2. Introduction 

The C3236 is a high resolution stainless steel IP68 wash-down scale ideal for general food weighing, 
portion control or checkweighing applications. This scale offers a fast weight indication along with an 
easy  to  use  Under,  Over  and  Acceptable  weight  indication.  Ideal  for  most  food  processing 
environments or where weighing needs to take place in a clean wet environment. 

 

This manual covers the introduction to the unit, its use, configuration and calibration. 

 

2.1 Unpacking 

Carefully take the scale out of 

its package, make it sure it’s not damaged and all accessories are 

included. 

 

 

Remove the scale from the carton 

 

Remove the protective covering 

 

Inspect the scale and terminal for damage 

 

Make sure all components are included: 

1. C3236 Scale 

2. Adaptor plus plug adaptors 

3. Weight Platter 

 

2.2. General Installation Guidelines 

To get the best performance from the scale try to place the C3236 in a location that will not degrade 
its accuracy. 

 

 

Avoid extremes of temperature. Try to avoid placing the scale in direct sunlight or near air vents. 

 

Place the scale on a level flat surface. Do not place the scale near vibrating machinery 

 

 

Avoid unstable power sources. Do not use near large users of electricity, e.g. welding equipment. 

 
2.3. Levelling the Scale  

Level bubble is located at the front left corner of the display.                 

 

Place the scale on a level flat surface.

 

 

 

The level bubble should be centered inside the inner ring. 

 

 

If  the  scale  is  not  level,  adjust  the  levelling  feet  until  the  level 
bubble is centered correctly.

 

 

 

Always check the level prior to using scale. 

 

2.4. Battery Operation 

To charge the 6V 4Ahr battery, plug in the supplied power adaptor into an AC power outlet and attach 
the DC wash-down connector end to the scale (Fig. 1). The scales DC water proof connector can be 
found under the scale near the battery compartment, slide back the bottom battery cover and pull out 
the DC charging lead with water proof connector and attach it to the supplied power adaptor. 
This  water  proof  connector  has  a  key  that  has  to  be  lined  up  so  it  can  only  be  plugged  in  in  one 
direction. Close the battery lid making sure the lead is not trapped and turn on the scale  
 
Please  note  the  scale  does  not  need  to  be  turned  on  to  charge  the  battery.  The  battery  should  be 
charged for at least

 

6hrs

 to fully charge the battery. 

Содержание C3236

Страница 1: ...AWT35 501815 Issue AB C3236_u_en_501815 docx Page 1 User Manual Model C3236 Checkweigher...

Страница 2: ...ntretien de routine 6 Cleaning the Machine Nettoyage de la machine 6 Sharp Objects Objets tranchants 6 2 Introduction page 7 Unpacking 7 General Installation Guidelines 7 Levelling the Scale 7 Battery...

Страница 3: ...iptions UF 12 Supervisor Menu 13 Supervisor Menu Levels 13 Supervisor Functions Descriptions LF 14 Quick Calibration Menu 15 Quick Calibration Menu Levels 15 Quick Calibration Functions Descriptions E...

Страница 4: ...AWT35 501815 Issue AB C3236_u_en_501815 docx Page 4 Manual revision history Current Issue Date Created Details of Changes Draft Jan 2019 New...

Страница 5: ...tion manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to...

Страница 6: ...operation and calibration Application and usage will determine the frequency of calibration required for safe operation PRUDENCE Le fonctionnement et l talonnage de cet quipement doivent tre v rifi s...

Страница 7: ...ht or near air vents Place the scale on a level flat surface Do not place the scale near vibrating machinery Avoid unstable power sources Do not use near large users of electricity e g welding equipme...

Страница 8: ...le please insure the power adaptor is fully removed from the scale prior to cleaning Figure 1 C3236 underside view 2 5 Front Panel Figure 2 shows the front panel of the unit It includes the display wi...

Страница 9: ...n the scale The scale will self adjust to 0 Press this key to Zero the display Press this key to Tare the weight on the scale up to 100 of capacity In Menu mode It accepts the displayed item value in...

Страница 10: ...the scale platform 4 Press the ON ZERO TARE key If the container weight is outside the Zero window area the display will show 0 000 weight and the NET annunciator is illuminated 5 Place the item to b...

Страница 11: ...RE key Press the FN key to increase the value of the flashing digit viii Press ON ZERO TARE key to complete and leave the procedure ix Press UNITS ESC key to exit the User Menu To disable the checkwei...

Страница 12: ...and increase a numeric value by pressing FN key Use ON ZERO TARE key to confirm and or move to the next option or numeric value position Press UNITS ESC key to exit the option or the menu 4 1 2 User...

Страница 13: ...Values between 01 and 99 seconds are valid UF 5 ADC Update Rate use this to select the sampling frequency 15 1 30 2 or 7 5Hz 3 See Supervisor Menu UF 6 Automatic Zero Tracking use this to define a 0 5...

Страница 14: ...a possible mechanical problem or possible load cell failure which linearity calibration may not be able to correct LF 4 ADC Update Rate use this to select the sampling frequency 15 1 30 2 or 7 5Hz 3 F...

Страница 15: ...uick Calibration Menu Levels ECF Navigate the menus and increase a numeric value by pressing FN key Use ON ZERO TARE key to confirm and or move to the next option or numeric value position Press UNIT...

Страница 16: ...to set the units range mode calibration units decimal position of the separator and division size Navigate the menus and increase a numeric value by pressing FN key Use ON ZERO TARE key to confirm and...

Страница 17: ...few divisions If large inaccuracies are recorded this indicates a possible mechanical problem or possible loadcell failure which linearity calibration may not be able to correct LF 2 CALIBRATION SETT...

Страница 18: ...number Description AWT25 502472 Power supply universal with USA UK EU plug adaptors 100 to 240VAC 50 60 Hz output 12V 1000mA with special water proof 2 pin connector Replacement battery DJW6 4 0 6V4...

Страница 19: ...AWT35 501815 Issue AB C3236_u_en_501815 docx Page 19...

Отзывы: