Page 77 of 84
040-57105-01
Figure 60: CLI Periodic Status Message
In addition, the FLEX4G-LITE sends a periodic status message when
connected. This message is sent every minute. A sample message is shown
above. This message display can be disabled using the following CLI
commands. Disabling the periodic message reduces the possibility of
mistyping.
>debug trace module level eband_radi default none
>debug trace module level eband_fpga default none
9.
The syntax for uploading the UI image uses the follow CLI
command.
>debug firmware managed.bk <ip_addr of TFTP server> <file name:
LITExxx.gz>
For example:
>debug firmware load managed.bk 10.100.7.3 LITE0004.gz
The command tells the radio software to load into the backup image memory
location the UI image available from the TFTP server located at 10.100.7.3
with the file name of FLEX4G-LITE0004.exe.
10. The radio will return the following message when the command
is executed:
Download
‘‘
<filename>
’’
, x,xxx,xxx bytes
Erasing image...
Programming image...
Periodic Status