background image

 

 

Copyright © Bridgetek Pte Ltd                

 

 

 

 

    

           7

 

 

 

 

 

PanLHub44/80 Datasheet  

Version 1.0 

 

Document Reference No.: BRT_000277    Clearance No.: BRT#146 

4

 

FCC Statements  

 

PanLHub44/80 device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions:  
 
(1) These devices may not cause harmful interference, and 
 
(2)  These  devices  must  accept  any  interference  received,  including  interference  that  may  cause 
undesired operation. 
 

NOTE:

 The equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful  interference  in  a  building  installation.  These  equipment  generates,  uses  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used in  accordance  with  the  instructions,  may  cause  harmful 
interference to radio communications. However, there is no guarantee that interference will not occur in a 
particular installation. If the equipment does cause harmful interference to radio or television reception, 
which  can be determined by turning the equipment  off and on, the  user is encouraged to try to correct 
the interference by one or more of the following measures: 
 

 

Re-orient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the  receiver  is 
connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

To maintain compliance with FCC’s RF exposure guidelines, at least 

20cm of separation distance between 

the PanLHub44/80 device and the user's body must be maintained at all times. 
 
 

 

Содержание PANL Series

Страница 1: ...t Wi Fi module if it s present in the hub Configuration and application details are available in the user guide 1 1 Features PanLHub44 80 has the following features Quad core 1 2GHz 64 bit quad core A...

Страница 2: ...00A With Wi Fi and ZigBee only PH440400A With RF433 only PH440500A With Wi Fi and RF433 only PH440600A With ZigBee and RF433 only PH440700A With Wi Fi ZigBee and RF433 Table 1 PanLHub44 Part Numbers D...

Страница 3: ...44 5 3 2 PanLHub80 6 4 FCC Statements 7 5 Hardware Features 8 5 1 Power Supply 10 5 1 1 PanLHub44 10 5 1 2 PanLHub80 10 5 2 CPU System 10 5 3 Wireless Connectivity 10 5 3 1 Wi Fi 10 5 3 2 ZigBee 10 5...

Страница 4: ...ence No BRT_000277 Clearance No BRT 146 7 Mechanical Dimensions 15 8 Contact Information 16 Appendix A References 17 Document References 17 Acronyms and Abbreviations 17 Appendix B List of Figures and...

Страница 5: ...8 x RGB LEDs POWER Input Voltage 24V DC 60W AC DC Adapter 100 240 VAC to 24V DC Power Connector 24V DC 2 5A Jack Output Voltage RJ45 4 X 24V DC 500mA RJ11 4 X 5V DC 100mA PHYSICAL CHARACTERISTICS Hous...

Страница 6: ...tch Push Switch Power Indicator LED Red LED Status Indicator LED Health Status A B 2 x RGB LEDs RJ45 Ports 8 x RGB LEDs POWER Input Voltage 24V DC 120W AC DC Adapter 100 240 VAC to 24V DC Power Connec...

Страница 7: ...requency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur...

Страница 8: ...nce No BRT_000277 Clearance No BRT 146 5 Hardware Features Figure 1 PanLHub44 Top View Figure 2 PanLHub44 Side View Ethernet Port RJ45 Ports RJ11 Ports Power Jack Power Button Reset Button Power Indic...

Страница 9: ...Document Reference No BRT_000277 Clearance No BRT 146 Figure 3 PanLHub80 Top View Figure 3 PanLHub80 Top View Figure 4 PanLHub80 Side View LED Indicator RJ45 Port 1 to Port 8 Indicator Power Indicato...

Страница 10: ...ireless devices that are required by the user Please refer to Ordering Information 2 1 and 2 2 for more details 5 3 1 Wi Fi The Wi Fi module provides an alternative option to connect to a local networ...

Страница 11: ...nLHub44 and PanLHub80 have an Ethernet port 10 100 BASE TX which can be used to connect the hub to a local network through a regular network CAT cable 5 7 RJ45 Port 5 7 1 PanLHub44 There are four RJ45...

Страница 12: ...to a PanL device and the subsequent connections between the PanL devices must not exceed 50 metres in cable length The total combined cable length must not exceed 100 metres A maximum of two PanL dev...

Страница 13: ...b Alternatively the hub can be connected to a wireless network if the Wi Fi option is present in the hub 4 Connect any PanL wired devices to the hub through the RJ45 ports or RJ11 ports Ensure that th...

Страница 14: ...146 Figure 6 PanL Hub44 80 Setup Instructions NOTE Ensure that the power cable connection and all PanL Device connections are in place before powering on the PanL Hub The user should not add or remov...

Страница 15: ...Copyright Bridgetek Pte Ltd 15 PanLHub44 80 Datasheet Version 1 0 Document Reference No BRT_000277 Clearance No BRT 146 7 Mechanical Dimensions Figure 7 PanLHub44 80 Dimensions...

Страница 16: ...formance requirements All application related information in this document including application descriptions suggested Bridgetek devices and other materials is provided for reference only While Bridg...

Страница 17: ...Acronyms and Abbreviations Terms Description ARM Advanced RISC Machine eMMC Embedded Multi Media Card FCC Federal Communications Commission IEEE Institute of Electrical and Electronics Engineers LED L...

Страница 18: ...2 PanLHub44 Side View 8 Figure 3 PanLHub80 Top View 9 Figure 4 PanLHub80 Side View 9 Figure 5 RTC Backup Battery Switch 13 Figure 6 PanL Hub44 80 Setup Instructions 14 Figure 7 PanLHub44 80 Dimensions...

Страница 19: ...No BRT_000277 Clearance No BRT 146 Appendix C Revision History Document Title PanLHub44 80 Datasheet Document Reference No BRT_000277 Clearance No BRT 146 Product Page https panl brtchip com Document...

Отзывы: