14
Manual C118 EN Rev04
04.2017
14
Programming the C118
List of Program Steps (effective only in VAR mode)
Step Function handled
Page
00
minimum measuring time, determines sequence (by steps)
15
01
maximum measuring time, determines low speed (by steps)
15
02
Computing factor:
multiplying mode = parameter 0
dividing
mode
=
parameter
1
16
03
Computing factor:
number of factor decimals
16
04
Computing factor:
numerical value of factor
16
05
Speed display readings position of decimal point
16
06
Analog output
reading assigned to high end
17
07
Analog output
reading assigned to low end
18
08
Automatic power off parameter 0 = no, 1 = after 10 min
18
09
Input frequency divider factor (001…255)
18
10
Totalizing function
position of decimal point at SF
19
Programming Procedure
Note: Programming can be done in both modes FIX and VAR.
Programmed characteristics however get valid in VAR mode only.
In FIX mode, all functions are as listed on page 5.
Press key PROG to enter the programming phase. Step 00 appears blinking. To
enter a higher or lower step, use keys
,
or.
.
The thus addressed program No.
blinks.
When in the desired step (see list of steps above or at bottom of the instrument),
use key to enter the parameter. Numerical parameters are set digit by digit,
starting at the right end digit. The one addressed blinks. Select higher or lower
values by the keys , or . Move to the next digit to the left by key , and set
this accordingly. With parameters to be set step by step, or as decimal point po-
sition, use to move it. When the parameter is properly set, touch key PROG to
acknowledge, and move to next program step. Set it, following the same proce-
dure. Before leaving a step, acknowledge by PROG.
To leave the programming phase touch key PROG again.
Note: all parameters are kept safe, when the unit is switched off.