39
5.1. The clocking list in detail.
Clocking list
Date: XX/XX/XX
Club
: XXXX
Race: XXXX
Time: XX:XX:XX
-----------------------------------------------------------------------------------------------------------------
Name : XXXX
Licence : XXXXXX-XX
Address : XXXXXXXXXX
Coordinate X
: XXXXXX
Postcode : XXXX
Coordinate Y
: XXXXXX
-----------------------------------------------------------------------------------------------------------------
Clock data : BRICON KSA08 LBXXXXX
Club-antenna : BRICON BN -04 X-XXXXXX
Little DUO : BRICON LDXXXXX
Set date: XX/XX/XX
Read-out date: XX/XX/XX Clock date:XX/XX/XX
time: XX:XX:XX
time: XX:XX:XX time: XX:XX:XX
Differ.: +XXX
-----------------------------------------------------------------------------------------------------------------
Timer data : XXXXXX XXXXXX XXX XXXXXX XXXXXX XXX +XXX
-----------------------------------------------------------------------------------------------------------------
Nb. El.-ring
ID-ring
Date
Timer Clocked Ev
O Y P D
1. 7a4d5380
KSA01-1234567 XXXXXX XXXXXX XXXXXX Ok
1
1. 7a4d0f13
KSA01-1234570 XXXXXX XXXXXX XXXXXX Er
2
Clocked in total: XX
(1)
membership number at the federation.
(2)
name of the race.
(3)
date of the print-out.
(4)
time of the print-out.
(5)
name and address of the fancier.
(6)
licence number of the fancier
(7)
coordinate of the fancier's loft.
(8)
type and serial number of the Electronic
Clock (EC = fancier's clock).
(8.1)
type and serial number of the DUO.
(9)
type and serial number of the basketing
antenna.
(10)
date and time of the setting.
(11)
date and time of the reading.
(12)
date and time of the EC (clock).
(13)
course of the EC during the flight (14.8 -
14.4). e.g. '-001': EC is 1 sec. slow, '+001':
EC is 1 sec. fast.
(14)
timer data.
(14.1)
date of synchronisation.
(14.2)
time of synchronisation of the mother
clock
(14.3)
time of synchronisation of the internal
timer in the EC
(14.4)
time difference between the mother
clock and the internal timer in the EC (12.2 -
12.3) when basketing
(14.5)
date of Reading
(14.6)
time of reading of the mother clock.
(14.7)
time of reading of the internal timer in
the EC.
(14.8)
time difference between the mother
clock and the internal timer in the EC when
reading (14.6 - 14.7)
(14.9)
course of the EC during the flight
(14.8 - 14.4). e.g. '-001': EC is 1 sec. slow,
'+002': EC is 1 sec. fast.
(15)
serial number, coding of the chip ring,
ring number of the pigeon, sex, date of
clocking, time of clocking, evaluation (OK =
secret code is OK, Er = secret code is wrong,
clocking must be deleted), series and
designated.
(16)
number of clockings.
(17)
signatures of the responsible person for
the club and of the fancier.
----------------------------------------------------------------------------------------------------------------
Signature
…………………..
…………………………..
…………………..
----------------------------------------------------------------------------------------------------------------
Page 1
(2)
(6)
(4)
(5)
(1)
(7)
(8)
(14)
(8.1)
(9)
(10)
(15)
(13)
(14.2)
(14.1)
(14.3)
(14.4)
(14.5)
(16)
(14.6)
(14.7)
(14.8)
(14.9)
(11)
(12)
(17)
(3)