background image

200-0057 

 

April 2013 

57-DVRS50 

Gas Fired Vented Room 

Heater (Direct Vent) 

U

SERS’  

I

NSTALLATION 

O

PERATION  and 

M

AINTENANCE 

M

ANUAL 

7116 Beatty Dr 
Mission, BC V2V 6B4 
Canada 

 INSTALLER: 

Leave this manual with the appliance

CONSUMER: 

Retain this manual for future reference.

 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 

appliance. 
 

WHAT TO DO IF YOU SMELL GAS:

 

 

Do not try to light any appliance. 

 

Do not touch any electrical switch; do not use 
any phone in your building. 

 

Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions. 

 

If you cannot reach your gas supplier, call the fire 

department. 

 
Installation and service must be performed by a 
qualified installer, service agency or the gas 
supplier. 

This appliance may be installed in an aftermarket 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes. 
This appliance is only for use with the type  
of gas indicated on the rating plate. This 
appliance is not convertible for use with other 
gases, unless a certified kit is used.   

*Conversion kit required for Propane use 

WARNING: 

If the information in this manual is 

not followed exactly, a fire or explosion may 

result causing property damage, personal 

injury or loss of life. 

Tested and 
listed by 

LABTEST Certification Inc 
Richmond, British Columbia 
ANSI Z21.88-2009/CSA 2.33-2009 

SERIAL NUMBERS  510000 AND HIGHER 

Содержание 57-DVRS50

Страница 1: ...ou cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed in an...

Страница 2: ...gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the instal lation unless upon inspection the inspector observes carbon monoxide detectors and signage installe...

Страница 3: ...ighest efficiencies of any Direct Vent gas fireplace which means that it is less expensive to operate Adjustable Flame The flame aesthetics and heat output can be adjusted to suit the owner s liking a...

Страница 4: ...installation 19 Burner media Door Surround Installation 20 21 Checking Inlet Outlet pressures 22 Final Installation Check and Initial Operation 23 Lighting Instructions on Rating Plate 24 First Fire...

Страница 5: ...he control compartments burners and circulating air passageways of the appliance are kept clean Do not use this appliance if any part has been under water Immediately call a qualified service technici...

Страница 6: ...Gas Equipped Recreational vehicles and Mobile Housing CSA Z240 4 We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Fire...

Страница 7: ...both CANADA and USA Certifi pour utilisation dans le Canada et les TATS UNIS DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE TIQUETTE de s rie Serial LC Made in Canada by Fabrique au Canada par Archgar...

Страница 8: ...57 DVRS50 8 APPLIANCE DIMENSIONS Surround Removed Surround Attached...

Страница 9: ...lowing section describes the requirements for framing for the model 57 DVRS50 Note Framing should be constructed as required by local building codes 2 x 6 Framing opening in framing should be minimum...

Страница 10: ...ndoffs 0 0 Adjacent Side Wall 18 454 Room Floor From bottom of host shell 5 101 Vent Top 2 50 Vent side bottom 1 25 Front 48 1210 Room Ceiling From top of host shell 24 907 Minimum measurements below...

Страница 11: ...CL Stand off The 999 DV HTCLT termination allows the horizontal run to a maximum of 32 Use when connecting to a flexible vent system Maximum 6 Horizontal run when using the basic 999 DV HTCL Terminati...

Страница 12: ...facing into the room Install the wall thimble as shown below and seal it and the edges of the insulation board with a good quality silicone sealant to prevent cold drafts exterior wall only Figure 7...

Страница 13: ...nd the termination Installed fireplace with stand offs Figure 11 Figure 12 Figure 10 N O T E For installations straight off the back of the 57 DVRS50 the Archgard 999 DV 8HTCL termination is required...

Страница 14: ...ficient vertical height above the roof Fire stops are required at each floor level the vent passes through The following vent systems are certified for use with the model 57 DVRS50 If for any reason t...

Страница 15: ...crews through the holes in the corners Complete the termination installation and apply a bead of mastic around the outer edge of the vinyl standoff With the termination installed you can now connect t...

Страница 16: ...to an inside corner 12 30 cm Note Clear ances are to be in accordance with local installation codes and the requirements of the gas supplier G Do not install above a meter regulator assembly within 3...

Страница 17: ...flat ceiling install a Box Wall thimble Cut a 10 square hole and frame as shown in the diagram opposite Ensure all pipe sections are fully twist locked NOTE ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTA...

Страница 18: ...ation at point A you use 2 90 elbows you would be required to reduce the maxi mum horizontal from16 to 15 If 3 90 elbows were used to reach point A the maximum horizontal would be reduced from 16 to 1...

Страница 19: ...er s warranty Natural Gas Pressure Settings The inlet supply or line pressure must be a minimum of 5 W C 1 2 kPa and a maximum of 14 W C 3 5 kPa The orifices are a 35 DMS 2 73 mm drill size for the ce...

Страница 20: ...l they touch the center panel Rear Panel Installation Instructions Side Panel Baffle Installation Instructions Set the right and left side panels by inserting the tabs into the slot of the support pla...

Страница 21: ...he unit CAUTION Only doors certified with the appliance shall be used Beware the glass does not drop out Pull the bottom spring clip out and over the tabs on the bottom of the door and release as show...

Страница 22: ...e right The surround is held in place by clips buttons two at the top two at the bottom Line up the clips with the fireplace and push until it locks in You can adjust the surround by moving the bracke...

Страница 23: ...re within specs as shown on the appliance rating plate 6 Be sure to tighten the set screw inside the tap after you have completed taking pressure readings 7 Check for leaks CHECKING INLET AND OUTLET G...

Страница 24: ...nit with the customer the installer must ensure that the appliance is firing correctly and that the electrical system is in working order This will include 1 Perform leak tests of supply line gas cont...

Страница 25: ...de commande du gaz qui a t sous l eau FOR YOUR SAFETY READ BEFORE LIGHTING Pour votre s curit Veuillez lire avant d allumer WARNING If you do not follow these instructions exactly a fire of explosion...

Страница 26: ...t cover of this manual 3 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control syst...

Страница 27: ...57 DVRS50 27 REMOTE CONTROL SETUP AND OPERATION future option...

Страница 28: ...57 DVRS50 28 REMOTE CONTROL SETUP AND OPERATION cont Future Option N A on this unit...

Страница 29: ...57 DVRS50 29 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 30: ...57 DVRS50 30 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 31: ...57 DVRS50 31 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 32: ...OL SETUP AND OPERATION cont The unit is shipped from the factory with the ability for IPI CPI selection active To disable the Continuous Pilot selection ability cut one of the wires blue or white show...

Страница 33: ...57 DVRS50 33 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 34: ...is fireplace uses three orifices The two 2 outside burner orifices 57DMS propane and the center burner orifice 52DMS propane Care must be taken not to install the center orifice in an outside burner p...

Страница 35: ...57 DVRS50 35 CONVERSION KIT INSTRUCTIONS con t Step 7 Valve Conversion...

Страница 36: ...e to confirm correct operation Reinstall door assembly and surround Run through a complete firing cycle to confirm correct operation KIT NUMBERS 57 CKLP for LP gas and 57 CKNG for Natural Gas KIT INCL...

Страница 37: ...y inspect the appliance and the venting system if the vent pipe or seal is found to be defective replace and or reseal Clean and remove any lint accumulations or debris in the firebox on the burners o...

Страница 38: ...be conducted with the appliance cold All replacement parts must be authorized by Archgard Industries for suitability Before servicing read the terms and conditions of the Brigantia warranty at the bac...

Страница 39: ...57 DVRS50 39 WIRING SCHEMATICS Figure 25...

Страница 40: ...y holder 308 6014 HANDHELD REMOTE PROFLAME II Handheld remote control 308 6017 SIT 885 VALVE W STEP MOTOR Main gas valve 308 6015 SPLIT FLOW VALVE 3 8 NPT Valve for outside burners 308 6019 PSE SPARK...

Страница 41: ...ifferent gauges of steel used to manufacture your fireplace will expand and contract at different rates when your fireplace is on and will continued as your fireplace completes its heating function Yo...

Страница 42: ...57 DVRS50 42 NOTES...

Страница 43: ...the following information Model of your Fireplace Serial Number Place of Purchase Date of Purchase Problem Description NOTE Warranty may be void if work is carried out by an unqualified person s Only...

Страница 44: ...Name Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm did yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT...

Страница 45: ...ARCHGARD INDUSTRIES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: