Braun ExactFit 3 Скачать руководство пользователя страница 5

3

Thank you for purchasing the Braun ExactFit 3 Blood Pressure Monitor.
Your new blood pressure monitor uses the oscillometric method of blood pressure measurement.  

This means the monitor detects blood movement through your brachial artery and converts the 

movements into a digital reading. An oscillometric monitor does not need a stethoscope, so the 

monitor is simple to use.

Intended use of Braun ExactFit™ 3

This device is a digital blood pressure monitor intended for measuring the blood pressure and pulse 

rate of adults. The device detects the appearance of irregular heartbeats during measurement and 

gives a warning signal with the measurement result, if detected.
The Braun ExactFit 3 Blood Pressure Monitor has been developed for accurate and comfortable blood 

pressure measurements. The measuring accuracy was tested at the time of manufacture and was 

proven by clinical research in accordance with the ESH IP-2002 and ANSI / AAMI SP-10-2002.

What you should know about blood pressure

Blood pressure constantly changes throughout the day. It rises sharply in the early morning and 

declines during the late morning. Blood pressure rises again in the afternoon and finally drops to 

a low level at night. Also, it may vary in a short period of time. Therefore, readings from successive 

measurements can fluctuate.
This device will display your blood pressure reading referring to two values: systolic and diastolic. 

The systolic blood pressure (the upper number) indicates how much pressure your blood is exerting 

against your artery walls when the heart beats. The diastolic blood pressure (the lower number) 

indicates how much pressure your blood is exerting against your artery walls while the heart is resting 

between beats. The pulse value is also displayed after each measurement. 
Blood pressure measured in a doctor’s office only provides a momentary value. Repeated 

measurements at home better reflect one’s actual blood pressure values under everyday conditions.
Moreover, many people have a different blood pressure when they measure at home, because they 

tend to be more relaxed than when in the doctor’s office. Regular blood pressure measurements taken 

at home can provide your doctor with valuable information on your normal blood pressure values 

under actual «everyday» conditions.
The AHA (American Heart Association) have set up the following standard blood pressure values when 

measured with a resting pulse at home:

*LCD display text and icons flash for Hypertensive Crisis reading

English

Blood pressure 

(mmHg)

Normal

Elevated

High Blood Pressure 

Stage 1

High Blood Pressure 

Stage 2

Hypertensive Crisis

SYS = systole  

(upper value)

Less than 120 120-129

130-139

140-180

higher than 180

DIA = diastole  

(lower value)

Less than 80

Less than 80

80-89

90-120

higher than 120

140-180

90-120

130-139

80-89

120-129

< 80
< 80

 < 120

and 
and

or
or

SYS

(mmHg)

DIA

(mmHg)

180+

120+

and/or

Green >

Yellow >

Orange >

Red >

Flashing Red >

If you are under medical treatment or taking  
any medication, please consult your doctor first. 
DO NOT adjust medication based on 
measurement results from this blood pressure 
monitor. Take medication as prescribed by your 
doctor. Only a doctor is qualified to diagnose 
and treat high blood pressure. 

Содержание ExactFit 3

Страница 1: ...BUA6150...

Страница 2: ......

Страница 3: ...g 1a and Fig 1b 1 Start button 2 Memory buttonM 3 Date time adjust button 4 Set button 5 Average button 6 User A B switch 7 LCD display 8 Hose port 9 Connector 10 Arm cuff supplied with 2 cuffs 11 Air...

Страница 4: ...7 8 Product description cont See page 1 2 Fig 1a and Fig 1b Fig 1b 7 LCD display 8 Hose port 9 Connector 10 Arm cuff supplied with 2 cuffs 11 Air hose 12 Battery compartment cover 4 X 1 5V type AA LR...

Страница 5: ...is exerting against your artery walls when the heart beats The diastolic blood pressure the lower number indicates how much pressure your blood is exerting against your artery walls while the heart i...

Страница 6: ...V shunt is present This can cause temporary interference of blood flow and potential injury to the user DO NOT apply the cuff over a wound as this can cause further injury DO NOT use the device while...

Страница 7: ...the metal ring to a loop The smooth cloth should be on the inside of the cuff 2 Plug the air hose into the connector Fig 5 3 If the cuff is located correctly the velcro will be on the outside of the c...

Страница 8: ...according the American Heart Association AHA For every measurement displayed on the screen the cursor will indicate the blood pressure level with the corresponding color code from green to red You ca...

Страница 9: ...shown for 2 seconds Air pressure will automatically pump up to certain pressure level and start measurement Do not move or talk in the midst of taking blood pressure measurement During the measurement...

Страница 10: ...display it means the battery is low and all four batteries need to be replaced with alkaline LR6 AA batteries After replacing batteries ExactFit 3 will go into time setting mode automatically and sho...

Страница 11: ...or moving during measurement Check if posture is correct E1 shows The cuff is not secure Refasten the cuff and then measure again E2 shows The cuff is very tight Refasten the cuff and then measure aga...

Страница 12: ...low The customer or the user of the BUA6150 should ensure that it is used in such an environment The BUA6150 equipment is intended for use in the electromagnetic environment specified below The custom...

Страница 13: ...11 English...

Страница 14: ...f Whenever not used for 1 minute Accessories 4 batteries 2 arm cuffs with tube instruction manual travel bag Service life 5 years The BUA6150 was clinically investigated according to the ESH IP 2002 a...

Страница 15: ...The LOT and SN of your device are printed on the rating label on the back of the product Production date is given by the LOT located in the back of the device The first 3 numeric digits after the LOT...

Страница 16: ...14...

Страница 17: ...icio 2 Bot n de memoriaM 3 Bot n de ajuste de fecha hora 4 Bot n de ajuste 5 Bot n de promedio 6 Interruptor de usuario A B 7 Pantalla LCD 8 Conector de la manguera 9 Conector 10 Manguito suministrado...

Страница 18: ...ducto cont Consulte las p ginas 15 16 Fig 1a y Fig 1b Fig 1b 7 Pantalla LCD 8 Conector de la manguera 9 Conector 10 Manguito suministrado con 2 manguitos 11 Manguera de aire 12 Tapa del compartimiento...

Страница 19: ...ra las paredes arteriales cuando el coraz n late La presi n arterial diast lica el n mero inferior indica cu nta presi n ejerce la sangre contra las paredes arteriales mientras el coraz n descansa ent...

Страница 20: ...puede causar interferencia temporal del flujo sangu neo y lesiones potenciales para el usuario NO coloque el manguito sobre una herida ya que esto puede causar m s lesiones NO use el dispositivo mien...

Страница 21: ...metal hasta el bucle La parte suave de la tela debe estar en la parte interior del manguito 2 Conecte la manguera de aire en el conector Fig 5 3 Si el manguito est bien colocado el velcro estar en la...

Страница 22: ...indicador de nivel de presi n arterial establecido de acuerdo con la Asociaci n Estadounidense del Coraz n AHA Para cada medici n mostrada en la pantalla el cursor indicar el nivel de presi n arterial...

Страница 23: ...suelteelbot ndeinicio 1 semostrar ntodoslosiconosenpantalladurante2segundos Lapresi ndelairebombear autom ticamentehastaciertoniveldepresi neiniciar lamedici n No se mueva ni hable durante la medici n...

Страница 24: ...indicador de pila baja parpadea en la pantalla indica que las pilas est n gastadas y es necesario reemplazar las cuatro pilas con pilas alcalinas LR6 AA Despu s de reemplazar las pilas el ExactFit 3 e...

Страница 25: ...a postura es correcta E1 indica El manguito no est bien colocado Vuelva a ajustar el manguito y repita la medici n E2 indica El manguito est demasiado apretado Vuelva a ajustar el manguito y repita la...

Страница 26: ...24 El cliente o el usuario del BUA6150 debe asegurarse de que se utilice en dicho entorno El cliente o el usuario del equipo BUA6150 deben asegurarse de que se utiliza en dicho entorno...

Страница 27: ...aci n de pulsos Modulaci n de pulsos Modulaci n de pulsos LTE Banda 7 LTE Banda 5 LTE Banda 13 17 LTE Banda 1 3 Modulaci n de pulsos Para algunos servicios s lo se incluyen las frecuencias de subida L...

Страница 28: ...o autom tico Siempre que no se use por 1 minuto Accesorios 4 pilas 2 manguitos con tubo manual de instrucciones bolsa de viaje Vida til 5 a os El BUA6150 fue investigado cl nicamente de acuerdo con la...

Страница 29: ...umerRelations HelenofTroy com El LOTE y SN No de serie de su dispositivo est n impresos en la etiqueta de clasificaci n en la parte posterior del producto La fecha de producci n se obtiene del LOTE ub...

Страница 30: ...Kaz USA Inc A Helen of Troy Company 400 Donald Lynch Blvd Suite 300 Marlborough MA 01752 Contact Us Questions or Comments Call us toll free at 1 800 327 7226 eMail ConsumerRelations HelenofTroy com Vi...

Отзывы: