S A F E T Y   I N S T R U C T I O N S  

www.diaber.nl 

 

BreakAir PH-90 

 

 

Only  operate  the  hammer 

with 

recommended, 

approved  tools.  Work  with 

the 

recommended 

air 

pressure  and  avoid  heavy 

impacts. 

 

 

Do not get distracted – risk 

of  accident  is  always 

present. 

 

 

Make  sure  there  is  no 

plumbing 

or 

wiring 

(electricity, gas, ...) in place 

of operation. 

 

 

If  you  come  across  a 

foreign 

object 

while 

operating,  put  the  hammer 

aside  and  uncover  the 

object  carefully  to  identify 

it. 

 

 

If  you  cannot  produce 

sufficient  thrust  on  the 

hammer 

(e.g. 

while 

operating  horizontally  or 

upward),  choose  another 

type 

of 

machine 

or 

technology. 

Insufficient 

thrust  increases  vibrations 

and risk of injury. 

Supply hoses 

• Fire-technical properties of hoses used for supplying 
compressed air must comply with CBU Decree No. 22/1989 
Coll., § 185, section (1), as amended. 
• Supply hoses used in group I (mines) areas of higher 
explosion risk I M2 must meet requirements set by CBU 
Decree No. 22/1989 Coll., § 232, section c), as amended, 
and comply with requirements of enactments EN 1127-1 
and EN 1127-2+A1 6.4.7, EN 13 463-1 7.4.3, CSN 33 2030. 

SAFETY INSTRUCTIONS

 

As the following instructions cannot cover all possibly 
occurring cases, sound common sense must be employed 
when working with the hammer and in the vicinity of this 
machine. 

 

Do not touch the trigger until you are ready to operate. 

 

Always hold the hammer with both hands while 
operating. 

 

Stay on a safe and stable platform while operating. 

 

Do not put the hammer close to your face and do not 
rest it on your leg. 

 

Do not use your leg to push the hammer down while 
operating. The tool can break and cause serious 
injury. 

 

Stand with your legs safe out of the way of the tool 
while maintaining balance. 

 

Compressed air is dangerous! Do not aim an air hose 
at yourself or other people. Do not use pressurized air 
to clean the site or your clothing. 

 

Make sure all hose connections are firm and airtight 
and secure hoses to prevent loss of air or injury if a 
hose gets loose or bursts. 

 

Secure hoses using the prescribed number of 
recommended hose clips and sockets prescribed for 
the type of hose. 

 

Do not release any joints that are under pressure. 

 

Always switch off the air supply and bleed hoses first. 
 

 

Содержание PH-90

Страница 1: ...P N E U M A T I C P I C K H A M M E R OPERATION MANUAL PH 90 ver 10 25 2016 www diaber nl ...

Страница 2: ......

Страница 3: ...CONTENTS Obsah TABLE OF CONTENTS 1 LABOUR SAFETY WARNINGS 2 SAFETY INSTRUCTIONS 3 MATERIAL AND CONSTRUCTION 4 APPLICATION 4 TECHNICAL DESCRIPTION 5 MODEL LABELLING 5 MAINTENANCE PRINCIPLES 6 LUBRICATING 6 STORING 7 DELIVERING 7 PARTS LIST 8 AXONOMETRIE AXONOMETRIC VIEW 8 ...

Страница 4: ...use in locations of dangerous atmospheric conditions 2 category M2 group I mines The construction of the product complies with requirements of Directive 98 37 EC of the European Parliament and of the Council as amended by technical regulation Government Regulation No 24 2003 Coll as amended requirements of harmonized technical standards EN ISO 12100 standards on group I mines category M2 machinery...

Страница 5: ... of enactments EN 1127 1 and EN 1127 2 A1 6 4 7 EN 13 463 1 7 4 3 CSN 33 2030 SAFETY INSTRUCTIONS As the following instructions cannot cover all possibly occurring cases sound common sense must be employed when working with the hammer and in the vicinity of this machine Do not touch the trigger until you are ready to operate Always hold the hammer with both hands while operating Stay on a safe and...

Страница 6: ... to medium strength rock and material concrete bituminous roadways coal etc in construction works and mining or surface operations Technical data and main dimensions ISO unit PH 90 Ø25x75 PH 90 22x82 Weight kg 9 5 9 5 Impact energy J 26 Impact frequency Hz 28 Air consumption m3 min 1 1 1 Operating air pressure MPa 0 4 0 7 Effective value of weighted acceleration m s 2 9 1 Measured sound power leve...

Страница 7: ... LABELLING Machines are fitted with labels containing important information Keep these labels clean and readable at all times and order new ones as necessary The main label should be found on the handle The CE symbol states that the product is EC approved see EC Declaration of conformity Maximum permitted compressed air pressure is stated in the top right corner The opened book symbol states that ...

Страница 8: ...ssible The open screw retainer can be used for wider chisels and facilitates faster tool replacement If the hammer operates without sufficient thrust the screw retainer can crack under heavy impacts of the tool LUBRICATING The hammer must be in good condition and lubricated properly to provide maximum performance service life and proper functionality Ensure sufficient lubrication with an oiler or ...

Страница 9: ...d a certificate of warranty By default we deliver the Quick Coupling as the joint for the supply hose Alternatively the quick coupling can be replaced by a cap nut with a socket which can be attached to the threaded socket The cap nut item no 319 257 can be combined with Ø13 socket item no 319 264 Ø16 socket item no 319 255 Ø20 socket item no 319 256 Following items are also for sale tools oilers ...

Страница 10: ...J 19 273 406 Silencer 1 J 20 4771 050 Safety Ring 1 J 21 8040 140 Handle Assy 1 N 22 5259 483 Handle 1 J 23 1411 172 Trigger 1 J 24 311 038 Spring Pin 8 x 28 1 J 25 722 094 Ball 17 plastic 1 J 26 315 007 Spring 4500 240 1 J 27 311 376 Plug 1 J 28 319 282 Threaded Socket G 3 4 3 4 1 J 29 414 259 Quick Coupling 3 4 1 J 30 3081 271 Trigger Pin 1 J 319 264 Socket Js 13 1 N 31 316 255 Socket Js 16 1 N ...

Страница 11: ......

Страница 12: ...AXONOMETRIE AXONOMETRIC VIEW PARTS LIST PAGE 8 BreakAir PH 90 ...

Отзывы: