Symptoms
Solutions
12.
The brewing cycle starts by
itself or will not shut off.
(Automatic models only.)
Test the start switch. Replace it if necessary.
Water or condensation on the timer may cause it to malfunction. Dry the timer and
retest.
Check the faucet coil fittings inside the tank for leaks. Tighten or replace these fittings
as necessary.
Test the solenoid valve for leaks. Replace it if necessary.
Test the timer. Replace it if necessary.
Check to make sure the internal wiring is correct. Inspect for loose, damaged or
overheating wires or terminals. Repair or replace wiring as necessary.
Test the incoming water supply pressure. Water pressure should be between 30 and
80 psi. Excessive water pressure can cause the valve to open or leak. If the pressure
exceeds 80 psi, install a pressure regulator and reduce pressure to 50 psi.
Water flow should enter the solenoid valve on the side marked "IN". Water entering
the valve on the wrong side may cause the valve to open or leak.
Inspect and clean the spray head, silicone tubing and siphon fittings.
13.
Parts are failing frequently.
Check to make sure the internal wiring is correct. Inspect for loose, damaged or
overheating wires or terminals. Repair or replace wiring as necessary.
Test the voltage supply. The voltage supplied should match the voltage requirement
on the electrical nameplate.
Test the wall receptacle for correct polarity.
Use only original, or authorized, replacement parts.
14.
Water leaks from the bottom
of the coffee brewer.
Inspect and clean the spray head, silicone tubing and siphon fittings.
Inspect the reservoir and reservoir tubing for blockage.
Make sure the tank cover is in place correctly and that the gaskets are in good
condition.
Do not over tighten the tank lid hold-down screw. (See #10.)
Inspect the tank and tank fittings for leaks.
The flow control washer should be .25 gpm. Incorrect flow washers may cause the
tank to overflow. (Automatic models only.)
Adjust the timer. (See #9.) (Automatic models only.)
15.
The water from the hot water
faucet comes out too fast or
too slow. (Automatic models
only.)
Adjust the faucet adjustment needle valve to approximately 5 oz. in 15 to 20
seconds. Turn the adjustment counterclockwise to increase the faucet flow,
clockwise to decrease the faucet flow.
Adjusting the faucet flow beyond recommended settings will result in rapid cooling of
the faucet flow.
Содержание 1034505
Страница 6: ...Page 6 WIRING DIAGRAM 1034505 1034506 1034520 1034521 LA 3 Automatic Coffee Brewers 120V PO ...
Страница 15: ...Page 15 PARTS DIAGRAM EXTERNAL VIEW 1034505 1034506 LA 3 Automatic Coffee Brewers ...
Страница 17: ...Page 17 PARTS DIAGRAM INTERNAL VIEW 1034505 1034506 1034520 1034521 LA 3 Automatic Coffee Brewers ...
Страница 19: ...Page 19 PARTS DIAGRAM TANK VIEW LA 3 Automatic and Pour Over Coffee Brewers ...
Страница 21: ...Page 21 PARTS DIAGRAM EXTERNAL VIEW 1034516 1034517 LA 3 Pour Over Coffee Brewers ...
Страница 23: ...Page 23 PARTS DIAGRAM INTERNAL VIEW 1034516 1034517 LA 3 Pour Over Coffee Brewers ...