Page 4
The following operations and conditions must be functionally verified in order for the lift to be FMVSS
403/404 compliant. If an operation does not function as described or a condition is not met, follow the refer
-
enced procedures to correct the problem or contact a BraunAbility Aftersales representative.
• Vehicle movement is prevented unless the lift door is closed, ensuring the lift is stowed.
1. Verify on the pump module mounted interlock connecter that the lift stowed signal - pin 9 has a
ground signal OR lift not stowed signal - pin 5 has an open signal (depends on interlock used).
2. Refer to the interlock installation instructions.
• Lift operation shall be prevented unless the vehicle is stopped and vehicle movement is prevented.
1. Verify vehicle secure signal (pin 6) has a +12 volt signal.
2. Refer to the interlock installation instructions.
• The platform will not fold/stow if occupied.
- Refer to Platform Fold Pressure Adjustment procedures.
• The inner roll stop will not raise if occupied.
- Call
BraunAbility Aftersales.
• The outer barrier will not raise if occupied.
- Refer to Outer Barrier Fold Pressure Adjustment procedures.
• Verify platform lighting when lift is deployed and pendant illumination when lift is powered.
1. Replace bulb(s) in the light housing.
• A warning will activate if the threshold area is occupied when the platform is at least 1" below floor level.
1. Remove the threshold warning plate.
2. Verify the threshold strip switch connector is securely connected.
3. Reinstall threshold warning plate.
4. Test threshold warning (push down on plate). If warning is not activated, see Step 5.
5. Remove the threshold warning plate and replace non-functioning threshold switch.
6. Repeat Step 4. If warning is still not activated, call BraunAbility Aftersales.
• Platform movement is prohibited beyond the position where the inner roll stop is fully deployed (up).
- Call
BraunAbility Aftersales
.
• Platform movement shall be interrupted unless the outer barrier is deployed (up).
- Call
BraunAbility Aftersales
.
Certification Checklist Diagnostic Procedures
Содержание Century 2
Страница 11: ...Page 9 NOTES This page intentionally left blank...
Страница 37: ...Page 35 NOTES This page intentionally left blank...