIGGSandSTRATTON COM H B P S E C 4 M L A B C 3 D A F G 2 A D A B C G E F 1 J K R T N D ...

Страница 3: ...N o t f o r R e p r o d u c t i o n 3 3 9 A B 6 C 7 A D B A C 8 11 A 5 10 B A C ...

Страница 4: ...e thousands of Briggs Stratton authorized service dealers worldwide who provide quality service You can also find the nearest Authorized Service Dealer in our dealer locator map on the Internet at BRIGGSandSTRATTON COM Table of Contents Safe Operation Checklist 5 Operator Safety 6 Equipment Description 6 Important Safety Information 6 Assembly 8 Unpack Generator 8 Install Wheel Kit 8 Add Engine Oi...

Страница 5: ...Oil and Fuel Engine oil filled to proper level See Add Engine Oil Fuel tank filled at or below red indicator See Add Fuel Inspect fuel lines tank cap and fittings each time before using generator DO NOT use if fuel leak or damage is found Electrical When connecting to a buildings electrical system install listed transfer equipment See Connecting to a Building s Electrical System Electrical cords a...

Страница 6: ...nce is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on WARNING Generator voltage could cause electrical shock or burn resulting in death or serious injury Use approved transfer equipment to prevent backfeed by isolating generator from electric utility workers When using generator for backup power notify utility company DO NOT...

Страница 7: ...uipment marine applications or enclosure DO NOT tip engine or equipment at angle which causes fuel to spill DO NOT stop engine by moving choke control to Choke position WHEN TRANSPORTING MOVING OR REPAIRING EQUIPMENT Transport move repair with fuel tank EMPTY or with fuel shutoff valve OFF DO NOT tip engine or equipment at angle which causes fuel to spill Disconnect spark plug wire WHEN STORING FU...

Страница 8: ...ters 2 500 feet with the high altitude kit is not recommended Attach Negative Battery Cable 030620 Only Figure 3 Your unit is equipped with electric start capability but can be started manually If you choose not to use the electric start feature you do not need to connect the negative battery cable The sealed battery on the generator is pre installed except for the negative black battery cable To ...

Страница 9: ...s a buildup of CO the alarm will alert the occupants by flashing visual indicator light and alarm Smoke alarms cannot detect CO gas Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupied spaces DO NOT run this product inside homes garages basements crawlspaces sheds or other pa...

Страница 10: ...uel tank causing a fire resulting in death or serious injury Portable generator must be at least 1 5m 5 feet from any structure overhang trees windows doors any wall opening shrubs or vegetation over 30 5 cm 12 inches in height DO NOT place portable generator under a deck or other type of structure that may confine airflow Smoke alarm s MUST be installed and maintained indoors according to the man...

Страница 11: ...uld cut current off quickly enough so that a person in normal health should not suffer any serious electrical injury Test RCBO Test your RCBO every month as follows 1 While generator is running push Test T button The circuit breaker should trip handle will move to approximate center position which will disconnect power to outlets NOTICE If circuit breaker does not trip DO NOT use generator Call a ...

Страница 12: ...tion I 3 Move choke lever 4 R to choke position 4A For electric starting model 030620 only turn and hold key in start switch 4 A to start position until generator starts To prolong the life of starter components DO NOT hold key in start position for more than 5 seconds and pause for at least 1 minute between starting attempts If engine starts proceed to step 6 If engine fails to start proceed to s...

Страница 13: ...Weather Shelter 1 Using non combustible material with a fire rating of at least one hour build a shelter that will enclose three sides and the top of the generator Make sure muffler side of generator is exposed NOTICE Contact your local building material supplier for non combustible materials with a fire rating of at least one hour NOTICE Be sure shelter can easily be repositioned for change in wi...

Страница 14: ...ferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattag...

Страница 15: ...dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Cleaning Daily or before use look around and underneath the generator for signs of oil or fuel leaks Clean accumulated debris from inside and outside the generator Keep the linkage spring and other engine controls clean Keep the area around and behind the muffler free from any combu...

Страница 16: ...s 1 Make sure unit is on a level surface 2 Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug 3 Clean area around oil drain plug 4 J The oil drain plug is located at base of engine opposite carburetor 4 Remove oil drain plug and drain oil completely into a suitable container 5 Reinstall oil drain plug and tighten securely Remove oil fill cap di...

Страница 17: ...trol in the engine has not been treated with a fuel stabilizer it must be drained into an approved container Run the engine until it stops from lack of fuel The use of a fuel stabilizer in the storage container is recommended to maintain freshness Change Engine Oil While engine is still warm drain oil from crankcase Refill with recommended grade See Changing Engine Oil Other Storage Tips 1 Do Not ...

Страница 18: ...y 3 See Don t Overload Generator in Operation section 4 Contact authorized service facility 5 Clean or replace fuel filter Engine will not start shuts down when running or starts and runs rough 1 On off switch set to off position 0 2 Fuel Valve is in off 0 position 3 Low oil level 4 Dirty air cleaner 5 Clogged or dirty fuel filter 6 Out of fuel 7 Stale fuel 8 Spark plug wire not connected to spark...

Страница 19: ...period specified below it will repair or replace free of charge any part that is defective in material or workmanship or both Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser This warranty is effective for and is subject to the time periods and conditions stated below For warranty service find the nearest Authorized Service Dealer...

Страница 20: ...N o t f o r R e p r o d u c t i o n BRIGGS STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A ...

Отзывы: