background image

-9-

With the MC-10A controller configured to the desired
settings, the display screen should now show the
current temperature and relative humidity for the fan
controller assigned to network channel one.

► 

Temperature Display [1] and Humidity Display [12]
will show “- -” on the display screen whenever the
MC-10A Remote Interface Controller is not able to
establish communication with a fan controller on
the wireless network.

This will normally occur when

there is not enough sunlight for fan operation.
However, lack of communication may also occur when
there is too much interference or distance between the
MC-10A controller and a specific fan controller.

!

Using the Fan Button [5], cycle through the controller
network channels and verify that all installed fan
controllers on the wireless network are in
communication with the MC-10A Remote Interface
Controller. If needed, repeat this procedure in the
location where the MC-10A controller will be installed.

► 

Mount the MC-10A Remote Interface Controller in your
desired location. Slide-on screw mounts are provide
on the controller housing for your convenience.

► 

Содержание Attic Breeze

Страница 1: ...TM User Manual For use with model CS 10A CS 11A solar ventilation system controllers...

Страница 2: ...full control over the operation of your Attic Breeze solar powered ventilation products as well as many safety and performance related features Please read this user manual in its entirety before proc...

Страница 3: ...n Button Used to switch between network channels when more than one FC 10A Fan Controller is installed on the network 5 Temperature Humidity Control Button Used to access Temperature Humidity Control...

Страница 4: ...k Display May be configured for either 12 hour or 24 hour time mode 13 14 15 16 17 18 19 20 Fan Power LED Indicator Displays when controller sends power to fan 14 Solar Panel Power LED Indicator Displ...

Страница 5: ...d with controller Getting Started The Breeze Mate solar ventilation system is designed for easy installation and configuration However if you require assistance Attic Breeze is here to help Customer S...

Страница 6: ...are not designed with a 4 plug connector power cable and cannot be used with the Breeze Mate CS 10A CS 11A control systems A retrofit kit is available from Attic Breeze that may be installed to conver...

Страница 7: ...r 15 on the FC 10A Fan Controller will be illuminated If the LED indicator is not illuminated verify that the plug connectors are properly matched and secured Using the Network Channel Selector 20 ass...

Страница 8: ...Time Mode Choose either 12 hour or 24 hour time mode for clock 21 Temperature Units Choose either F or C for temperature display 22 Network Size Select the number of fan controllers installed on the...

Страница 9: ...re is not enough sunlight for fan operation However lack of communication may also occur when there is too much interference or distance between the MC 10A controller and a specific fan controller Usi...

Страница 10: ...he same time using the network s global update channel Press the On Off Button 8 to switch the fan controller to automatic mode on When configured for automatic operation the MC 10A Remote Interface C...

Страница 11: ...humidity set point targets are satisfied Temperature and humidity set points may be adjusted for each fan controller individually or all at the same time using the network s global update channel Acce...

Страница 12: ...roller will be illuminated when the selected fan is operating Operation of your Attic Breeze fan may be configured within the below set point ranges Temperature 32F 122 F 0 C 50 C Humidity 10 90 For o...

Страница 13: ...utton 7 for 10 seconds 24 26 25 AM PM If configured for 12 hour time mode select either AM or PM 24 Hours Select the current hour 25 Minutes Select the current minute 26 While in the Clock Menu use th...

Страница 14: ...l to ensure that your solar attic fan is properly installed and operating at maximum air flow performance Access the Depressurization Test Menu by holding down the Decrease Button 4 for 10 seconds 27...

Страница 15: ...l your selection is acknowledged Using the Temperature Humidity Control Button 6 acknowledge your selection and proceed to the next parameter For optimum fan performance Attic Breeze recommends beginn...

Страница 16: ...ating Due to the extreme sensitivity designed into our pressure sensing technology normal variations in the barometric pressure will be observed during testing For this reason Attic Breeze recommends...

Страница 17: ...urization alarm is acknowledged The depressurization alarm may be acknowledged by pressing the On Off Button 8 A failed test indicates that your attic may not have the proper amount of intake ventilat...

Страница 18: ...ranty Your new Breeze Mate solar ventilation system is warranted by Attic Breeze LLC to be free from defects in material and workmanship under normal use for two 2 years from the date of purchase This...

Страница 19: ...k assistance please be prepared with the following information Attic Breeze fan model number When the Attic Breeze fan was installed Dealer Installer Breeze Mate control system model number 254 865 99...

Страница 20: ...www atticbreeze net Rev 0 1 Copyright 2012 Attic Breeze LLC All rights reserved...

Отзывы: