
1.3.1.2 Connection of LAN interface
Please refer 5.2 for detail connection method.
IMPORTANT INFORMATION
The network wire used for LAN connection is Straight-Through Wired Cable.
1.3.1.3 Remote control setting
Please refer 5.2. for detailed remote control setting method.
1.3.2
RS485 nterface (standard)
The RS485 interface is one of the equipment communication interfaces. It
is used for remote control and can effectively transmit signals under long-distance conditions
and in environments with high electronic noise. RS485 interface makes it is possible to connect
to local network and configure multi-drop communication link.
1.3.2.1 Location of RS485 interface
The RS485 interface is located on the rear panel of power supply (Figure 1-9
①
).
Figure 1-9 Rear panel
1.3.2.2 Connection of RS485 interface
The RS485 interface of ESA series adopts "two-wire + signal ground" wiring. In low-speed,
short-distance, non-interference occasions, ordinary twisted-pair wire can be used. Conversely,
in high-speed and long-line transmission, RS485 special cable (STP-120Ω 18 AWG) (one pair)
with impedance matching (generally 120Ω) must be used. In the environment with severe
Содержание BriPower ESA Series
Страница 1: ...BriPower ESA Series User Manual...
Страница 5: ...When the module is powered on do not touch the exposed connectors or components...
Страница 47: ...Step 4 Power off circuit breaker of the AC input side Figure 3 11 Figure 3 11...
Страница 79: ...Figure 5 25 Historical waveform panel...