57-DVRS50N
35
IMPORTANT:
This fireplace is Natural gas ready. If converting to LP gas, follow instructions below
KIT NUMBER: 57
-
CKLP for LPG
KIT NUMBER: 57
-
CKNG for NAT GAS
CONVERSION KIT INSTRUCTIONS
Step # 1
-
PREPARATION
Remove outer surround and door. Place to the side to prevent them from being damaged.
Step # 2
-
PREPARATION
Remove the angled side panels and upper baffle.
Remove side panel support plates on each side of the fireplace
Step #3
-
BURNER REMOVAL
Remove the burner media.
Remove burners by loosening and removing the wing nuts from underneath
The outer burners are removed by sliding towards the outside of the firebox and lifting out. The
center burner slides to the left and lifts out.
Step #4
-
ORIFICE CHANGE
This fireplace uses three orifices. The two (2) outside burner orifices and
the center burner orifice.
Care must be taken not to install the center orifice in an outside
burner position.
This will result in an unstable burn pattern that may
cause venting and soot problems.
Using a
1/2”
wrench remove and replace the existing orifices one at a
time. This will help prevent errors with the new orifice installation.
Step #5
-
PILOT CONVERSION
Using a
7/16”
wrench and loosen the pilot
hood 1/4 turn. Slide the tab at the bottom of
the orifice hood all the way so the red side
(propane) with the hole in it is showing.
Tighten the pilot hood back up so that it is
lined up with the two probes on both sides
of the pilot assembly.
LP has hole
and red dot
Natural Gas
Figure 22
Figure 23
WARNING:
SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE
SHUT OFF GAS SUPPLY BEFORE DISCONNECTING ELECTRICAL POWER
Содержание 510083
Страница 4: ...57 DVRS50N 3 RATING PLATE...
Страница 8: ...57 DVRS50N 7 APPLIANCE DIMENSIONS Surround Removed Surround Attached...
Страница 27: ...57 DVRS50N 26 LIGHTING INSTRUCTIONS ON RATING PLATE...
Страница 29: ...57 DVRS50N 28 REMOTE CONTROL SETUP AND OPERATION future option SIMPLE INSTALLATION Optional handheld remote...
Страница 31: ...57 DVRS50N 30 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 32: ...57 DVRS50N 31 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 33: ...57 DVRS50N 32 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 35: ...57 DVRS50N 34 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 38: ...57 DVRS50N 37 CONVERSION KIT INSTRUCTIONS con t Step 7 Valve Conversion...
Страница 40: ...57 DVRS50N 39 WIRING SCHEMATIC Figure 25...
Страница 44: ...57 DVRS50N 43 NOTES...
Страница 45: ...57 DVRS50N 44 NOTES...
Страница 46: ...57 DVRS50N 45 NOTES...
Страница 48: ...ARCHGARD INDUSTRIES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...