Universal Hand Held Tachometer 

MOVIPORT C118 Series

Manual

Hand Held Tachometer C118 + Cable SAK-2m + Sensor A1S30P95

Содержание MOVIPORT C118 Series

Страница 1: ...Universal Hand Held Tachometer MOVIPORT C118 Series Manual Hand Held Tachometer C118 Cable SAK 2m Sensor A1S30P95...

Страница 2: ......

Страница 3: ...put Response 11 MAX MIN Memory 12 Totalizing Function 12 FIX VAR Operation Modes 13 Programming Procedure and List of Steps 14 Parameter Functions Shortest and Maximum Measuring Time Allowance 15 Comp...

Страница 4: ...6P95 with 5m firmly attached cable in place of A1S30P95 SAK 2m Equipment otherequipment as under C118 2BS C118 3BP Instrument with RS232 Data Interface and adapter cable L3D01 otherequipment as under...

Страница 5: ...able position VAR mode Memory Maximum Minimum Average over a controllable period of time Call to display by push button Signal Input To pulses or AC voltage from 50 mVeff up to 60 volts Selection of a...

Страница 6: ...sitivity C118 2 and C118 3 only Jack to supply unit U1H008 Display reading measurements with their time reference operating mode pro gram Step No and its parameter Key board to select the functions se...

Страница 7: ...gramming procedure and function in structions start on page 14 plug in sensor immediately into socket or use connection cable For normal operation use predetermined automatic mode Manual knob preset a...

Страница 8: ...ape U1A006 A1S37P Sensing wheel twin type wheel 63 mm 1000 pulses meter for length detection Speed measuring range 0 1200 m min A1L04B200 Sensing wheel twin type wheel 159 mm 1000 pulses meter for len...

Страница 9: ...faster reaction at a slow motion they should be placed with equal distances be tween them The acceptable scanning distance clearance widely de pends on the contrast of the mark In general it will be 0...

Страница 10: ...range from 40 C 125 C Magnetic induction type sensors are active but limited to rather high speed as in turbo blower engines Further to detect AC magnetic fields as in the neighborhood of igni tion co...

Страница 11: ...ccepts the other sensors see page 6 too Please observe the guiding slot at the socket The screw at the connector will be downside For other signal sources the ready made cable L2A12PS 2m may be used o...

Страница 12: ...wered by batteries cells or from mains by supply unit Battery replacement Power ON OFF The ON OFF key switches power to the instrument Further it may be programmed to automatically switch off by itsel...

Страница 13: ...adjustment of the maximum sensitivity Model Nos C118 2 and C118 3 only The fast automatic signal conditioning might lose its cor recting function when the signal frequency drops below ap proximately 1...

Страница 14: ...Base of Readings The facility of the C118 converts the originally measured signal frequency into readings with a corresponding time base as indicated at the display Select desired time base by the key...

Страница 15: ...ill be main tained with decreasing measurements Return to the initial decimals sequence by switching the instrument off on Totalizing SF may be used counting the input pulses not scaled but reduced by...

Страница 16: ...in both modes FIX and VAR Programmed characteristics however get valid in VAR mode only In FIX mode all functions are as listed on page 5 Press key PROG to enter the programming phase Step 00 appears...

Страница 17: ...ly by keys or Step No 00 minimum measuring time allowance determines tracking sequence but also steadiness of readings Maximum time allowance for one measurement This program step sets a limit to the...

Страница 18: ...the di viding factor Set parameter of step 02 to 1 to achieve the dividing mode Determining the relation between measurement and reading Step No 02 Mode of computing factor 0 multiplying 1 dividing D...

Страница 19: ...tput High End 4 volts Assignment of the Analog Output The parameter defines the displayed value assigned to the high end 4 volts of the output however it may be achieved disregarding the s min h refer...

Страница 20: ...tion will divide the incoming pulse rate accordingly This returns the pulse se quence to one pulse per revolution what obviously ensures the most accurate repetition as the best basis for stable measu...

Страница 21: ...Minimum Time Allowance 0 50 s 01 Maximum Time Allowance 8 00 s 02 Computing Factor Mode 0 multiplying 03 decimals none 04 numerical 000001 05 Display decimals none 06 Analog Output high end 010000 07...

Страница 22: ...d results or sent only once after request Transmission Request message syntax STX n H z ETX The type of measurement required is defined by a figure n in the syntax n 1 actual most recent measurement 2...

Страница 23: ...de 02 ETX end of text in HEX code 03 CR carriage return in HEX code 0D Connection cable L3D01 and Data Port Connector type of cable L3D01 USB Mini B male to 9 pole SUB D male pin No signal 2 RxD m 3 T...