background image

8 / 20

7 Before starting operation

NOTICE

Avoid connectivity disruptions!

To avoid connectivity disruptions between the devices, consider the following points before starting
operation.

1. Place base station (receiver) and remote sensor (sender) together as close as possible.

2. Set up power supply for the base station and wait until the indoor temperature is displayed.

3. Set up power supply for the remote sensor.

4. Position the base station and the remote sensor within the effective transmission range.

5. Ensure that the base station and remote sensor are assigned to the same channel.

When changing batteries always change batteries in the main unit as well as all remote units and re-
place them in the correct order, so the remote connection can be re-established. If either of the
devices is mains-powered, the power supply must be disconnected for a short moment also for this
device when exchanging the batteries. If batteries are exchanged in only one of the devices (i.e. the
remote sensor) the signal can’t be received or can’t be received correctly.

Note, that the effective range is vastly affected by building materials and position of the main and re-
mote units. Due to external influences (various RC devices and other sources of interference), the
maximum distance can be greatly reduced. In such cases we suggest to position the main unit and the
remote sensor at other places. Sometimes all it takes is a relocation of one of these components of a
few inches!

8 Setting up power supply

Base unit

1. Remove the battery compartment cover.

2. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.

3. Replace the battery compartment cover.

4. Wait until the indoor temperature is displayed on the base station.

Remote sensor

5. Remove the battery compartment cover.

6. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.

7. Move the CH slide control to the position for the desired transmission channel (setting CH1, CH2

or CH3 with screen display).

8. Replace the battery compartment cover.

NOTICE! When operating one outdoor sensor, channel 1 is recommended as the default setting.

9 Automatic time setting

After the power is restored, the unit automatically searches for the radio signal. It takes about 3-8
minutes to complete this process.

If the radio signal is received correctly, the date and time are set automatically and the reception sym-
bol is displayed.

If no radio signal is received, proceed as follows:

1. Press the DOWN button for approx. 2 seconds to initiate the reception of the radio signal again.

2. If no radio signal is still received, the time setting must be made manually.

Содержание MyTime XL

Страница 1: ...Weather Station Wetterstation MyTime XL EN Instruction manual DE Bedienungsanleitung...

Страница 2: ...le code QR ou le lien correspondant NL Bezoek onze internetpagina via de volgende QR code of weblink voor meer informatie over dit product of de beschikbare vertalingen van deze gebruiksaanwijzing ES...

Страница 3: ...English 4 Deutsch 11...

Страница 4: ...s documentation is valid for the products with the article numbers listed below 7001910000000 Manual version v1219 Manual description Manual_7001910000000_MyTime XL_en de_BRESSER_v122019a With any ser...

Страница 5: ...r a short circuit a fire or an explosion NOTICE Risk of damage to property Improper handling can result in damage to the device and or to the accessories Always observe the following safety informatio...

Страница 6: ...or increase setting values 5 DOWN button toggle between C and F or decrease setting values 6 MEM button display MIN and MAX values or delete stored values 7 Battery compartment main unit 8 Stand fold...

Страница 7: ...een display 1 Current time hours minutes seconds or alarm time AL 2 Symbol for active alarm 3 RC clock reception symbol 4 Mode dependent display Seconds or alarm time info AL 5 Indoor humidity in 6 In...

Страница 8: ...of interference the maximum distance can be greatly reduced In such cases we suggest to position the main unit and the remote sensor at other places Sometimes all it takes is a relocation of one of t...

Страница 9: ...the MODE button to confirm and switch to the next setting 6 Settings sequence Hours Minutes 7 Finally press the MODE button to save the settings and exit settings mode 8 When the alarm sounds press an...

Страница 10: ...ust be collected separately and recycled in an environmentally friendly manner Do not dispose of batteries and rechargeable batteries with the household waste You are leg ally required to return used...

Страница 11: ...hland der Europ ischen Union und oder weiteren L ndern waren mar ken und oder patentrechtlich gesch tzt 2 G ltigkeitshinweis Diese Dokumentation ist g ltig f r die Produkte mit den nachfolgend aufgef...

Страница 12: ...rien nicht kurzschlie en oder ins Feuer werfen Durch berm ige Hitze und unsachgem e Handhabung k nnen Kurzschl sse Br nde und sogar Explosionen ausgel st werden HINWEIS Gefahr von Sachsch den Bei unsa...

Страница 13: ...N Taste Wechel zwischen C und F oder Einstellungswerte verringern 6 MEM Taste MIN und MAX Werte anzeigen oder gespeicherte Werte l schen 7 Batteriefach Hauptger t 8 Standfu ausklappbar Hauptger t 9 Vo...

Страница 14: ...fangssymbol 4 Modusabh ngige Anzeige Sekunden oder Weckzeit Info AL 5 Innenraum Luftfeuchtigkeit in 6 Innentemperatur C oder F 7 Au entemperatur C oder F 8 Au ensensor Infosymbol 9 Gew hlter Sensorkan...

Страница 15: ...schieben um wenige Zentimeter 8 Stromversorgung herstellen Basisger t 1 Batteriefachdeckel entfernen 2 Batterien in das Batteriefach einsetzen Dabei die korrekte Ausrichtung der Batteriepole be achten...

Страница 16: ...lie end dr cken um Einstellungen zu speichern und den Einstellungsmodus zu verlassen 8 Bei Ert nen des Weckrufs eine beliebige Taste dr cken um den Alarm zu stoppen 12 Wettertrend Aus den gemessenen W...

Страница 17: ...ederverwertung zugef hrt werden Batterien und Akkus d rfen nicht im Hausm ll entsorgt werden Sie sind zur R ckgabe ge brauchter Batterien und Akkus gesetzlich verpflichtet und k nnen die Batterien nac...

Страница 18: ......

Страница 19: ......

Страница 20: ...ail sav bresser fr T l phone 00 800 6343 7000 BRESSER France SARL P le d Activit s de Nicopolis 260 rue des Romarins 83170 Brignoles France Prix d un appel local depuis la France ou Belgique Service N...

Отзывы: