57-DVRS50
15
Installation Instructions Cont.
The position of the horizontal vent termination
must be positioned in such a way as to meet all
local building codes.
Cut and frame the exterior wall to accept the
Wall Thimble. Install the Wall Thimble shield
using wood screws. If the wall being penetrated
is constructed of non-combustible material con-
crete or block wall a 8” hole sufficient for the
vent pipe is acceptable.
Venting terminals must not be recessed
into wall or siding
When the termination is to be attached to vinyl siding apply a bead of non-
hardening mastic around the outside edge to form a seal between the
standoff and the terminal. Attach the termination to the exterior wall using four wood
screws through the holes in the corners.
Complete the termination installation and apply a bead of mastic around the outer edge
of the vinyl standoff.
With the termination installed you can now connect the completed vent assembly by
sliding the unit back towards the wall and carefully inserting the pipe into the terminal.
Slide the pipe into the vent, making sure that at least 1¼” overlap between the pipe
and the termination.
N O T E
ALLOWING THE VENT PIPE TO SLOPE DOWN TOWARDS THE VENT TERMINA-
TION WILL CAUSE POOR COMBUSTION AND/OR HIGH TEMPERTURES THAT
MAY PRESENT A FIRE HAZARD.
WHEN HORIZONTAL VENTING RISE IS REQUIRED SEE VENTING CHART FOR
ACCEPTABLE VENTING CONFIGURATIONS
Fig 15-A
Fig 15-B
Horizontal Wall Vent Terminations
Standard Installation:
Built in to exterior wall
999-DV-HTCL termination
Build-in to room Installation:
Requires the
999-DV-8HTCLT termination
Standard Termination
Tall Termination
Содержание 57-DVRS50
Страница 8: ...57 DVRS50 8 APPLIANCE DIMENSIONS Surround Removed Surround Attached...
Страница 27: ...57 DVRS50 27 REMOTE CONTROL SETUP AND OPERATION future option...
Страница 28: ...57 DVRS50 28 REMOTE CONTROL SETUP AND OPERATION cont Future Option N A on this unit...
Страница 29: ...57 DVRS50 29 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 30: ...57 DVRS50 30 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 31: ...57 DVRS50 31 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 33: ...57 DVRS50 33 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 35: ...57 DVRS50 35 CONVERSION KIT INSTRUCTIONS con t Step 7 Valve Conversion...
Страница 39: ...57 DVRS50 39 WIRING SCHEMATICS Figure 25...
Страница 42: ...57 DVRS50 42 NOTES...
Страница 45: ...ARCHGARD INDUSTRIES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...