background image

`

PAGE 4 

BREWBUILT.COM

LID CLAMP ASSEMBLY

  Improper assembly of the lid clamp can cause the X1 Lid to be released while under pressure, possibly resulting in injury or death.

 

When installing the lid clamp, be careful to install it according to the pictures shown here.   

 

Ensure that the lid is centered on top of the conical body during assembly. The two should be centered so that the clamp seals down evenly.

 

Lid Clamp should be hand tightened fully so there is a 5/8” gap between the ends on the 27 and 42 gallon models and a 1/8” gap on the 7 
and 14 gallon models. See assembly pictures below for proper setup.

LID GASKET ASSEMBLY

 Flip the lid upside down and install a section of the gasket, flat 

side seating into the lid groove first. Lightly push the gasket in,  
installing it in the groove as you go around the lid.

 

Please Note

, the gasket is larger than the groove to help ensure 

a tight seal during fermentation. Continue pushing the gasket 
against itself and into the lid until it is in the groove and equally 
distributed without stretch points. Once you get the first piece 
of the gasket in the groove then you can use both hands to work 
the gasket around the lid and into the groove with your thumbs. 

WARNING

GASKET 

ORIENTATION

Flat Side Into Lid Groove

GASKET INSTALLATION

With Lid Upside Down, Push Flat End Of 

Gasket Into Lid Groove

Improper assembly of the lid clamp can 
cause the X1 Lid to be released while 
under pressure, possibly resulting in 
injury or death.

Correct Lid Clamp Assembly for 27 and 42 Gallon X1 

Incorrect Lid Clamp Assembly: Backwards Arm

Incorrect Lid Clamp Assembly: Partial Engagement

Incorrect Lid Clamp Assembly: Rotated Arm

TOP VIEW

Top View

Top View

Top View

Side View

Side View

Side View

FULL
ENGAGEMENT

FULL
ENGAGEMENT

FULL
ENGAGEMENT

FULL
ENGAGEMENT

CORRECT GAP 
OF 1/8"

CORRECT  
GAP  
OF 1/8"

CORRECT  
GAP  
OF 5/8"

CORRECT GAP 
OF 5/8"

CORRECT ARM 

ROTATION

CORRECT ARM 

ROTATION

CORRECT  
ARM ROTATION

CORRECT  
ARM ROTATION

INCORRECT  
ARM ROTATION

BACKWARDS 

ARM

PARTIAL 
ENGAGEMENT

ARM  
ROTATED  
CORRECTLY BUT  
NOT FULLY ENGAGED  
IN SADDLE

Correct Lid Clamp Assembly for 7 and 14 Gallon X1 

Содержание X1 Uni Pro

Страница 1: ... Important Safety Information PAGE 5 7 General Use Features PAGE8 Connecting the Control Panel PAGE8 SettingYourTemperatures BREWBUILT COM WARNING Read entire manual for important safety information before using your BrewBuilt X1 Uni Conical Fermenter Failure to follow warnings could result in serious injury or death ...

Страница 2: ...TC clamps make sure the gasket is seated properly into both flanges Once the gasket is in place loosen the clamp so it can be fitted around the flange ends You do not need to use any tools for leverage when tightening TC clamps Hand tightening is enough for a secure leak proof connection READ AND UNDERSTAND THIS FULL MANUAL Before your first use read through this full manual and make sure you unde...

Страница 3: ...e and then work it around until barbs are fully covered THERMOWELL Place 1 5 TC Gasket and Thermowell into the open port in front of the conical just below the etched BrewBuilt Logo and fasten in place using 1 5 TC clamp SAMPLE VALVE Place 1 5 TC Gasket and Sample Valve into the open port halfway down the conical base on the front of the unit and fasten in place using 1 5 TC clamp Make sure the Sa...

Страница 4: ...tself and into the lid until it is in the groove and equally distributed without stretch points Once you get the first piece of the gasket in the groove then you can use both hands to work the gasket around the lid and into the groove with your thumbs WARNING GASKET ORIENTATION Flat Side Into Lid Groove GASKET INSTALLATION With Lid Upside Down Push Flat End Of Gasket Into Lid Groove Improperassemb...

Страница 5: ...on chamber using GENERAL USE BREWBUILT COM PAGE 5 IMPORTANT SAFETY INFORMATION Please read this entire instruction manual for important safety information prior to the use of your BrewBuilt X1 Uni Conical Fermenter GENERAL PRECAUTIONS Follow all instructions and warnings provided with cleaning agents when cleaning and sanitizing Fermenter Do not pick up Fermenter when full it is heavy and the hand...

Страница 6: ...n to clog the blow off and airlock Do not place pellet hops whole hops oak chips or other items insulation and an AC unit The downside of these options is they require more space and take longer to cool since it s cooling the fermenting wort from the outside in Either way your BrewBuilt Conical comes with a Thermowell that allows you to insert the temperature probe from a temp controller which wil...

Страница 7: ... PRV will start releasing pressure around this point Never apply more than 15 PSI to your X1 TIP Filling your keg from the bottom up will keep splashing to a minimum as beer will flow down the beverage dip tube and gently fill the keg from the bottom up Lastly pull up the PRV ring on the keg and set it in the open position to allow air or CO2 if you pre purged the keg to escape as your fresh beer ...

Страница 8: ...nly go in one way Once aligned correctly they push in and rotate clockwise 1 4 turn to lock COOLING ON POWER UP SET DOWN HEATING ON FACTORY SETTINGS tS Set Point 68 CF Celsius Fahrenheit F CA Calibration Offset 0 Pt Compressor Delay 0 dS Differential 1 To change the settings hold the S button down till tS is showing about 5 seconds Using the up and down arrows find the setting you wish to check or...

Отзывы: