57-DVRS50N
6
APPLIANCE CERTIFICATION
This appliance was listed by QAI Laboratories Inc to the following USA and Canadian gas
appliance standards.
-
ANSI Z21.88
-
2017/CSA 2.33
-
2017 Vented Gas Fireplace Heaters
-
CSA P.4.1
-
15 Testing method for measuring annual fireplace efficiency.
-
CSA C22.2 No.3 –
M1988(R.2014) –
Electrical Features of Fuel
-
Burning Equipment
Commonwealth of Massachusetts:
This appliance has been manufactured in accordance
with Massachusetts code 248 CMR 5.00.
Approval Code: G3
-
0119
-
103
. (http://license.reg.state.ma.us/public/licque.asp).
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of
this appliance.
INSTALLATION CODES
This appliance must be installed by a qualified gas appliance installer. The installation must
conform with the local codes or, in the absence of local codes, with the current National Fuel
Gas Code ANSI Z223.1/ NFPA 54 in the US, or Installation Code CAN/CGA
-
B149.1 in Canada.
Electrical connections and grounding must conform with local code, or current National
Electrical code ANSI/NFPA No. 70
-
1987 in the US, and in Canada the current Canadian
Electrical Code CSA C22.1.
We recommend that our gas hearth products be installed and serviced by professionals
who are certified in the U.S. by the National Fireplace Institute
®
(NFI) as NFI Gas
Specialists.
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 2000 ft. (610M) above sea level, the appliance must be
properly de
-
rated and installed according to local codes, in the absence of local codes, with the
current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CAN/
CGA
-
B149, in Canada.
Natural Gas (NG)
Propane (LP)
Manifold Pressure
1.6
-
3.5 in. W.C. (0.4
-
0.9 kPa)
6.4
-
10.0 in. W.C. (1.6
-
2.5 kPa)
Min. Supply Pressure
Max Supply Pressure
5.0 in. W.C. (1.2 kPa)
14.0 in. W.C. (3.5 kPa)
11.0 in. W.C. (2.74 kPa)
14.0 in. W.C. (3.5 kPa)
Orifice Size—Center
Orifice Size—Sides
#35 DMS (2.79 mm dia) x 1
#48 DMS (1.93 mm dia) x 2
#53 DMS (1.51 mm dia) x 1
#58 DMS (1.07 mm dia) x 2
Nominal Input Rating
21,000
-
50,000 BTU/hr
(6.1–
14.7kW)
19,000
-
50,000 BTU/hr
(5.6–
14.7kW)
P.4 Fireplace Efficiency (FE)
72.74%
72.74%
Electrical Rating
120 VAC, 60Hz less than 2 A.
120 VAC, 60Hz less than 2 A.
Gas Control
SIT 885 Proflame II
SIT 885 Proflame II
Altitude
0
-
2000 ft. (0
-
610 M)
0
-
2000 ft. (0
-
610 M)
Primary Air Opening
1/16” (3
mm) OPEN
1/4” (12
mm) OPEN
SPECIFICATIONS
Содержание 510083
Страница 4: ...57 DVRS50N 3 RATING PLATE...
Страница 8: ...57 DVRS50N 7 APPLIANCE DIMENSIONS Surround Removed Surround Attached...
Страница 27: ...57 DVRS50N 26 LIGHTING INSTRUCTIONS ON RATING PLATE...
Страница 29: ...57 DVRS50N 28 REMOTE CONTROL SETUP AND OPERATION future option SIMPLE INSTALLATION Optional handheld remote...
Страница 31: ...57 DVRS50N 30 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 32: ...57 DVRS50N 31 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 33: ...57 DVRS50N 32 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 35: ...57 DVRS50N 34 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 38: ...57 DVRS50N 37 CONVERSION KIT INSTRUCTIONS con t Step 7 Valve Conversion...
Страница 40: ...57 DVRS50N 39 WIRING SCHEMATIC Figure 25...
Страница 44: ...57 DVRS50N 43 NOTES...
Страница 45: ...57 DVRS50N 44 NOTES...
Страница 46: ...57 DVRS50N 45 NOTES...
Страница 48: ...ARCHGARD INDUSTRIES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...