Page 7
Symptoms
Solutions
2.
The coffee brewer will not
brew coffee. The lights
and warmers work, and
the coffee brewer heats.
Water must be poured in to initiate a brew cycle. Pour in
approximately 60 oz. of water for each brew cycle. See
installation instructions for correct procedures.
Inspect and clean the spray head, siphon tube and reservoir
down-tube.
3.
The coffee brewer takes
much longer than normal
to heat. The lights and
warmers work.
Test the thermostat. Replace it if necessary.
Test the voltage supply. The voltage supplied should match the
voltage requirement on the electrical nameplate.
Test the immersion element. Replace it if necessary.
Check to make sure the internal wiring is correct. Inspect for
loose, damaged or overheating wires or terminals. Repair or
replace wiring as necessary.
4.
Primary or secondary hi-
limit thermostats keep
activating.
Machine power has been left on overnight or for a long period of
time without being used. Refill tank with water and wait for
machine to reach operating temperature.
Note:
Turn machine off overnight or when not in use for a long
period of time.
Test the hi-limit thermostat. Replace it if necessary.
Test the thermostat. Replace it if necessary.
Inspect the wiring on the hi-limit thermostat for loose, damaged
or overheating wires or terminals. Repair or replace wiring as
necessary.
WARNING
Under no circumstance should the hi-limit thermostat be
by-passed. In the event of failure, the hi-limit thermostat
should be replaced. Use only original or authorized
replacement parts.
5.
The coffee brewer trips
the buildings circuit
breaker.
Too many appliances are connected on one electrical circuit.
The electrical circuit’s amperage rating may be too low. Locate
a correctly rated circuit or call an electrician to correct this
problem.
This coffee brewer may require a dedicated wall circuit. Check
the electrical specifications.
Check to make sure the internal wiring is correct. Inspect for
loose, damaged or overheating wires or terminals. Repair or
replace wiring as necessary.
Inspect the immersion element for damage. Replace it if
necessary.